Med Phys ; 27(10): 2198-208, 2000 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11099186

RESUMO

A two-dimensionally position sensitive dosimetry system has been tested for different dosimetric applications in a radiation therapy facility with a scanning proton beam. The system consists of a scintillating (fluorescent) screen, mounted at the beam-exit side of a phantom and it is observed by a charge coupled device (CCD) camera. The observed light distribution at the screen is equivalent to the two-dimensional (2D)-dose distribution at the screen position. It has been found that the dosimetric properties of the system, measured in a scanning proton beam, are equal to those measured in a proton beam broadened by a scattering system. Measurements of the transversal dose distribution of a single pencil beam are consistent with dose measurements as well as with dose calculations in clinically relevant fields made with multiple pencil beams. Measurements of inhomogeneous dose distributions have shown to be of sufficient accuracy to be suitable for the verification of dose calculation algorithms. The good sensitivity and sub-mm spatial resolution of the system allows for the detection of deviations of a few percent in dose from the expected (intended or calculated) dose distribution. Its dosimetric properties and the immediate availability of the data make this device a useful tool in the quality control of scanning proton beams.


Assuntos
Planejamento da Radioterapia Assistida por Computador/instrumentação , Algoritmos , Fluorescência , Humanos , Imagens de Fantasmas , Prótons , Controle de Qualidade , Planejamento da Radioterapia Assistida por Computador/normas , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Radioterapia de Alta Energia , Ecrans Intensificadores para Raios X
2.
Med Phys ; 25(4): 464-75, 1998 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9571612

RESUMO

A quality control system especially designed for dosimetry in scanning proton beams has been designed and tested. The system consists of a scintillating screen (Gd2O2S:Tb), mounted at the beam-exit side of a phantom, and observed by a low noise CCD camera with a long integration time. The purpose of the instrument is to make a fast and accurate two-dimensional image of the dose distribution at the screen position in the phantom. The linearity of the signal with the dose, the noise in the signal, the influence of the ionization density on the signal, and the influence of the field size on the signal have been investigated. The spatial resolution is 1.3 mm (1 s.d.), which is sufficiently smaller than typical penumbras in dose distributions. The measured yield depends linearly on the dose and agrees within 5% with the calculations. In the images a signal to noise ration (signal/1 s.d.) of 10(2) has been found, which is in the same order of magnitude as expected from the calculations. At locations in the dose distribution possessing a strong contribution of high ionization densities (i.e., in the Bragg peak), we found some quenching of the light output, which can be described well by existing models if the beam characteristics are known. For clinically used beam characteristics such as a Spread Out Bragg peak, there is at most 8% deviation from the NACP ionization chamber measurements. The conclusion is that this instrument is a useful tool for quick and reliable quality control of proton beams. The long integration-time capabilities of the system make it worthwhile to investigate its applicability in scanning proton beams and other dynamic treatment modalities.


Assuntos
Modelos Teóricos , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Braquiterapia , Desenho de Equipamento , Humanos , Polimetil Metacrilato , Prótons , Controle de Qualidade , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/instrumentação , Planejamento da Radioterapia Assistida por Computador/normas , Contagem de Cintilação , Raios X