Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(10)2023 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-37430727

RESUMO

Optical fiber sensors (OFSs) represent an efficient sensing solution in various structural health monitoring (SHM) applications. However, a well-defined methodology is still missing to quantify their damage detection performance, preventing their certification and full deployment in SHM. In a recent study, the authors proposed an experimental methodology to qualify distributed OFSs using the concept of probability of detection (POD). Nevertheless, POD curves require considerable testing, which is often not feasible. This study takes a step forward, presenting a model-assisted POD (MAPOD) approach for the first time applied to distributed OFSs (DOFSs). The new MAPOD framework applied to DOFSs is validated through previous experimental results, considering the mode I delamination monitoring of a double-cantilever beam (DCB) specimen under quasi-static loading conditions. The results show how strain transfer, loading conditions, human factors, interrogator resolution, and noise can alter the damage detection capabilities of DOFSs. This MAPOD approach represents a tool to study the effects of varying environmental and operational conditions on SHM systems based on DOFSs and for the design optimization of the monitoring system.

2.
Sensors (Basel) ; 20(11)2020 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-32486244

RESUMO

Fiber optic sensors represent one of the most promising technologies for the monitoring of various engineering structures. A major challenge in the field is to analyze and predict the strain transfer to the fiber core reliably. Many authors developed analytical models of a coated optical fiber, assuming null strain at the ends of the bonding length. However, this configuration only partially reflects real experimental setups in which the cable structure can be more complex and the strains do not drastically reduce to zero. In this study, a novel strain transfer model for surface-bonded sensing cables with multilayered structure was developed. The analytical model was validated both experimentally and numerically, considering two surface-mounted cable prototypes with three different bonding lengths and five load cases. The results demonstrated the capability of the model to predict the strain profile and, differently from the available strain transfer models, that the strain values at the extremities of the bonded fiber length are not null.

3.
Opt Express ; 27(20): 29448-29459, 2019 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-31684679

RESUMO

In this work, we present an enhanced design for a Brillouin ring laser (BRL), which employs a double resonant cavity (DRC) with short fiber length, paired with a heterodyne-based wavelength-locking system, to be employed as a pump-probe source for Brillouin sensing. The enhanced source is compared to traditional long-cavity pump-probe source, showing a significantly lower relative intensity noise (~-145 dB/Hz in the whole 0-800 MHz range), a narrow linewidth (10 kHz), and large tunability features, resulting in an effective pump-probe source in BOTDA systems, with an excellent pump-probe frequency stability (~200 Hz), which is uncommon for fiber lasers. The enhanced source showed an improved signal-to-noise ratio (SNR) of about 22 dB with respect to standard BRL schemes, resulting in an improved temperature/strain resolution in BOTDA applications up to 5.5 dB, with respect to previous high-noise BRL designs.

4.
Sensors (Basel) ; 19(23)2019 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-31779144

RESUMO

Brillouin distributed optical fiber sensing (Brillouin D-FOS) is a powerful technology for real-time in situ monitoring of various physical quantities, such as strain, temperature, and pressure. Compared to local or multi-point fiber optic sensing techniques, in Brillouin-based sensing, the optical fiber is interrogated along its complete length with a resolution down to decimeters and with a frequency encoding of the measure information that is not affected by changes in the optical attenuation. The fiber sensing cable plays a significant role since it must ensure a low optical loss and optimal transfer of the measured parameters for a long time and in harsh conditions, e.g., the presence of moisture, corrosion, and relevant mechanical or thermal stresses. In this paper, research and application regarding optical fiber cables for Brillouin distributed sensing are reviewed, connected, and extended. It is shown how appropriate cable design can give a significant contribution toward the successful exploitation of the Brillouin D-FOS technique.

5.
Opt Express ; 23(5): 5930-40, 2015 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-25836819

RESUMO

In this paper we present a planar lightwave switching mechanism based on large refractive index variations induced by electrically-driven strain control in a CMOS-compatible photonic platform. Feasibility of the proposed concept, having general validity, is numerically analyzed in a specific case-study given by a Mach-Zehnder Interferometer with Ge waveguides topped by a piezoelectric stressor. The stressor can be operated in order to dynamically tune the strain into the two interferometric arms. The strain modifies the Ge band structure and can induce refractive index variations up to 0.05. We demonstrate that this approach can enable ultra-compact devices featuring low loss propagation for light wavelengths below the waveguide band gap energy, high extinction ratios (>30 dB) and low intrinsic insertion losses (2 dB). The operation wavelength can be extended in the whole FIR spectrum by using SiGe(Sn) alloy waveguides.

6.
Appl Opt ; 51(30): 7268-75, 2012 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-23089781

RESUMO

We propose and experimentally demonstrate the feasibility of an integrated hybrid optical fiber sensing interrogation technique that efficiently combines distributed Raman-based temperature sensing with fiber Bragg grating (FBG)-based dynamic strain measurements. The proposed sensing system is highly integrated, making use of a common optical source/receiver block and exploiting the advantages of both (distributed and point) sensing technologies simultaneously. A multimode fiber is used for distributed temperature sensing, and a pair of FBGs in each discrete sensing point, partially overlapped in the spectral domain, allows for temperature-independent discrete strain measurements. Experimental results report a dynamic strain resolution of 7.8 nε/√Hz within a full range of 1700 µÎµ and a distributed temperature resolution of 1°C at 20 km distance with 2.7 m spatial resolution.

7.
Opt Express ; 20(7): 6860-9, 2012 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-22453363

RESUMO

Sub-meter distributed optical fiber sensing based on Brillouin optical time-domain analysis with differential pulse-width pairs (DPP-BOTDA) is combined with the use of optical pre-amplification and pulse coding. In order to provide significant measurement SNR enhancement and to avoid distortions in the Brillouin gain spectrum due to acoustic-wave pre-excitation, the pulse width and duty cycle of Simplex coding based on return-to-zero pulses are optimized through simulations. In addition, the use of linear optical pre-amplification increases the receiver sensitivity and the overall dynamic range of DPP-BOTDA measurements. Experimental results demonstrate for first time a spatial resolution of ~25 cm over a 60 km standard single-mode fiber (equivalent to ~240 k discrete sensing points) with temperature resolution of 1.2°C and strain resolution of 24 µÎµ.


Assuntos
Amplificadores Eletrônicos , Fibras Ópticas , Refratometria/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Transdutores , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento
8.
Opt Lett ; 36(13): 2557-9, 2011 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-21725478

RESUMO

We experimentally investigate the benefits of a new optical pulse coding technique for long-range, meter and submeter scale Raman-based distributed temperature sensing on standard single-mode optical fibers. The proposed scheme combines a low-repetition-rate quasi-periodic pulse coding technique with the use of standard high-power fiber lasers operating at 1550 nm, allowing for what we believe is the first long-range distributed temperature measurement over single-mode fibers (SMFs). We have achieved 1 m spatial resolution over 26 km of SMF, attaining 3°C temperature resolution within 30 s measurement time.

9.
Opt Express ; 19(5): 4444-57, 2011 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-21369276

RESUMO

In this paper we perform an optimization of Brillouin optical time-domain analysis (BOTDA) sensors for achieving high resolution over long sensing ranges using distributed Raman amplification. By employing an optimized first-order bi-directional Raman amplification scheme and combining high-power fiber-Raman lasers and Fabry-Pérot lasers with low relative-intensity-noise (RIN), we demonstrate distributed sensing over 120 km of standard single-mode fiber with 2 meter spatial resolution and with a strain/temperature accuracy of 45µÎµ/2.1°C respectively.


Assuntos
Amplificadores Eletrônicos , Tecnologia de Fibra Óptica/instrumentação , Lasers , Refratometria/instrumentação , Análise Espectral Raman/instrumentação , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento
10.
Opt Lett ; 36(2): 232-4, 2011 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-21263510

RESUMO

In this Letter, we combine the use of optical preamplification at the receiver and optical pulse coding techniques with an optimized modulation format to effectively extend the sensing range of Brillouin optical time-domain analysis (BOTDA) sensors. Combining a return-to-zero modulation format with 25% duty cycle and linear gain preamplification allows for temperature and strain measurements over 120 km of standard single-mode fiber with 3 m spatial resolution and an rms strain-temperature accuracy of 3.1 °C/60 µÎµ respectively.

11.
Opt Express ; 18(14): 14878-92, 2010 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-20639975

RESUMO

A theoretical and experimental analysis of the impact of pulse modulation format on Brillouin optical time-domain analysis (BOTDA) sensors using pulse coding techniques has been carried out. Pulse coding with conventional non-return-to-zero (NRZ) modulation format is shown to induce significant distortions in the measured Brillouin gain spectrum (BGS), especially in proximity of abrupt changes in the fiber gain spectra. Such an effect, as confirmed by the theoretical analysis, is due to acoustic wave pre-excitation and non-uniform gain which depends on the bit patterns defined by the different codewords. A successful use of pulse coding techniques then requires to suitably optimize the employed modulation format in order to avoid spurious oscillations causing severe penalties in the attained accuracy. Coding technique with return-to-zero (RZ) modulation format is analyzed under different duty-cycle conditions for a 25 km-long sensing scheme, showing that low duty-cycle values are able to effectively suppress the induced distortions in the BGS and allow for spatially-accurate, high-resolution strain and temperature measurements being able to fully exploit the provided coding gain (approximately 7.2 dB along 25 km distance) with unaltered spatial resolution (1 meter). Although Simplex coding is used in our analysis, the validity of the results is general and can be directly applied to any intensity-modulation coding scheme.

12.
Opt Express ; 18(8): 8459-65, 2010 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-20588692

RESUMO

We demonstrate simultaneous strain and temperature sensing based on hybrid Raman and Brillouin scattering with enhanced performance thanks to the combined use of standard Fabry-Perot lasers in conjunction with optical pulse coding techniques. The combination of both techniques allows for an improvement of ~8.7 dB in temperature resolution and ~3 dB in strain resolution, with respect to standard distributed feedback lasers, as confirmed by experiments, resulting in a final temperature / strain resolution of ~0.27K / ~30microepsilon over 25-km sensing fiber range, avoiding the use of optical amplification and wavelength averaging techniques.

13.
Opt Lett ; 35(2): 259-61, 2010 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-20081987

RESUMO

In this Letter, we propose the use of optical pulse coding techniques for long-range distributed sensors based on Brillouin optical time-domain analysis (BOTDA). Compared to conventional BOTDA sensors, optical coding provides a significant sensing-range enhancement, allowing for temperature and strain measurements with 1 m spatial resolution over 50 km of standard single-mode fiber, with an accuracy of 2.2 degrees C/44 muepsilon, respectively.

14.
Opt Express ; 17(9): 6996-7003, 2009 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-19399073

RESUMO

We present a theoretical study of the performance of distributed Raman amplifiers with higher order pumping schemes, focusing in particular on double Rayleigh scattering (DRS) noise. Results show an unexpected significant DRS noise reduction for pumping order higher than third, allowing for an overall performance improvement of carefully designed distributed amplifiers, ensuring a large optical signal-to-noise ratio improvement together with reduced DRS-induced penalties.


Assuntos
Amplificadores Eletrônicos , Artefatos , Lasers de Estado Sólido , Modelos Teóricos , Análise Espectral Raman/instrumentação , Simulação por Computador , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Luz , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
15.
Opt Express ; 16(23): 19097-111, 2008 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-19582002

RESUMO

A theoretical and experimental analysis of optical pulse coding techniques applied to distributed optical fiber temperature sensors based on spontaneous Brillouin scattering using the Landau-Placzek ratio (LPR) scheme is presented, quantifying in particular the impact of Simplex coding on stimulated Brillouin and Raman power thresholds. The signal-to-noise ratio (SNR) enhancement and temperature resolution improvement provided by coding are also characterized. Experimental results confirm that, differently from Raman-based sensors, pulse coding affects the stimulated Brillouin threshold, resulting in lower optimal input power levels; these features allow one to achieve high sensing performance avoiding the use of high peak power pulses.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Refratometria/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Termografia/instrumentação , Termômetros , Transdutores , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Termografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...