Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Vet Ophthalmol ; 23(3): 534-543, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32162773

RESUMO

OBJECTIVE: To characterize diagnostic findings, test-retest repeatability, and correlations among lacrimal tests in dogs of diverse cephalic conformations. ANIMAL STUDIED: Fifty healthy dogs (25 brachycephalic, 25 nonbrachycephalic). PROCEDURES: A series of diagnostics were performed in each dog, allowing for a 10-minute interval between tests and repeating each test 24 hours later under similar conditions: corneal tactile sensation (CTS), strip meniscometry test (SMT), phenol red thread test (PRTT), endodontic absorbent paper point tear test (EAPPTT), Schirmer tear test-1 without (STT-1) or with nasolacrimal stimulation (NL-STT1), and Schirmer tear test-2 (STT-2). RESULTS: Mean ± SD test values were lower in brachycephalic vs. nonbrachycephalic dogs (except for SMT; 7.4 ± 2.0 mm/5 seconds vs 7.3 ± 2.4 mm/5 seconds), with statistically significant differences noted for CTS (1.8 ± 0.5 cm vs 3.4 ± 0.8 cm), PRTT (37.2 ± 4.0 mm/15 seconds vs 41.1 ± 5.5 mm/15 seconds), STT-1 (20.1 ± 3.4 mm/min vs 23.3 ± 5.7 mm/min), STT-2 (13.0 ± 3.4 mm/min vs 16.9 ± 3.9 mm/min), and NL-STT1 (23.2 ± 3.6 mm/min vs 27.1 ± 5.4 mm/min), and nonsignificant differences for EAPPTT (16.6 ± 2.7 mm/15 seconds vs 17.5 ± 2.9 mm/15 seconds). Nasolacrimal stimulation increased STT-1 values by 18% on average. Correlations among tests were generally weak to moderate (r < .70) except for a strong correlation between STT-1 and NL-STT1 (r = .83, P < .001). Test reliability was good although test-retest repeatability was generally poor to moderate, as depicted by low intraclass correlation coefficients (ICC ≤ 0.75) and wide 95% limits of agreement, except for CTS (ICC = 0.91). CONCLUSIONS: Corneal sensitivity and aqueous tear secretion are lower in brachycephalic dogs. A comprehensive assessment of the ocular surface requires the combination of several diagnostic tests. The nasolacrimal reflex may provide a useful diagnostic and therapeutic tool in dogs.


Assuntos
Ducto Nasolacrimal/fisiologia , Lágrimas/fisiologia , Animais , Técnicas de Diagnóstico Oftalmológico/veterinária , Cães , Feminino , Masculino , Linhagem , Fitas Reagentes , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...