Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Heart Lung Circ ; 25(7): 668-75, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26906283

RESUMO

BACKGROUND: Technological advancements in newer-generation catheterisation laboratories may reduce patient and occupational radiation exposure. METHODS: We compared fluoroscopy time and dose-area product (DAP) between a Philips Allura X-PER FD20 and Siemens Artis Zeego Hybrid systems for 47 single-vessel percutaneous coronary interventions (PCI) and 35 transcatheter aortic valve implantations (21 Corevalve, 14 Edwards Sapien TAVI) using the FD20, versus 30 PCI and 28 TAVI (15 Corevalve, 13 Sapien) with the Zeego over a 24-month period. RESULTS: Multivariate analysis revealed that, adjusting for patient weight and fluoroscopy time, DAP (median, interquartile range) was 26% lower for PCI with the Zeego than the FD20 [55.6 (27.0-91.5) vs 77.6 (51.2-129.1) Gy.cm(2), P=0.03)] and using tomographic imaging with the Zeego did not increase DAP for TAVI procedures [98.1 (65.9-136.6) vs 112.4 (64.9-156.2) Gy.cm(2) (P=NS). Although fluoroscopy times were longer for TAVI procedures than PCI with both systems (23.5-24.4 vs 7.3-9.2mins, p<0.0001), there was a significant difference in DAP between PCI and combined TAVI with the Zeego (55.6 vs 112.4Gy.cm(2), P<0.006) but not with the FD20 (77.6 vs 98.1Gy.cm(2), P=NS). CONCLUSION: Specific dose-reducing features of the new-generation system reduced DAP more for PCI than TAVI, as valve replacement procedures use additional cine-acquisition not necessary for PCI.


Assuntos
Intervenção Coronária Percutânea/métodos , Doses de Radiação , Tomografia por Raios X/instrumentação , Tomografia por Raios X/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Feminino , Fluoroscopia/instrumentação , Fluoroscopia/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
3.
Heart Lung Circ ; 23(11): 1075-83, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24973863

RESUMO

BACKGROUND: With the increased application of structural heart intervention techniques, there is concern over increasing radiation dose, especially during lengthy procedures. METHODS: We compared data from 91 consecutive single-vessel percutaneous coronary interventions, 69 patent foramen ovale closures, 25 atrial septal defect closures, 49 percutaneous transluminal mitral valvuloplasties, 57 balloon aortic valvuloplasties, 53 trans-catheter aortic valve implantations (TAVI), 21 left atrial appendage occlusions and 7 MitraClip procedures. RESULTS: The following fluoroscopy times and dose-area product (median, interquartile range) were recorded: patent foramen ovale closure (7.8, 5.3-10.9 minutes; 16.9, 7.5-30.6 Gycm(2)), atrial septal defect closure (10.1, 7.3-13 minutes; 15.5, 11.6-30.5 Gycm(2)), percutaneous transluminal mitral valvuloplasty (14.3, 11.4-24.2 minutes; 37.4, 19.8-87.0 Gycm(2)), balloon aortic valvuloplasty (8.4, 5.2-13.2 minutes; 19.8, 10.2-30.0 Gycm(2)), Edwards Sapien TAVI (24.0, 19.3-34.4 minutes; 86.4, 64.0-111.4 Gycm(2)), Medtronic CoreValve TAVI (19.4, 15.0-26.0 minutes; 101.9, 52.6-143.2 Gycm(2)), left atrial appendage occlusion (18.5, 15.7-29.1 minutes; 84.1, 36.4-140.0 Gycm(2)), Mitraclip procedures (37.2, 14.2-59.9 minutes; 89.1, 26.2-118.7 Gycm(2)), coronary angiography and single vessel percutaneous coronary intervention (6.6, 5.1-11.0 minutes; 62.5, 37.0-95.8 Gycm(2)). CONCLUSION: For structural heart interventions, dose-area product was not significantly greater than for coronary angiography with single-vessel percutaneous coronary artery intervention. This should be reassuring to patients and staff attending prolonged structural heart interventions.


Assuntos
Valvuloplastia com Balão , Angiografia Coronária , Cardiopatias , Intervenção Coronária Percutânea , Doses de Radiação , Substituição da Valva Aórtica Transcateter , Idoso , Cardiopatias/diagnóstico por imagem , Cardiopatias/cirurgia , História Antiga , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...