Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
3.
Front Pediatr ; 11: 1215928, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37465418

RESUMO

Constrictive pericarditis is a chronic inflammatory process that can lead to heart failure if not diagnosed and treated correctly. Although Epstein-Barr virus (EBV)-related pericarditis is a very rare condition, it should still be considered for a differential diagnosis. We report the case of an 18-year-old male, who was surgically treated for constrictive pericarditis, in which in situ hybridization to Epstein-Barr virus-encoded RNA (EBER) probe of the excised pericardium led to the subsequent etiological diagnosis of chronic pericarditis caused by EBV.

4.
Front Pediatr ; 10: 876742, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35652057

RESUMO

The Fontan operation represents the final stage of a series of palliative surgical procedures for children born with complex congenital heart disease, where a "usual" biventricular physiology cannot be restored. The palliation results in the direct connection of the systemic venous returns to the pulmonary arterial circulation without an interposed ventricle. In this unique physiology, systemic venous hypertension and intrathoracic pressures changes due to respiratory mechanics play the main role for propelling blood through the pulmonary vasculature. Although the Fontan operation has dramatically improved survival in patients with a single ventricle congenital heart disease, significant morbidity is still a concern. Patients with Fontan physiology are in fact suffering from a multitude of complications mainly due to the increased systemic venous pressure. Consequently, these patients need close clinical and imaging monitoring, where cardiac exams play a key role. In this article, we review the main cardiac imaging modalities available, summarizing their main strengths and limitations in this peculiar setting. The main purpose is to provide a practical approach for all clinicians involved in the care of these patients, even for those less experienced in cardiac imaging.

5.
Radiol Cardiothorac Imaging ; 4(2): e210109, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35506130

RESUMO

Purpose: To compare real-time compressed sensing (CS) and standard balanced steady-state free precession (bSSFP) cardiac cine imaging in children. Materials and Methods: Twenty children (mean age, 15 years ± 5 [SD], range, 7-21 years; 10 male participants) with biventricular congenital heart disease (n = 11) or cardiomyopathy (n = 9) were prospectively included. Examinations were performed with 1.5-T imagers by using both bSSFP and CS sequences in all participants. Quantification of ventricular volumes and function was performed for all images by two readers blinded to patient diagnosis and type of sequence. Values were correlated with phase-contrast flow measurements by one reader. Intra- and interreader agreement were analyzed. Results: There were no significant differences between ventricular parameters measured on CS compared with those of bSSFP (P > .05) for reader 1. Only ejection fraction showed a significant difference (P = .02) for reader 2. Intrareader agreement was considerable for both sequences (bSSFP: mean difference range, +1 to -2.6; maximum CI, +7.9, -13; bias range, 0.1%-4.1%; intraclass correlation coefficient [ICC] range, 0.931-0.997. CS: mean difference range, +7.4 to -5.6; maximum CI, +37.2, -48.8; bias range, 0.5%-7.5%; ICC range, 0.717-0.997). Interreader agreement was acceptable but less robust, especially for CS (bSSFP: mean difference range, +2.6 to -5.6; maximum CI, +60.7, -65.3; bias range, 1.6%-6.2%; ICC range, 0.726-0.951. CS: mean difference range, +10.7 to -9.1; maximum CI, +87.5, -84.6; bias range, 1.1%-17.3%; ICC range, 0.509-0.849). The mean acquisition time was shorter for CS (20 seconds; range, 17-25 seconds) compared with that for bSSFP (160 seconds; range, 130-190 seconds) (P < .001). Conclusion: CS cardiac cine imaging provided equivalent ventricular volume and function measurements with shorter acquisition times compared with those of bSSFP and may prove suitable for the pediatric population.Keywords: Compressed Sensing, Balanced Steady-State Free Precession, Cine Imaging, Cardiovascular MRI, Pediatrics, Cardiac, Heart, Cardiomyopathies, Congenital, Segmentation© RSNA, 2022.

6.
Am J Med Genet A ; 188(8): 2351-2359, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35491976

RESUMO

Crossed pulmonary arteries (CPAs) represent an uncommon anatomic variant, usually associated with some specific syndromes and conotruncal defects. This finding has been described in 22q11.2 Deletion Syndrome (22q11.2DS). We evaluated the correlation between CPAs and genetic diseases, in order to better define the characteristics of this variant, considered a rare anatomic pattern. An in-depth analysis of CPAs genotype-phenotype correlations was performed via a literature review. We detected 74 CPAs patients through echocardiography. Of these 74 patients, 35.1% of patients showed additional intracardiac malformations, while 29.7% showed extracardiac vascular anomalies, of which 16.2% were associated with intracardiac defects and 13.5% were not. In all, 62.2% of patients were diagnosed with genetic diseases and 52.2% of them were 22q11.2DS patients. In conclusions, CPAs represent a cardiovascular variant, which is detectable in nonsyndromic individuals, but especially in various genetic syndromes and in particular in 22q11.2DS patients. Data on the real prevalence of this morphology is lacking in literature. Knowledge of this anatomic variant is useful to interpret the unusual course of the pulmonary branches and is helpful information before cardiovascular surgical correction. Moreover, due to the strong association of CPAs with some genetic syndromes, the identification of this anatomic pattern can indicate the utility of a genetic assessment of these patients.


Assuntos
Síndrome de DiGeorge , Cardiopatias Congênitas , Deleção Cromossômica , Cromossomos Humanos Par 22 , Síndrome de DiGeorge/diagnóstico , Síndrome de DiGeorge/genética , Cardiopatias Congênitas/diagnóstico , Humanos , Pulmão , Artéria Pulmonar/diagnóstico por imagem
7.
Artigo em Inglês | MEDLINE | ID: mdl-35329123

RESUMO

OBJECTIVE: Our goal is to evaluate the effects of heat and ultraviolet (UV) irradiation on P3 facial respirator microstructure. INTERVENTION: P3 facial filters were exposed to dry heat and UV sterilization procedures. METHODS: P3 facial filter samples underwent a standardized sterilization process based on dry heat and UV irradiation techniques. We analyzed critical parameters of internal microstructure, such as fiber thickness and porosity, before and after sterilization, using 3D data obtained with synchrotron radiation-based X-ray computed microtomography (micro-CT). The analyzed filter has two inner layers called the "finer" and "coarser" layers. The "finer" layer consists of a dense fiber network, while the "coarser" layer has a less compact fiber network. RESULTS: Analysis of 3D images showed no statistically significant differences between the P3 filter of the controls and the dry heat/UV sterilized samples. In particular, averages fiber thickness in the finer layer of the control and the 60° dry heated and UV-irradiated sample groups was almost identical. Average fiber thickness for the coarser layer of the control and the 60° dry heated and UV-irradiated sample groups was very similar, measuring 19.33 µm (±0.47), 18.33 µm (±0.47), and 18.66 µm (±0.47), respectively. There was no substantial difference in maximum fiber thickness in the finer layers and coarser layers. For the control group samples, maximum thickness was on average 11.43 µm (±1.24) in the finer layer and 59.33 µm (±6.79) in the coarser layer. Similarly, the 60° dry heated group samples were thickened 12.2 µm (±0.21) in the finer layer and 57.33 µm (±1.24) in the coarser layer, while for the UV-irradiated group, the mean max thickness was 12.23 µm (±0.90) in the finer layer and 58.00 µm (±6.68) in the coarser layer. Theoretical porosity analysis resulted in 74% and 88% for the finer and coarser layers. The finer layers' theoretical porosity tended to decrease in dry heat and UV-irradiated samples compared with the respective control samples. CONCLUSIONS: Dry heat and UV sterilization processes do not substantially alter the morphometry of the P3 filter samples' internal microstructure, as studied with micro-CT. The current study suggests that safe P3 filter facepiece reusability is theoretically feasible and should be further investigated.


Assuntos
Temperatura Alta , Pandemias , Esterilização , Raios Ultravioleta , Microtomografia por Raio-X
8.
J Magn Reson Imaging ; 55(5): 1452-1458, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34374157

RESUMO

BACKGROUND: Left-to-right (L-R) shunts are characterized by a pathological connection between high- and low-pressure systems, leading to a mixing of oxygen-rich blood with low oxygenated blood. They are typically diagnosed by phase-contrast cardiac magnetic resonance imaging (MRI) which requires extensive planning. T2 is sensitive to blood oxygenation and may be able to detect oxygenation differences between the left (LV) and right ventricles (RV) caused by L-R shunts. PURPOSE: To test the feasibility of routine T2 mapping to detect L-R shunts. STUDY TYPE: Retrospective. POPULATION: Patients with known L-R shunts (N = 27), patients with RV disease without L-R shunts (N = 21), and healthy volunteers (HV; N = 52). FIELD STRENGTH/SEQUENCE: 1.5 and 3 T/balanced steady-state free-precession (bSSFP) sequence (cine imaging), T2-prepared bSSFP sequence (T2 mapping), and velocity sensitized gradient echo sequence (phase-contrast MRI). ASSESSMENT: Aortic (Qs) and pulmonary (Qp) flow was measured by phase-contrast imaging, and the Qp/Qs ratio was calculated as a measure of shunt severity. T2 maps were used to measure T2 in the RV and LV and the RV/LV T2 ratio was calculated. Cine imaging was used to calculate RV end-diastolic volume index (RV-EDVi). STATISTICAL TESTS: Wilcoxon test, paired t-tests, Spearmen correlation coefficient, receiver operating curve (ROC) analysis. Significance level P < 0.05. RESULTS: The Qp/Qs and T2 ratios in L-R shunt patients (1.84 ± 0.84 and 0.89 ± 0.07) were significantly higher compared to those in patients with RV disease (1.01 ± 0.03 and 0.72 ± 0.10) and in HV (1.04 ± 0.04 and 0.71 ± 0.09). A T2 ratio of >0.78 showed a sensitivity, specificity, and negative predictive value of 100%, 73.9%, and 100%, respectively, for the detection of L-R shunts. The T2 ratio was strongly correlated with the severity of the shunt (r = 0.83). DATA CONCLUSION: RV/LV T2 ratio is an imaging biomarker that may be able to detect or rule-out L-R shunts. Such a diagnostic tool may prevent unnecessary phase-contrast acquisitions in cases with RV dilatation of unknown etiology. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 2.


Assuntos
Ventrículos do Coração , Imageamento por Ressonância Magnética , Aorta , Ventrículos do Coração/diagnóstico por imagem , Humanos , Estudos Retrospectivos
9.
Interact Cardiovasc Thorac Surg ; 34(4): 613-615, 2022 03 31.
Artigo em Inglês | MEDLINE | ID: mdl-34888682

RESUMO

Aortic reconstruction at the time of the comprehensive stage II (CSII) procedure can be complicated by compression within the aortopulmonary space resulting in airway or pulmonary artery narrowing. We describe our experience with 2 patients with hypoplastic left heart syndrome and pulmonary artery stenosis after the CSII procedure. Both patients underwent an aortic extension with a Hemashield interposition graft to open up the aortopulmonary space. The patients were discharged from the hospital. In all cases the aortopulmonary space was enlarged, and the pulmonary arteries and airway were free from compression. Aortic extension is an option to be considered in children with pulmonary artery compression who previously had a CSII procedure.


Assuntos
Síndrome do Coração Esquerdo Hipoplásico , Aorta/diagnóstico por imagem , Aorta/cirurgia , Criança , Humanos , Síndrome do Coração Esquerdo Hipoplásico/diagnóstico por imagem , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Cuidados Paliativos/métodos , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares
10.
Radiol Med ; 126(5): 737-743, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33394367

RESUMO

Central conducting lymphatics (CCLs) disorders represent a broad spectrum of clinical entities ranging from self-limiting traumatic leaks treated by conservative strategies, to complex lymphatic circulation abnormalities that are progressive and unresponsive to currently available treatments. Dynamic contrast-enhanced magnetic resonance lymphangiography (DCMRL) performed by intranodal injection of gadolinium-based contrast material is a recently developed technique which allows a minimally invasive evaluation of the CCL abnormalities providing a dynamic assessment of lymph flow and its pathways. In our institution, DCMRL is performed after bilateral cannulation of inguinal lymph nodes, using a MR protocol which includes volumetric 3D T2-SPACE (sampling perfection with application-optimized contrasts using different flip-angle evolution) and free-breathing respiratory navigated sequence and TWIST (time-resolved angiography with Interleaved stochastic trajectories) MR angiography sequence, during intranodal injection of paramagnetic contrast medium. Although DCMRL applications in clinical practice are still improving, a minimally invasive assessment of lymphatic pathways is particularly important both in pediatric patients with primitive lymphatic system disorders and in children with complex congenital heart disease associated with CCL impairment.


Assuntos
Doenças Linfáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Criança , Meios de Contraste , Feminino , Humanos , Masculino , Meglumina , Compostos Organometálicos
11.
J Thorac Imaging ; 36(3): W35-W51, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32205818

RESUMO

Systemic immune-mediated diseases (SID) are a large group of disorders characterized by complex inflammatory and autoimmune damage to various organs and tissues. Among the possible manifestations, SIDs may potentially involve each structure of the cardiopulmonary system. Each disease is characterized by a specific clinical presentation. Coronary artery disease, myocarditis, pericarditis, valvular disease, pulmonary arterial hypertension, and interstitial lung disease represent characteristic findings of cardiopulmonary involvement in these disorders and their prompt recognition is crucial for the diagnosis of SIDs and the patient's prognosis. In this setting, chest high-resolution computed tomography and cardiac magnetic resonance are the most important noninvasive techniques for the assessment of these diseases and their complications. The knowledge of various cardiac and pulmonary radiologic patterns increases the likelihood of diagnosing these disorders and can lead to improved understanding of the underlying pathophysiology to personalize the treatment for each patient.


Assuntos
Coração , Doenças Pulmonares Intersticiais , Humanos , Pulmão , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Tomografia Computadorizada por Raios X
12.
Updates Surg ; 72(4): 1115-1124, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32306275

RESUMO

Internal hernia (IH) represents a delayed complication of the laparoscopic Roux-en-Y gastric bypass (LRYGB) and it is historically difficult to identify preoperatively. Numerous CT signs were considered suggestive of IH but none of them is pathognomonic. In this study, we aim to evaluate the accuracy of CT in diagnosing IH, differentiating from non-specific abdominal pain. This can lead to a way of personalized medicine and improve the outcome of anti-obesity treatments. We retrospectively reviewed CT scans of 50 patients previously subjected to LRYGB procedure, with a clinical suspicion of IH. 3 groups of patients were identified: IH group (21 patients with a surgical confirmed IH), negative group (12 patients in whom IH was not confirmed at surgery), and control group (17 patients who were not surgically explored because of low/no suspicion of IH). We divided CT signs into three groups: "bowel loop signs", "vessel signs", and "venous congestion/stasis signs". The accuracy of CT in detecting IH was tested by comparing each sign, either individually or in combination, with the surgical findings. Statistical analysis showed that "vessel signs" (swirl sign, superior mesenteric vein beaking, mesenteric arteries, and veins branches inversion) present the highest distribution in patients with IH demonstrated at surgery, with a higher accuracy in case of simultaneous presence of two or three signs. CT imaging is highly accurate in diagnosing IH. Despite no single sign being pathognomonic, the combination of two or more signs, especially among the "vessels signs", can suggest the IH, even in pauci-symptomatic patients.


Assuntos
Dor Abdominal/diagnóstico por imagem , Anastomose em-Y de Roux/efeitos adversos , Anastomose em-Y de Roux/métodos , Derivação Gástrica/efeitos adversos , Derivação Gástrica/métodos , Hérnia Interna/diagnóstico por imagem , Hérnia Interna/etiologia , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Adulto , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
13.
J Gastrointestin Liver Dis ; 28: 213-224, 2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-31204402

RESUMO

Crohn's disease (CD) is a chronic inflammatory condition characterized by continuous mucosal damage and ongoing wound healing of the intestines. The fibrinolytic system is involved in early parts of the wound healing process. Fibrin is a key mediator of primary blood clot formation and is formed by cross-linking of fibrinogen. To gain insights into the dynamics of wound healing in CD patients we investigated the conversion of fibrinogen into fibrin by the pro-peptide FPA, the amount of factor XIII cross-linked fibrin and total fibrin clot. METHODS: Serum samples of 35 CD patients, 15 non-inflammatory bowel disease (non-IBD) patients and 39 age-matched healthy controls were analyzed for three novel neo-epitope markers: D-fragment and D-dimer, reflecting the degradation of total fibrin clot and factor XIII cross-linked fibrin, as well as FPA, reflecting synthesis of fibrin. RESULTS: Crohn's disease patients had a significantly lower D-dimer level (p=0.0001) compared to healthy controls. Crohn's disease and non-IBD patients had a significantly higher level of FPA (p<0.0001) and D-fragment/D-dimer ratio (p<0.0001 and p=0.02). FPA, D-dimer and D-fragment/D-dimer ratio could distinguish CD patients from healthy controls with area under the curve of 0.92 (95% CI 0.83-0.97), 0.78 (95% CI 0.67-0.87) and 0.85 (95% CI 0.75-0.93), respectively. CONCLUSION: Wound healing parameters were clearly changed in CD patients. FPA levels were higher in CD patients as compared to healthy controls, indicating more ongoing wound healing. D-dimer levels were lower in CD patients than in healthy controls, indicating impaired wound healing due to poor quality of factor XIII cross-linked fibrin and clot resolution.


Assuntos
Doença de Crohn/diagnóstico por imagem , Estudos de Casos e Controles , Doença de Crohn/sangue , Doença de Crohn/fisiopatologia , Endoscopia Gastrointestinal , Produtos de Degradação da Fibrina e do Fibrinogênio/metabolismo , Humanos , Mucosa Intestinal/fisiologia , Imageamento por Ressonância Magnética/métodos , Índice de Gravidade de Doença , Cicatrização/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...