Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
J Magn Reson Imaging ; 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39036994

RESUMO

BACKGROUND: Conventional liver magnetic resonance elastography (MRE) requires breath-holding (BH) to avoid motion artifacts, which is challenging for children. While radial free-breathing (FB)-MRE is an alternative for quantifying liver stiffness (LS), previous methods had limitations of long scan times, acquiring two slices in 5 minutes, and not resolving motion during reconstruction. PURPOSE: To reduce FB-MRE scan time to 4 minutes for four slices and to investigate the impact of self-gated (SG) motion compensation on FB-MRE LS quantification in terms of agreement, intrasession repeatability, and technical quality compared to conventional BH-MRE. STUDY TYPE: Prospective. POPULATION: Twenty-six children without fibrosis (median age: 12.9 years, 15 females). FIELD STRENGTH/SEQUENCE: 3 T; Cartesian gradient-echo (GRE) BH-MRE, research application radial GRE FB-MRE. ASSESSMENT: Participants were scanned twice to measure repeatability, without moving the table or changing the participants' position. LS was measured in areas of the liver with numerical confidence ≥90%. Technical quality was examined using measurable liver area (%). STATISTICAL TESTS: Agreement of LS between BH-MRE and FB-MRE was evaluated using Bland-Altman analysis for SG acceptance rates of 40%, 60%, 80%, and 100%. LS repeatability was assessed using within-subject coefficient of variation (wCV). The differences in LS and measurable liver area were examined using Kruskal-Wallis and Wilcoxon signed-rank tests. P < 0.05 was considered significant. RESULTS: FB-MRE with 60% SG achieved the closest agreement with BH-MRE (mean difference 0.00 kPa). The LS ranged from 1.70 to 1.83 kPa with no significant differences between BH-MRE and FB-MRE with varying SG rates (P = 0.52). All tested methods produced repeatable LS with wCV from 4.4% to 6.5%. The median measurable liver area was smaller for FB-MRE (32%-45%) than that for BH-MRE (91%-93%) (P < 0.05). DATA CONCLUSION: FB-MRE with 60% SG can quantify LS with close agreement and comparable repeatability with respect to BH-MRE in children. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 1.

2.
Magn Reson Med ; 91(5): 1923-1935, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38098427

RESUMO

PURPOSE: To demonstrate a novel MR elastography (MRE) technique, termed here wavelet MRE. With this technique, broadband motion sensitivity is achievable. Moreover, the true tissue displacement can be reconstructed with a simple inverse transform. METHODS: A wavelet MRE sequence was developed with motion-encoding gradients based on Haar wavelets. From the phase images' displacement was estimated using an inverse transform. Simulations were performed using a frequency sweep and a transient as ground-truth motions. A PVC phantom was scanned using wavelet MRE and standard MRE with both transient (one and 10 cycles of 90-Hz motion) and steady-state dual-frequency motion (30 and 60 Hz) for comparison. The technique was tested in a human brain, and motion trajectories were estimated for each voxel. RESULTS: In simulation, the displacement information estimated from wavelet MRE closely matched the true motion. In the phantom test, the MRE phase data generated from the displacement information derived from wavelet MRE agreed well with standard MRE data. Testing of wavelet MRE to assess transient motion waveforms in the brain was successful, and the tissue motion observed was consistent with a previous study. CONCLUSION: The uniform and broadband frequency response of wavelet MRE makes it a promising method for imaging transient, multifrequency motion, or motion with unknown frequency content. One potential application is measuring the response of brain tissue undergoing low-amplitude, transient vibrations as a model for the study of traumatic brain injury.


Assuntos
Técnicas de Imagem por Elasticidade , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Técnicas de Imagem por Elasticidade/métodos , Algoritmos , Encéfalo/diagnóstico por imagem , Imagens de Fantasmas , Som
3.
Eur Radiol ; 32(12): 8339-8349, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35727321

RESUMO

OBJECTIVES: Portal hypertension (PH) is associated with complications such as ascites and esophageal varices and is typically diagnosed through invasive hepatic venous pressure gradient (HVPG) measurement, which is not widely available. In this study, we aim to assess the diagnostic performance of 2D/3D MR elastography (MRE) and shear wave elastography (SWE) measures of liver and spleen stiffness (LS and SS) and spleen volume, to noninvasively diagnose clinically significant portal hypertension (CSPH) using HVPG measurement as the reference. METHODS: In this prospective study, patients with liver disease underwent 2D/3D MRE and SWE of the liver and spleen, as well as HVPG measurement. The correlation between MRE/SWE measures of LS/SS and spleen volume with HVPG was assessed. ROC analysis was used to determine the utility of MRE, SWE, and spleen volume for diagnosing CSPH. RESULTS: Thirty-six patients (M/F 22/14, mean age 55 ± 14 years) were included. Of the evaluated parameters, 3D MRE SS had the strongest correlation with HVPG (r = 0.686, p < 0.001), followed by 2D MRE SS (r = 0.476, p = 0.004). 3D MRE SS displayed the best performance for diagnosis of CSPH (AUC = 0.911) followed by 2D MRE SS (AUC = 0.845) and 3D MRE LS (AUC = 0.804). SWE SS showed poor performance for diagnosis of CSPH (AUC = 0.583) while spleen volume was a fair predictor (AUC = 0.738). 3D MRE SS was significantly superior to SWE LS/SS (p ≤ 0.021) for the diagnosis of CSPH. CONCLUSION: SS measured with 3D MRE outperforms SWE for the diagnosis of CSPH. SS appears to be a useful biomarker for assessing PH severity. These results need further validation. KEY POINTS: • Spleen stiffness measured with 2D and 3D MR elastography correlates significantly with hepatic venous pressure gradient measurement. • Spleen stiffness measured with 3D MR elastography demonstrates excellent performance for the diagnosis of clinically significant portal hypertension (AUC 0.911). • Spleen stiffness measured with 3D MR elastography outperforms liver and spleen stiffness measured with shear wave elastography for diagnosis of clinically significant portal hypertension.


Assuntos
Técnicas de Imagem por Elasticidade , Hipertensão Portal , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Técnicas de Imagem por Elasticidade/métodos , Estudos Prospectivos , Cirrose Hepática/complicações , Hipertensão Portal/complicações , Hipertensão Portal/diagnóstico por imagem , Hipertensão Portal/patologia , Pressão na Veia Porta , Fígado/patologia
4.
Pediatr Radiol ; 52(7): 1314-1325, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35366073

RESUMO

BACKGROUND: Magnetic resonance (MR) elastography of the liver measures hepatic stiffness, which correlates with the histopathological staging of liver fibrosis. Conventional Cartesian gradient-echo (GRE) MR elastography requires breath-holding, which is challenging for children. Non-Cartesian radial free-breathing MR elastography is a potential solution to this problem. OBJECTIVE: To investigate radial free-breathing MR elastography for measuring hepatic stiffness in children. MATERIALS AND METHODS: In this prospective pilot study, 14 healthy children and 9 children with liver disease were scanned at 3 T using 2-D Cartesian GRE breath-hold MR elastography (22 s/slice) and 2-D radial GRE free-breathing MR elastography (163 s/slice). Each sequence was acquired twice. Agreement in the stiffness measurements was evaluated using Lin's concordance correlation coefficient (CCC) and within-subject mean difference. The repeatability was assessed using the within-subject coefficient of variation and intraclass correlation coefficient (ICC). RESULTS: Fourteen healthy children and seven children with liver disease completed the study. Median (±interquartile range) normalized measurable liver areas were 62.6% (±26.4%) and 44.1% (±39.6%) for scan 1, and 60.3% (±21.8%) and 43.9% (±44.2%) for scan 2, for Cartesian and radial techniques, respectively. Hepatic stiffness from the Cartesian and radial techniques had close agreement with CCC of 0.89 and 0.94, and mean difference of 0.03 kPa and -0.01 kPa, for scans 1 and 2. Cartesian and radial techniques achieved similar repeatability with within-subject coefficient of variation=1.9% and 3.4%, and ICC=0.93 and 0.92, respectively. CONCLUSION: In this pilot study, radial free-breathing MR elastography was repeatable and in agreement with Cartesian breath-hold MR elastography in children.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatias , Criança , Técnicas de Imagem por Elasticidade/métodos , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Hepatopatias/patologia , Imageamento por Ressonância Magnética/métodos , Projetos Piloto , Estudos Prospectivos , Reprodutibilidade dos Testes
5.
Abdom Radiol (NY) ; 47(3): 998-1008, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34982182

RESUMO

PURPOSE: To evaluate performance of 3D magnetic resonance elastography (MRE) using spin-echo echo-planar imaging (seEPI) for assessment of hepatic stiffness compared with 2D gradient-recalled echo (GRE) and 2D seEPI sequences. METHODS: Fifty-seven liver MRE examinations including 2D GRE, 2D seEPI, and 3D seEPI sequences were retrospectively evaluated. Elastograms were analyzed by 2 radiologists and polygonal regions of interests (ROIs) were drawn in 2 different fashions: "curated" ROI (avoiding liver edge, major vessels, and areas of wave interferences) and "non-curated" ROI (including largest cross section of liver, to assess the contribution of artifacts). Liver stiffness measurement (LSM) was calculated as the arithmetic mean of individual stiffness values for each technique. For 3D MRE, LSMs were also calculated based on 4 slices ("abbreviated LSM"). Intra-patient variations in LSMs and different methods of ROI placement were assessed by univariate tests. A p-value of < 0.05 was set as a statistically significant difference. RESULTS: Mean surface areas of the ROIs were 50,723 mm2, 12,669 mm2, 5814 mm2, and 10,642 mm2 for 3D MRE, abbreviated 3D MRE, 2D GRE, and 2D seEPI, respectively. 3D LSMs based on curated and non-curated ROIs showed no clinically significant difference, with a mean difference less than 0.1 kPa. Abbreviated 3D LSMs had excellent correlation with 3D LSMs based on all slices (r = 0.9; p < 0.001) and were not significantly different (p = 0.927). CONCLUSION: 3D MRE allows more reproducible measurements due to its lower susceptibility to artifacts and provides larger areas of parenchyma, enabling a more comprehensive evaluation of the liver.


Assuntos
Técnicas de Imagem por Elasticidade , Imagem Ecoplanar/métodos , Técnicas de Imagem por Elasticidade/métodos , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/patologia , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos
6.
Phys Med Biol ; 66(5)2021 02 26.
Artigo em Inglês | MEDLINE | ID: mdl-33352538

RESUMO

A magnetic resonance (MR) shear wave elastography technique that uses transient acoustic radiation force impulses from a focused ultrasound (FUS) transducer and a sinusoidal-shaped MR displacement encoding strategy is presented. Using this encoding strategy, an analytic expression for calculating the shear wave speed in a heterogeneous medium was derived. Green's function-based simulations were used to evaluate the feasibility of calculating shear wave speed maps using the analytic expression. Accuracy of simulation technique was confirmed experimentally in a homogeneous gelatin phantom. The elastography measurement was compared to harmonic MR elastography in a homogeneous phantom experiment and the measured shear wave speed values differed by less than 14%. This new transient elastography approach was able to map the position and shape of inclusions sized from 8.5 to 14 mm in an inclusion phantom experiment. These preliminary results demonstrate the feasibility of using a straightforward analytic expression to generate shear wave speed maps from MR images where sinusoidal-shaped motion encoding gradients are used to encode the displacement-time history of a transiently propagating wave-packet. This new measurement technique may be particularly well suited for performing elastography before, during, and after MR-guided FUS therapies since the same device used for therapy is also used as an excitation source for elastography.


Assuntos
Simulação por Computador , Técnicas de Imagem por Elasticidade , Acústica , Técnicas de Imagem por Elasticidade/métodos , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas
7.
J Acoust Soc Am ; 145(2): 989, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30823819

RESUMO

A method is presented for tracking the internal deformation of self-oscillating vocal fold models using magnetic resonance imaging (MRI). Silicone models scaled to four times life-size to lower the flow-induced vibration frequency were embedded with fiducial markers in a coronal plane. Candidate marker materials were tested using static specimens, and two materials, cupric sulfate and glass, were chosen for testing in the vibrating vocal fold models. The vibrating models were imaged using a gated MRI protocol wherein MRI acquisition was triggered using the subglottal pressure signal. Two-dimensional image slices at different phases during self-oscillation were captured, and in each phase the fiducial markers were clearly visible. The process was also demonstrated using a three-dimensional scan at two phases. The benefit of averaging to increase signal-to-noise ratio was explored. The results demonstrate the ability to use MRI to acquire quantitative deformation data that could be used, for example, to validate computational models of flow-induced vocal fold vibration and quantify deformation fields encountered by cells in bioreactor studies.


Assuntos
Imageamento por Ressonância Magnética/métodos , Modelos Biológicos , Prega Vocal/diagnóstico por imagem , Desenho de Equipamento , Marcadores Fiduciais , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador , Silicones , Vibração
8.
Magn Reson Med ; 81(5): 3153-3167, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30663806

RESUMO

PURPOSE: To present a novel MR shear wave elastography (MR-SWE) method that efficiently measures the speed of propagating wave packets generated using acoustic radiation force (ARF) impulses. METHODS: ARF impulses from a focused ultrasound (FUS) transducer were applied sequentially to a preselected set of positions and motion encoded MRI was used to acquire volumetric images of the propagating shear wavefront emanating from each point. The wavefront position at multiple propagation times was encoded in the MR phase image using a train of motion encoding gradient lobes. Generating a transient propagating wavefront at multiple spatial positions and sampling each at multiple time-points allowed for shear wave speed maps to be efficiently created. MR-SWE was evaluated in tissue mimicking phantoms and ex vivo bovine liver tissue before and after ablation. RESULTS: MR-SWE maps, covering an in-plane area of ~5 × 5 cm, were acquired in 12 s for a single slice and 144 s for a volumetric scan. MR-SWE detected inclusions of differing stiffness in a phantom experiment. In bovine liver, mean shear wave speed significantly increased from 1.65 ± 0.18 m/s in normal to 2.52 ± 0.18 m/s in ablated region (n = 581 pixels; P-value < 0.001). CONCLUSION: MR-SWE is an elastography technique that enables precise targeting and excitation of the desired tissue of interest. MR-SWE may be particularly well suited for treatment planning and endpoint assessment of MR-guided FUS procedures because the same device used for therapy can be used as an excitation source for tissue stiffness quantification.


Assuntos
Acústica , Técnicas de Imagem por Elasticidade , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Animais , Bovinos , Modelos Animais , Movimento (Física) , Imagens de Fantasmas , Resistência ao Cisalhamento , Estresse Mecânico , Transdutores
9.
Abdom Radiol (NY) ; 44(3): 894-902, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30600386

RESUMO

PURPOSE: The goal of our study is to compare hepatic stiffness measures using gradient-recalled echo (GRE) versus spin-echo echo planar imaging (SE-EPI)-based MR Elastography (MRE) at 3T used to measure hepatic stiffness in a patients with suspected liver diseases. MATERIALS AND METHODS: This retrospective study included 52 patients with liver disease who underwent a 3T MRE exam including both an investigational SE-EPI-based technique and a product GRE-based technique. Regions of interest (ROI) were placed on the elastograms to measure elastography-derived liver stiffness as well as the area included within the ROIs. The mean liver stiffness values and area of ROIs were compared. RESULTS: The mean liver stiffness was 3.72 kilopascal (kPa) ± 1.29 using GRE MRE and 3.78 kPa ± 1.13 using SE-EPI MRE. Measurement of liver stiffness showed excellent agreement between the two pulse sequences with a mean bias of - 0.1 kPa (range - 1.8 to 1.7 kPa) between sequences. The mean measurable ROI area was higher with SE-EPI (313.8 cm2 ± 213.8) than with the GRE technique (208.6 cm2 ± 114.8), and the difference was statistically significant (P < 0.05). CONCLUSIONS: Our data shows excellent agreement of measured liver stiffness between GRE and SE-EPI-based sequences at 3T. Our results show the advantage of a SE-EPI MRE sequence in terms of image quality, ROI size and acquisition time with equivalent liver stiffness measurements as compared to GRE-MRE sequence.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Hepatopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Criança , Imagem Ecoplanar/métodos , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
10.
AJR Am J Roentgenol ; 211(3): 588-594, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29995500

RESUMO

OBJECTIVE: The objectives of our study were to compare MR elastography (MRE) based on gradient-recalled echo (GRE) imaging with spin-echo echo-planar imaging (SEEPI) and rapid fractional (RF)-GRE MRE sequences at 3 T in terms of liver stiffness (LS) and image quality and to evaluate the effect of liver R2* on image quality. MATERIALS AND METHODS: Eighty-one patients underwent 3-T liver MRE with GRE, SE-EPI, and RF-GRE sequences performed in variable order in this study. LS and ROI areas on the LS 95% confidence maps were compared among the three sequences. The relationship between liver R2* and ROI area was investigated. RESULTS: There was no significant difference in mean LS among the three sequences (p = 0.49). Mean ROI area was significantly larger for RF-GRE (18,213 ± 9292 [SD] mm2) than for GRE (13,196 ± 8149 mm2) and SE-EPI (12,896 ± 8656 mm2) (p < 0.0001). Liver R2* was significantly higher among patients with one or more failed sequences (mean ± SD, 116 ± 76 s-1) than for patients with no failed sequences (59 ± 26 s-1) (p = 0.001). Technical failure rates were 10% (8/81), 4% (3/81), and 2% (2/81) for GRE, SE-EPI, and RF-GRE, respectively. Among patients with iron overload (R2* ≥ 100 s-1), there was a trend toward larger ROI area for SE-EPI (p = 0.09). CONCLUSION: SE-EPI-and RF-GRE-based MRE sequences provide equivalent measures of LS compared with GRE-based MRE, and both have lower technical failure rates. The RF-GRE sequence yielded the largest measurable area of LS. Among patients with iron overload, there was a trend toward larger measurable area of LS for the SE-EPI sequence.


Assuntos
Imagem Ecoplanar , Técnicas de Imagem por Elasticidade , Cirrose Hepática/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
11.
Magn Reson Med ; 79(3): 1407-1419, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28643383

RESUMO

PURPOSE: Implement and evaluate a 3D MRI method to measure temperature changes with high spatial and temporal resolution and large field of view. METHODS: A multiecho pseudo-golden angle stack-of-stars (SOS) sequence with k-space weighted image contrast (KWIC) reconstruction was implemented to simultaneously measure multiple quantities, including temperature, initial signal magnitude M(0), transverse relaxation time ( T2*), and water/fat images. Respiration artifacts were corrected using self-navigation. KWIC artifacts were removed using a multi-baseline library. The phases of the multiple echo images were combined to improve proton resonance frequency precision. Temperature precision was tested through in vivo breast imaging (N = 5 healthy volunteers) using both coronal and sagittal orientations and with focused ultrasound (FUS) heating in a pork phantom using a breast specific MR-guided FUS system. RESULTS: Temperature measurement precision was significantly improved after echo combination when compared with the no echo combination case (spatial average of the standard deviation through time of 0.3-1.0 and 0.7-1.9°C, respectively). Temperature measurement accuracy during heating was comparable to a 3D seg-EPI sequence. M(0) and T2* values showed temperature dependence during heating in pork adipose tissue. CONCLUSION: A self-navigated 3D multiecho SOS sequence with dynamic KWIC reconstruction is a promising thermometry method that provides multiple temperature sensitive quantitative values. Magn Reson Med 79:1407-1419, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Termometria/métodos , Adulto , Algoritmos , Animais , Mama/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Imagens de Fantasmas , Suínos , Adulto Jovem
12.
Magn Reson Med ; 78(6): 2460-2468, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28185303

RESUMO

PURPOSE: To demonstrate the interchangeable neck shape-specific (NSS) coil concept that supplements standard commercial spine and head/neck coils to provide simultaneous high-resolution (hi-res) head/neck imaging with high signal-to-noise ratio (SNR). METHODS: Two NSS coils were constructed on formers designed to fit two different neck shapes. A 7-channel (7ch) ladder array was constructed on a medium neck former, and a 9-channel (9ch) ladder array was constructed on large neck former. Both coils were interchangeable with the same preamp housing. RESULTS: The 7ch and 9ch coils demonstrate SNR gains of approximately 4 times and 3 times over the Siemens 20-channel head/neck coil in the carotid arteries of our volunteers, respectively. Coupling between the Siemens 32-channel spine coil, Siemens 20-channel head/neck coil, and the NSS coils was negligible, allowing for simultaneous hi-res head/neck imaging with high SNR. CONCLUSIONS: This study demonstrates that supplementing existing commercial spine and head/neck coils with an NSS coil allows uniform simultaneous hi-res imaging with high SNR in the anterior neck, while maintaining SNR of the commercial coil in the head and posterior neck. Magn Reson Med 78:2460-2468, 2017. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Doenças das Artérias Carótidas/diagnóstico por imagem , Imageamento por Ressonância Magnética/instrumentação , Pescoço/diagnóstico por imagem , Razão Sinal-Ruído , Artérias Carótidas/diagnóstico por imagem , Queixo/diagnóstico por imagem , Simulação por Computador , Desenho de Equipamento , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Imagens de Fantasmas
13.
J Magn Reson Imaging ; 45(2): 410-417, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27383756

RESUMO

PURPOSE: Carotid artery imaging is important in the clinical management of patients at risk for stroke. Carotid intraplaque hemorrhage (IPH) presents an important diagnostic challenge. 3D magnetization prepared rapid acquisition gradient echo (MPRAGE) has been shown to accurately image carotid IPH; however, this sequence can be limited due to motion- and flow-related artifact. The purpose of this work was to develop and evaluate an improved 3D carotid MPRAGE sequence for IPH detection. We hypothesized that a radial-based k-space trajectory sequence such as "Stack of Stars" (SOS) incorporated with inversion recovery preparation would offer reduced motion sensitivity and more robust flow suppression by oversampling of central k-space. MATERIALS AND METHODS: A total of 31 patients with carotid disease (62 carotid arteries) were imaged at 3T magnetic resonance imaging (MRI) with 3D IR-prep Cartesian and SOS sequences. Image quality was determined between SOS and Cartesian MPRAGE in 62 carotid arteries using t-tests and multivariable linear regression. Kappa analysis was used to determine interrater reliability. RESULTS: In all, 25 among 62 carotid plaques had carotid IPH by consensus from the reviewers on SOS compared to 24 on Cartesian sequence. Image quality was significantly higher with SOS compared to Cartesian (mean 3.74 vs. 3.11, P < 0.001). SOS acquisition yielded sharper image features with less motion (19.4% vs. 45.2%, P < 0.002) and flow artifact (27.4% vs. 41.9%, P < 0.089). There was also excellent interrater reliability with SOS (kappa = 0.89), higher than that of Cartesian (kappa = 0.84). CONCLUSION: By minimizing flow and motion artifacts and retaining high interrater reliability, the SOS MPRAGE has important advantages over Cartesian MPRAGE in carotid IPH detection. LEVEL OF EVIDENCE: 1 J. Magn. Reson. Imaging 2017;45:410-417.


Assuntos
Doenças das Artérias Carótidas/diagnóstico por imagem , Hemorragia/diagnóstico por imagem , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Idoso , Artefatos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Magn Reson Imaging ; 37: 51-55, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27864008

RESUMO

PURPOSE: To propose and validate a method for accurately quantifying renal plasma flow (RPF) with arterial spin labeling (ASL). MATERIALS AND METHODS: The proposed method employs a tracer-kinetic approach and derives perfusion from the slope of the ASL difference signal sampled at multiple inversion-times (TIs). To validate the method's accuracy, we performed a HIPAA-compliant and IRB-approved study with 15 subjects (9 male, 6 female; age range 24-73) to compare RPF estimates obtained from ASL to those from a more established dynamic contrast-enhanced (DCE) MRI method. We also investigated the impact of TI-sampling density on the accuracy of estimated RPF. RESULTS: Good agreement was found between ASL- and DCE-measured RPF, with a mean difference of 9±30ml/min and a correlation coefficient R=0.92 when ASL signals were acquired at 16 TIs and a mean difference of 9±57ml/min and R=0.81 when ASL signals were acquired at 5 TIs. RPF estimated from ASL signals acquired at only 2 TIs (400 and 1200ms) showed a low correlation with DCE-measured values (R=0.30). CONCLUSION: The proposed ASL method is capable of measuring RPF with an accuracy that is comparable to DCE MRI. At least 5 TIs are recommended for the ASL acquisition to ensure reliability of RPF measurements.


Assuntos
Meios de Contraste , Imageamento por Ressonância Magnética , Fluxo Plasmático Renal , Marcadores de Spin , Adulto , Idoso , Artérias , Feminino , Gadolínio/farmacologia , Humanos , Processamento de Imagem Assistida por Computador , Cinética , Masculino , Pessoa de Meia-Idade , Perfusão , Reprodutibilidade dos Testes
15.
Magn Reson Med ; 77(6): 2424-2430, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-27418429

RESUMO

PURPOSE: To develop a method for rapid prediction of the geometric focus location in MR coordinates of a focused ultrasound (US) transducer with arbitrary position and orientation without sonicating. METHODS: Three small tracker coil circuits were designed, constructed, attached to the transducer housing of a breast-specific MR-guided focused US (MRgFUS) system with 5 degrees of freedom, and connected to receiver channel inputs of an MRI scanner. A one-dimensional sequence applied in three orthogonal directions determined the position of each tracker, which was then corrected for gradient nonlinearity. In a calibration step, low-level heating located the US focus in one transducer position orientation where the tracker positions were also known. Subsequent US focus locations were determined from the isometric transformation of the trackers. The accuracy of this method was verified by comparing the tracking coil predictions to thermal center of mass calculated using MR thermometry data acquired at 16 different transducer positions for MRgFUS sonications in a homogeneous gelatin phantom. RESULTS: The tracker coil predicted focus was an average distance of 2.1 ± 1.1 mm from the thermal center of mass. The one-dimensional locator sequence and prediction calculations took less than 1 s to perform. CONCLUSION: This technique accurately predicts the geometric focus for a transducer with arbitrary position and orientation without sonicating. Magn Reson Med 77:2424-2430, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Interpretação de Imagem Assistida por Computador/instrumentação , Imagem por Ressonância Magnética Intervencionista/instrumentação , Magnetismo/instrumentação , Transdutores , Terapia por Ultrassom/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Interpretação de Imagem Assistida por Computador/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Terapia por Ultrassom/métodos
16.
Ann Am Thorac Soc ; 13(1): 49-57, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26633593

RESUMO

RATIONALE: Computed tomographic (CT) radiography is the reference standard for imaging Mycobacterium avium complex (MAC) lung infection. Magnetic resonance imaging (MRI) has been shown to be comparable to CT for characterizing other pulmonary inflammatory conditions, but has not been rigorously tested for imaging MAC pneumonia. OBJECTIVES: To determine the feasibility of pulmonary MRI for imaging MAC pneumonia and to assess the degree of agreement between MRI and CT for assessing the anatomic features and lobar extent of MAC lung infections. METHODS: Twenty-five subjects with culture-confirmed MAC pneumonia and no identified coinfecting organisms were evaluated by thoracic MRI and then by chest CT imaging performed up to 1 week later. After deidentification, first the MRI and then the CT scans were scored 2 weeks apart by two chest radiologists working independently of one another. Discrepancies were resolved by a third chest radiologist. The scans were scored for bronchiectasis, consolidation or atelectasis, abscess or sacculation, nodules, and mucus plugging using a three-point lobar scale (absent, <50% of lobe, and >50% of lobe). Agreement analyses and ordinary least products regressions were performed. MEASUREMENTS AND MAIN RESULTS: A fixed bias was found between total CT and MRI scores, with CT scoring higher on average (median difference: 4 on a scale of 48; interquartile range: 3, 6). Fixed biases were found for bronchiectasis and consolidation or atelectasis subscale scores. Both fixed and proportional biases were found between CT and MRI mucus plugging scores. No bias was found between CT and MRI nodule scores. There was nearly perfect lobar percent agreement for more conspicuous findings such as consolidation or atelectasis and abscess or sacculation. CONCLUSIONS: In this exploratory study of 25 adult patients with culture-proven MAC lung infection, we found moderate agreement between MRI and CT for assessing the anatomic features and lobar extent of disease. Given the feasibility of chest MRI for this condition, future work is warranted to assess the clinical impact of MRI compared with CT in assessing progression of untreated MAC infection and response to treatment over time.


Assuntos
Imageamento por Ressonância Magnética/métodos , Infecção por Mycobacterium avium-intracellulare , Pneumonia Bacteriana , Tomografia Computadorizada por Raios X/métodos , Idoso , Pesquisa Comparativa da Efetividade , Estudos de Viabilidade , Feminino , Humanos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Masculino , Pessoa de Meia-Idade , Complexo Mycobacterium avium/isolamento & purificação , Infecção por Mycobacterium avium-intracellulare/diagnóstico , Infecção por Mycobacterium avium-intracellulare/fisiopatologia , Pneumonia Bacteriana/diagnóstico , Pneumonia Bacteriana/microbiologia , Reprodutibilidade dos Testes
17.
Acta Radiol ; 57(9): 1099-106, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25711231

RESUMO

BACKGROUND: Magnetic resonance elastography (MRE) at 3 T MR has the potential to improve the objective detection of skeletal muscle stiffness. PURPOSE: To determine the feasibility of MRE using 3 T MR for measurement of the stiffness of shoulder muscles in subjects. MATERIAL AND METHODS: This study prospectively evaluated 16 healthy subjects (mean age, 29.8 years; range, 25-51 years). MRE was acquired with 3 T MR through the use of a 2D-gradient-echo-based MRE sequence at two different excitation frequencies (90 and 120 Hz). The mean stiffness values (MSV) of the trapezius and infraspinatus muscles were measured by two radiologists. Differences between the MSV in the x, y, and z motion-sensitization directions were assessed. Inter-observer agreement was also measured. RESULTS: The MSV of the trapezius muscle were 2.72 kPa ± 0.6 (SD) at 90 Hz and 4.66 kPa ± 1.2 at 120 Hz, while the MSV for the infraspinatus muscle were 3.2 kPa ± 0.52 at 90 Hz and 4.38 kPa ± 0.92 at 120 Hz. The MSV for both muscles were significantly higher at 120 Hz than at 90 Hz (P < 0.05). The MSV in the three different directions were significantly different from each other in the infraspinatus muscle (P < 0.05). Levels of inter-observer agreement regarding MSV were good to excellent for both the trapezius (intraclass correlation coefficient [ICC] = 0.979-0.996) and infraspinatus muscles (ICC = 0.614-0.943). CONCLUSION: MRE at 3 T is a feasible technique for the evaluation of shoulder muscle stiffness. Extended application of skeletal muscle MRE at 3 T will contribute to the evaluation and treatment of skeletal muscle disorders.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiopatologia , Ombro/diagnóstico por imagem , Ombro/fisiopatologia , Adulto , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
18.
J Comput Assist Tomogr ; 39(3): 317-20, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25783798

RESUMO

BACKGROUND AND PURPOSE: The purpose of this study was to determine if magnetic resonance (MR) susceptibility-weighted imaging (SWI) can increase the conspicuity of corticomedullary veins within the white matter lesions of multiple sclerosis (MS) and, thus, aid in distinguishing plaques from leukoaraiosis. METHODS: We retrospectively reviewed MR examinations in 21 patients with a clinical diagnosis of MS and 18 patients with a clinical diagnosis of dementia. Examinations included fluid-attenuated inversion recovery (FLAIR) and SWI sequences obtained in the axial plane. Lesions greater than 5 mm in diameter on the axial FLAIR sequence were identified as periventricular or subcortical. Three neuroradiologists evaluated SWI images, compared with FLAIR, for a centrally located signal void in each lesion that was scored as present, absent, or indeterminate. RESULTS: In patients with MS, central veins were present in both periventricular lesions (75%, P < 0.001) and subcortical lesions (52%, P < 0.005). In patients with dementia, central veins were seen much less frequently in subcortical lesions (14%, P < 0.001); their association with periventricular lesions was not significant. CONCLUSIONS: Central veins were detected in MS lesions with a significantly greater frequency than that in patients with dementia. Susceptibility-weighted imaging increases the conspicuity of corticomedullary veins and may improve the specificity of MR findings in MS.


Assuntos
Veias Cerebrais/patologia , Transtornos Cerebrovasculares/patologia , Demência/patologia , Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla/patologia , Placa Aterosclerótica/patologia , Substância Branca/patologia , Idoso , Diagnóstico Diferencial , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
19.
Magn Reson Imaging ; 32(6): 679-83, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24637083

RESUMO

Magnetic resonance elastography (MRE) of the liver is a novel noninvasive clinical diagnostic tool to stage fibrosis based on measured stiffness. The purpose of this study is to design, evaluate and validate a rapid MRE acquisition technique for noninvasively quantitating liver stiffness which reduces by half the scan time, thereby decreasing image registration errors between four MRE phase offsets. In vivo liver MRE was performed on 16 healthy volunteers and 14 patients with biopsy-proven liver fibrosis using the standard clinical gradient recalled echo (GRE) MRE sequence (MREs) and a developed rapid GRE MRE sequence (MREr) to obtain the mean stiffness in an axial slice. The mean stiffness values obtained from the entire group using MREs and MREr were 2.72±0.85 kPa and 2.7±0.85 kPa, respectively, representing an insignificant difference. A linear correlation of R(2)=0.99 was determined between stiffness values obtained using MREs and MREr. Therefore, we can conclude that MREr can replace MREs, which reduces the scan time to half of that of the current standard acquisition (MREs), which will facilitate MRE imaging in patients with inability to hold their breath for long periods.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Cirrose Hepática/diagnóstico , Cirrose Hepática/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Adulto , Biópsia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
20.
J Comput Assist Tomogr ; 38(2): 216-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24625597

RESUMO

Four-dimensional flow is a magnetic resonance technology that has undergone significant technical improvements in recent years. With increasingly rapid acquisition times and new postprocessing tools, it can provide a tool for demonstrating and visualizing cardiovascular flow phenomena, which may offer new insights into disease. We present an interesting clinical case in which 4-dimensional flow demonstrates potential etiologies for 2 interesting phenomena in the same patient: (1) development of an unusual aneurysm and (2) cryptogenic stroke.


Assuntos
Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/fisiopatologia , Hemodinâmica/fisiologia , Angiografia por Ressonância Magnética/métodos , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/fisiopatologia , Aneurisma da Aorta Torácica/complicações , Velocidade do Fluxo Sanguíneo , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Acidente Vascular Cerebral/etiologia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...