Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 17(11)2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38893753

RESUMO

In this study, Silicon Carbide (SiC) nanoparticle-based serigraphic printing inks were formulated to fabricate highly sensitive and wide temperature range printed thermistors. Inter-digitated electrodes (IDEs) were screen printed onto Kapton® substrate using commercially avaiable silver ink. Thermistor inks with different weight ratios of SiC nanoparticles were printed atop the IDE structures to form fully printed thermistors. The thermistors were tested over a wide temperature range form 25 °C to 170 °C, exhibiting excellent repeatability and stability over 15 h of continuous operation. Optimal device performance was achieved with 30 wt.% SiC-polyimide ink. We report highly sensitive devices with a TCR of -0.556%/°C, a thermal coefficient of 502 K (ß-index) and an activation energy of 0.08 eV. Further, the thermistor demonstrates an accuracy of ±1.35 °C, which is well within the range offered by commercially available high sensitivity thermistors. SiC thermistors exhibit a small 6.5% drift due to changes in relative humidity between 10 and 90%RH and a 4.2% drift in baseline resistance after 100 cycles of aggressive bend testing at a 40° angle. The use of commercially available low-cost materials, simplicity of design and fabrication techniques coupled with the chemical inertness of the Kapton® substrate and SiC nanoparticles paves the way to use all-printed SiC thermistors towards a wide range of applications where temperature monitoring is vital for optimal system performance.

2.
Sci Rep ; 11(1): 3393, 2021 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-33564062

RESUMO

Photonic curing has shown great promise in maintaining the integrity of flexible thin polymer substrates without structural degradation due to shrinkage, charring or decomposition during the sintering of printed functional ink films in milliseconds at high temperatures. In this paper, single-step photonic curing of screen-printed nickel (Ni) electrodes is reported for sensor, interconnector and printed electronics applications. Solid bleached sulphate paperboard (SBS) and polyethylene terephthalate polymer (PET) substrates are employed to investigate the electrical performance, ink transfer and ink spreading that directly affect the fabrication of homogeneous ink films. Ni flake ink is selected, particularly since its effects on sintering and rheology have not yet been examined. The viscosity of Ni flake ink yields shear-thinning behavior that is distinct from that of screen printing. The porous SBS substrate is allowed approximately 20% less ink usage. With one-step photonic curing, the electrodes on SBS and PET exhibited electrical performances of a minimum of 4 Ω/sq and 16 Ω/sq, respectively, at a pulse length of 1.6 ms, which is comparable to conventional thermal heating at 130 °C for 5 min. The results emphasize the suitability of Ni flake ink to fabricate electronic devices on flexible substrates by photonic curing.

3.
Sensors (Basel) ; 19(3)2019 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-30678200

RESUMO

Printed electronic devices are attracting significant interest due to their versatility and low cost; however, quality control during manufacturing is a significant challenge, preventing the widespread adoption of this promising technology. We show that terahertz (THz) radiation can be used for the in situ inspection of printed electronic devices, as confirmed through a comparison with conventional electrical conductivity methods. Our in situ method consists of printing a simple test pattern exhibiting a distinct signature in the THz range that enables the precise characterization of the static electrical conductivities of the printed ink. We demonstrate that contactless dual-wavelength THz spectroscopy analysis, which requires only a single THz measurement, is more precise and repeatable than the conventional four-point probe conductivity measurement method. Our results open the door to a simple strategy for performing contactless quality control in real time of printed electronic devices at any stage of its production line.

4.
Adv Physiol Educ ; 26(1-4): 129-32, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12031945

RESUMO

A simple, noninvasive, and economical home-made respirometer has been used to determine the standard metabolism of goldfish. The apparatus has been tested on several fishes and has proved its accuracy in determining a mass effect on standard metabolism. The apparatus can be made easily by middle school, high school, and undergraduate students and can be used to introduce them to basic concepts in animal physiology and in biological statistics.


Assuntos
Carpa Dourada/metabolismo , Fisiologia/instrumentação , Animais , Constituição Corporal , Custos e Análise de Custo , Desenho de Equipamento , Modelos Biológicos , Consumo de Oxigênio , Fisiologia/economia , Respiração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...