Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cancers (Basel) ; 15(13)2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37444549

RESUMO

BACKGROUND: Indeterminate adrenal masses (AM) pose a diagnostic challenge, and 2-[18F]FDG PET-CT serves as a problem-solving tool. Aim of this study was to investigate whether CT radiomics features could be used to predict the 2-[18F]FDG SUVmax of AM. METHODS: Patients with AM on 2-[18F]FDG PET-CT scan were grouped based on iodine contrast injection as CT contrast-enhanced (CE) or CT unenhanced (NCE). Two-dimensional segmentations of AM were manually obtained by multiple operators on CT images. Image resampling and discretization (bin number = 16) were performed. 919 features were calculated using PyRadiomics. After scaling, unstable, redundant, and low variance features were discarded. Using linear regression and the Uniform Manifold Approximation and Projection technique, a CT radiomics synthetic value (RadSV) was obtained. The correlation between CT RadSV and 2-[18F]FDG SUVmax was assessed with Pearson test. RESULTS: A total of 725 patients underwent PET-CT from April 2020 to April 2021. In 150 (21%) patients, a total of 179 AM (29 bilateral) were detected. Group CE consisted of 84 patients with 108 AM (size = 18.1 ± 4.9 mm) and Group NCE of 66 patients with 71 AM (size = 18.5 ± 3.8 mm). In both groups, 39 features were selected. No statisticallyf significant correlation between CT RadSV and 2-[18F]FDG SUVmax was found (Group CE, r = 0.18 and p = 0.058; Group NCE, r = 0.13 and p = 0.27). CONCLUSIONS: It might not be feasible to predict 2-[18F]FDG SUVmax of AM using CT RadSV. Its role as a problem-solving tool for indeterminate AM remains fundamental.

2.
Heliyon ; 8(1): e08819, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35097234

RESUMO

PURPOSE: To compare the impact of COVID-19 pandemic on 2-[18F]FDG PET/CT imaging work-flow during the three waves in a medical institution of southern of Italy. METHODS: We retrospectively reviewed the numbers and results of 2-[18F]FDG PET/CT studies acquired during the following three periods of the COVID-19 waves: 1) February 3-April 30, 2020; 2) October 15, 2020-January 15, 2021; and 3) January 18-April 16, 2021. RESULTS: A total of 861 PET/CT studies in 725 patients (388 men, mean age 64 ± 4 years) was acquired during the three waves of COVID-19 pandemic. The majority (94%) was performed for diagnosis/staging (n = 300) or follow-up (n = 512) of neoplastic diseases. The remaining 49 studies (6%) were acquired for non-oncological patients. The distribution of number and type of clinical indications for PET/CT studies in the three waves were comparable (p = 0.06). Conversely, the occurrence of patients positive for COVID-19 infection progressively increased (p < 0.0001) from the first to third wave; in particular, patients with COVID-19 had active infection before PET/CT study as confirmed by molecular oro/nasopharyngeal swab. CONCLUSION: Despite the restrictive medical measures for the emergency, the number of 2-[18F]FDG PET/CT studies was unchanged during the three waves guaranteeing the diagnostic performance of PET/CT imaging for oncological patients.

3.
Eur J Nucl Med Mol Imaging ; 47(11): 2691-2697, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32572561

RESUMO

PURPOSE: To assess the impact of the Covid-19 pandemic on FDG-PET/CT work volume and to evaluate the occurrence of abnormal imaging findings suspicious or potentially diagnostic for interstitial pneumonia by Covid-19 infection in south Italy. METHODS: We retrospectively reviewed the number and the findings of FDG-PET/CT studies acquired between February and April 2020 during the Covid-19 pandemic at the University of Napoli Federico II. The number and the findings of FDG-PET/CT studies acquired in the corresponding period of 2019 were also assessed for direct comparison. RESULTS: The number of FDG-PET/CT studies performed during the pandemic (n = 299) and in the corresponding period of 2019 (n = 335) were comparable. The percentage of abnormal FDG-PET/CT findings, suspicious for interstitial pneumonia by Covid-19 infection, was significantly higher during the pandemic (9%) compared with that found in the corresponding period of 2019 (4%) (χ2 5.45, P = 0.02). No significant differences were observed in the distribution of Covid-19 reporting and data system (CO-RADS) classification and in the maximum standardized uptake value between the pandemic (2.6 ± 2.2) and the corresponding period of 2019 (3.2 ± 1.4). Of note, patients with abnormal imaging findings during the pandemic time had clinical data and/or laboratory tests negative for Covid-19 infection. CONCLUSION: Despite the restrictive medical measures for the emergency, the number of FDG-PET/CT studies was unchanged during the pandemic compared with the previous year. Our findings also indicate that Covid-19 infection was contained in our series of patients from southern Italy.


Assuntos
Betacoronavirus , Infecções por Coronavirus/diagnóstico por imagem , Pandemias , Pneumonia Viral/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , COVID-19 , Carcinoma/complicações , Carcinoma/diagnóstico por imagem , Infecções por Coronavirus/complicações , Radioisótopos de Flúor , Fluordesoxiglucose F18 , Humanos , Itália/epidemiologia , Neoplasias Laríngeas/complicações , Neoplasias Laríngeas/diagnóstico por imagem , Pneumonia Viral/complicações , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/estatística & dados numéricos , Utilização de Procedimentos e Técnicas , Compostos Radiofarmacêuticos , Estudos Retrospectivos , SARS-CoV-2 , Timoma/complicações , Timoma/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...