Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 11(1): 14961, 2021 07 22.
Artigo em Inglês | MEDLINE | ID: mdl-34294757

RESUMO

Influenza and other respiratory viruses present a significant threat to public health, national security, and the world economy, and can lead to the emergence of global pandemics such as from COVID-19. A barrier to the development of effective therapeutics is the absence of a robust and predictive preclinical model, with most studies relying on a combination of in vitro screening with immortalized cell lines and low-throughput animal models. Here, we integrate human primary airway epithelial cells into a custom-engineered 96-device platform (PREDICT96-ALI) in which tissues are cultured in an array of microchannel-based culture chambers at an air-liquid interface, in a configuration compatible with high resolution in-situ imaging and real-time sensing. We apply this platform to influenza A virus and coronavirus infections, evaluating viral infection kinetics and antiviral agent dosing across multiple strains and donor populations of human primary cells. Human coronaviruses HCoV-NL63 and SARS-CoV-2 enter host cells via ACE2 and utilize the protease TMPRSS2 for spike protein priming, and we confirm their expression, demonstrate infection across a range of multiplicities of infection, and evaluate the efficacy of camostat mesylate, a known inhibitor of HCoV-NL63 infection. This new capability can be used to address a major gap in the rapid assessment of therapeutic efficacy of small molecules and antiviral agents against influenza and other respiratory viruses including coronaviruses.


Assuntos
Antivirais/farmacologia , Infecções por Coronavirus/virologia , Influenza Humana/virologia , Testes de Sensibilidade Microbiana/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Mucosa Respiratória/citologia , Brônquios/citologia , Brônquios/virologia , COVID-19/virologia , Técnicas de Cultura de Células/instrumentação , Linhagem Celular , Coronavirus/efeitos dos fármacos , Infecções por Coronavirus/tratamento farmacológico , Desenho de Equipamento , Ensaios de Triagem em Larga Escala/instrumentação , Humanos , Vírus da Influenza A/efeitos dos fármacos , Influenza Humana/tratamento farmacológico , Mucosa Respiratória/virologia , Infecções Respiratórias/tratamento farmacológico , Infecções Respiratórias/virologia , SARS-CoV-2/efeitos dos fármacos , Tratamento Farmacológico da COVID-19
2.
Lab Chip ; 18(13): 1844-1858, 2018 06 26.
Artigo em Inglês | MEDLINE | ID: mdl-29796561

RESUMO

Recapitulation of the tumor microenvironment is critical for probing mechanisms involved in cancer, and for evaluating the tumor-killing potential of chemotherapeutic agents, targeted therapies and immunotherapies. Microfluidic devices have emerged as valuable tools for both mechanistic studies and for preclinical evaluation of therapeutic agents, due to their ability to precisely control drug concentrations and gradients of oxygen and other species in a scalable and potentially high throughput manner. Most existing in vitro microfluidic cancer models are comprised of cultured cancer cells embedded in a physiologically relevant matrix, collocated with vascular-like structures. However, the recent emergence of immune checkpoint inhibitors (ICI) as a powerful therapeutic modality against many cancers has created a need for preclinical in vitro models that accommodate interactions between tumors and immune cells, particularly for assessment of unprocessed tumor fragments harvested directly from patient biopsies. Here we report on a microfluidic model, termed EVIDENT (ex vivo immuno-oncology dynamic environment for tumor biopsies), that accommodates up to 12 separate tumor biopsy fragments interacting with flowing tumor-infiltrating lymphocytes (TILs) in a dynamic microenvironment. Flow control is achieved with a single pump in a simple and scalable configuration, and the entire system is constructed using low-sorption materials, addressing two principal concerns with existing microfluidic cancer models. The system sustains tumor fragments for multiple days, and permits real-time, high-resolution imaging of the interaction between autologous TILs and tumor fragments, enabling mapping of TIL-mediated tumor killing and testing of various ICI treatments versus tumor response. Custom image analytic algorithms based on machine learning reported here provide automated and quantitative assessment of experimental results. Initial studies indicate that the system is capable of quantifying temporal levels of TIL infiltration and tumor death, and that the EVIDENT model mimics the known in vivo tumor response to anti-PD-1 ICI treatment of flowing TILs relative to isotype control treatments for syngeneic mouse MC38 tumors.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Modelos Biológicos , Microambiente Tumoral/imunologia , Animais , Carcinoma Pulmonar de Células não Pequenas/química , Carcinoma Pulmonar de Células não Pequenas/imunologia , Técnicas de Cultura de Células , Linhagem Celular Tumoral , Células Cultivadas , Desenho de Equipamento , Humanos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/química , Neoplasias Pulmonares/imunologia , Linfócitos/citologia , Linfócitos/metabolismo , Camundongos , Técnicas Analíticas Microfluídicas/métodos
4.
Lab Chip ; 17(1): 134-144, 2016 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-27901159

RESUMO

The drug development pipeline is severely limited by a lack of reliable tools for prediction of human clinical safety and efficacy profiles for compounds at the pre-clinical stage. Here we present the design and implementation of a platform technology comprising multiple human cell-based tissue models in a portable and reconfigurable format that supports individual organ function and crosstalk for periods of up to several weeks. Organ perfusion and crosstalk are enabled by a precision flow control technology based on electromagnetic actuators embedded in an arrayed format on a microfluidic platform. We demonstrate two parallel circuits of connected airway and liver modules on a platform containing 62 electromagnetic microactuators, with precise and controlled flow rates as well as functional biological metrics over a two week time course. Technical advancements enabled by this platform include the use of non-sorptive construction materials, enhanced scalability, portability, flow control, and usability relative to conventional flow control modes (such as capillary action, pressure heads, or pneumatic air lines), and a reconfigurable and modular organ model format with common fluidic port architecture. We demonstrate stable biological function for multiple pairs of airway-liver models for periods of 2 weeks in the platform, with precise control over fluid levels, temperature, flow rate and oxygenation in order to support relevant use cases involving drug toxicity, efficacy testing, and organ-organ interaction.


Assuntos
Microfluídica/métodos , Brônquios/citologia , Células Cultivadas , Técnicas de Cocultura , Citocromo P-450 CYP3A/metabolismo , Descoberta de Drogas , Células Epiteliais/citologia , Células Epiteliais/metabolismo , Hepatócitos/citologia , Hepatócitos/metabolismo , Humanos , Campos Magnéticos , Microfluídica/instrumentação , Microscopia de Fluorescência
5.
Lab Chip ; 16(17): 3227-34, 2016 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-27411972

RESUMO

Blood oxygenators provide crucial life support for patients suffering from respiratory failure, but their use is severely limited by the complex nature of the blood circuit and by complications including bleeding and clotting. We have fabricated and tested a multilayer microfluidic blood oxygenation prototype designed to have a lower blood prime volume and improved blood circulation relative to current hollow fiber cartridge oxygenators. Here we address processes for scaling the device toward clinically relevant oxygen transfer rates while maintaining a low prime volume of blood in the device, which is required for clinical applications in cardiopulmonary support and ultimately for chronic use. Approaches for scaling the device toward clinically relevant gas transfer rates, both by expanding the active surface area of the network of blood microchannels in a planar layer and by increasing the number of microfluidic layers stacked together in a three-dimensional device are addressed. In addition to reducing prime volume and enhancing gas transfer efficiency, the geometric properties of the microchannel networks are designed to increase device safety by providing a biomimetic and physiologically realistic flow path for the blood. Safety and hemocompatibility are also influenced by blood-surface interactions within the device. In order to further enhance device safety and hemocompatibility, we have demonstrated successful coating of the blood flow pathways with human endothelial cells, in order to confer the ability of the endothelium to inhibit coagulation and thrombus formation. Blood testing results provide confirmation of fibrin clot formation in non-endothelialized devices, while negligible clot formation was documented in cell-coated devices. Gas transfer testing demonstrates that the endothelial lining does not reduce the transfer efficiency relative to acellular devices. This process of scaling the microfluidic architecture and utilizing autologous cells to line the channels and mitigate coagulation represents a promising avenue for therapy for patients suffering from a range of acute and chronic lung diseases.


Assuntos
Materiais Biomiméticos/química , Biomimética/métodos , Gasometria/instrumentação , Endotélio Vascular/metabolismo , Desenho de Equipamento , Microfluídica/métodos , Oxigênio/metabolismo , Absorção Fisiológica , Biomimética/instrumentação , Células Cultivadas , Células Imobilizadas , Dimetilpolisiloxanos/química , Endotélio Vascular/citologia , Células Endoteliais da Veia Umbilical Humana/citologia , Células Endoteliais da Veia Umbilical Humana/metabolismo , Humanos , Teste de Materiais , Microfluídica/instrumentação , Oxigênio/sangue , Propriedades de Superfície
6.
Biomed Microdevices ; 11(3): 571-8, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19089621

RESUMO

The development and optimization of many new drug therapies requires long-term local delivery with controlled, but variable dosage. Current methods for chronic drug delivery have limited utility because they either cannot deliver drugs locally to a specific organ or tissue, do not permit changes in delivery rate in situ, or cannot be used in clinical trials in an untethered, wearable configuration. Here, we describe a small, self-contained system for liquid-phase drug delivery. This system enables studies lasting several months and infusion rates can be programmed and modified remotely. A commercial miniature pump is integrated with microfabricated components to generate ultralow flow rates and stroke volumes. Solutions are delivered in pulses as small as 370 nL, with pulses delivered at any interval of 1 min or longer. A unique feature of the system is the ability to infuse and immediately withdraw liquid, resulting in zero net volume transfer while compounds are exchanged by mixing and diffusion with endogenous fluid. We present in vitro results demonstrating repeatability of the delivered pulse volume for nearly 3 months. Furthermore, we present in vivo results in an otology application, infusing into the cochlea of a guinea pig a glutamate receptor antagonist, which causes localized and reversible changes in auditory sensitivity.


Assuntos
Sistemas de Liberação de Medicamentos , Antagonistas de Aminoácidos Excitatórios/farmacologia , Microfluídica/instrumentação , Microfluídica/métodos , Quinoxalinas/farmacologia , Potenciais de Ação/efeitos dos fármacos , Animais , Cóclea/cirurgia , Formas de Dosagem , Eletrônica , Desenho de Equipamento , Cobaias , Miniaturização , Emissões Otoacústicas Espontâneas/fisiologia , Receptores de Glutamato/metabolismo , Transmissão Sináptica/efeitos dos fármacos , Fatores de Tempo , Testes de Toxicidade Aguda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...