Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Biomed Chromatogr ; 26(11): 1399-407, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22345050

RESUMO

In the present study a simple, fast, sensitive and robust method to quantify mirtazapine in human plasma using quetiapine as the internal standard (IS) is described. The analyte and the IS were extracted from human plasma by a simple protein precipitation with methanol and were analyzed by high-performance liquid chromatography coupled to an electrospray tandem triple quadrupole mass spectrometer (HPLC-ESI-MS/MS). Chromatography was performed isocratically on a C(18), 5 µm analytical column and the run time was 1.8 min. The lower limit of quantitation was 0.5 ng/mL and a linear calibration curve over the range 0.5-150 ng/mL was obtained, showing acceptable accuracy and precision. This analytical method was applied in a relative bioavailability study in order to compare a test mirtazapine 30 mg single-dose formulation vs a reference formulation in 31 volunteers of both sexes. The study was conducted in an open randomized two-period crossover design and with a 14 day washout period. Since the 90% confidence interval for C(max) , AUC(last) and AUC(0-inf) were within the 80-125% interval proposed by the Food and Drug Administration and ANVISA (Brazilian Health Surveillance Agency), it was concluded that mirtazapine 30 mg/dose is bioequivalent to the reference formulation, according to both the rate and extent of absorption.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Mianserina/análogos & derivados , Espectrometria de Massas em Tandem/métodos , Adulto , Área Sob a Curva , Disponibilidade Biológica , Estudos Cross-Over , Dibenzotiazepinas/sangue , Estabilidade de Medicamentos , Feminino , Humanos , Modelos Lineares , Masculino , Mianserina/sangue , Mianserina/química , Mianserina/farmacocinética , Pessoa de Meia-Idade , Mirtazapina , Fumarato de Quetiapina , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização por Electrospray/métodos
2.
J Chromatogr B Analyt Technol Biomed Life Sci ; 879(31): 3728-34, 2011 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-22074958

RESUMO

In the present study a method to quantify chlorpromazine in human plasma using cyclobenzaprine as the internal standard (IS) is described. The analyte and the IS were extracted from human plasma by a liquid-liquid extraction with diethyl ether/dichloromethane (70/30, v/v) and analyzed by an ultra performance liquid chromatography (UPLC) coupled to an electrospray tandem triple quadrupole mass spectrometer in positive mode (UPLC-ES(+)-MS/MS). Chromatography was performed isocratically on an Aquity UPLC BEH C18 1.7 µm (50 mm × 2.1 mm i.d.) operating at 40°C. The mobile phase was a mixture of 65% water+1% formic acid and 35% of acetonitrile at a flow-rate of 0.5 mL/min. The lowest concentration quantified was 0.5 ng/mL and a linear calibration curve over the range 0.5-200 ng/mL was obtained, showing intra-assay precisions from 2.4 to 5.8%, and inter-assay precisions from 3.6 to 9.9%. The intra-assay accuracies ranged from 96.9 to 102.5%, while the inter-assay accuracies ranged from 94.1 to 100.3%. This analytical method was applied in a relative bioavailability study in order to compare a test chlorpromazine 100 mg simple dose formulation versus a reference in 57 volunteers of both sexes. The study was conducted in an open randomized two-period crossover design and with a fourteen days washout period. Plasma samples were obtained over a 144-h interval. Since the 90% CI for both C(max), AUC(last) and AUC(0-inf) were within the 80-125% interval proposed by the Food and Drug Administration and ANVISA, it was concluded that chlorpromazine 100 mg/dose was bioequivalent to the reference formulation, according to both the rate and extent of absorption.


Assuntos
Clorpromazina/sangue , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Adolescente , Adulto , Amitriptilina/análogos & derivados , Área Sob a Curva , Disponibilidade Biológica , Clorpromazina/farmacocinética , Estudos Cross-Over , Estabilidade de Medicamentos , Feminino , Humanos , Limite de Detecção , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Distribuição Aleatória , Reprodutibilidade dos Testes
3.
J Chromatogr B Analyt Technol Biomed Life Sci ; 879(3-4): 236-42, 2011 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-21233029

RESUMO

In the present study, a novel, fast, sensitive and robust method to quantify budesonide in human plasma using 3-keto-desogestrel as the internal standard (IS) is described. The analyte and the IS were extracted from human plasma by liquid-liquid extraction (LLE) using ether. Extracted samples were analyzed by high performance liquid chromatography coupled to Atmospheric pressure photoionization tandem mass spectrometry (HPLC-APPI-MS/MS). Chromatography was performed isocratically on a C18, 5 µm analytical column. The temperature of the autosampler was kept at 6 °C and the run time was 4.00 min. A linear calibration curve over the range 7.5-1000 pg ml⁻¹ was obtained and the lowest concentration quantified was 7.5 pg ml⁻¹, demonstrating acceptable accuracy and precision. This analytical method was applied in a relative bioavailability study in order to compare a test budesonide 64 µg/dose nasal spray formulation vs. a reference 64 µg/dose nasal spray formulation (Budecort Aqua) in 48 volunteers of both sexes. The study was conducted in an open randomized two-period crossover design and with a one-week washout period. Plasma samples were obtained over a 14 h interval. Since the 90% CI for both C(max), AUC(last) and AUC(0-inf) were within the 80-125% interval proposed by the Food and Drug Administration and ANVISA, it was concluded that budesonide 64 µg/dose nasal spray was bioequivalent to Budecort Acqua® 64 µg/dose nasal spray, according to both the rate and extent of absorption.


Assuntos
Budesonida/farmacocinética , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Adolescente , Adulto , Disponibilidade Biológica , Broncodilatadores/administração & dosagem , Broncodilatadores/sangue , Broncodilatadores/farmacocinética , Budesonida/administração & dosagem , Budesonida/sangue , Estudos Cross-Over , Desogestrel/sangue , Estabilidade de Medicamentos , Feminino , Humanos , Análise dos Mínimos Quadrados , Masculino , Pessoa de Meia-Idade , Sprays Nasais , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Equivalência Terapêutica
4.
Biomed Chromatogr ; 24(7): 774-81, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19924675

RESUMO

In the present study a fast, sensitive and robust validated method to quantify chlorpheniramine in human plasma using brompheniramine as internal standard (IS) is described. The analyte and the IS were extracted from plasma by LLE (diethyl ether-dichloromethane, 80:20, v/v) and analyzed by HPLC-ESI-MS/MS. Chromatographic separation was performed using a gradient of methanol from 35 to 90% with 2.5 mm NH(4)OH on a Gemini Phenomenex C(8) 5 microm column (50 x 4.6 mm i.d.) in 5.0 min/run. The method fitted to a linear calibration curve (0.05-10 ng/mL, R > 0.9991). The precision (%CV) and accuracy ranged, respectively: intra-batch from 1.5 to 6.8% and 99.1 to 106.6%, and inter-batch from 2.4 to 9.0%, and 99.9 to 103.1%. The validated bioanalytical procedure was used to assess the comparative bioavailability in healthy volunteers of two dexchlorpheniramine 2.0 mg tablet formulations (test dexchlorpheniramine, Eurofarma, and reference Celestamine, Schering-Plough). The study was conducted using an open, randomized, two-period crossover design with a 2 week washout interval. Since the 90% confidence interval for C(max) and AUC ratios were all within the 80-125% interval proposed by ANVISA and FDA, it was concluded that test and reference formulations are bioequivalent concerning the rate and the extent of absorption.


Assuntos
Clorfeniramina/sangue , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Disponibilidade Biológica , Clorfeniramina/farmacocinética , Clorfeniramina/farmacologia , Humanos , Espectrometria de Massas por Ionização por Electrospray/métodos
5.
Arzneimittelforschung ; 59(7): 335-44, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19728560

RESUMO

A specific, fast and sensitive high performance liquid chromatography (HPLC) coupled to atmospheric pressure photoionization (APPI) tandem mass spectrometric (LC-MS/MS) assay was developed for the determination of cyproterone (CYP) acetate (CAS 427-51-0) in human plasma. The retention times were 3.26 and 2.90 min for CYP acetate and its internal standard (I. S.) finasteride (FIN), respectively. The overall mean recovery, using liquid/liquid extraction, was found to be 109.0, 107.7 and 100.3%, for low, medium and high concentrations, respectively. Calibration curves were linear in the concentration range of 0.1-50.0 ng/ml, and the lower limit of quantification (LLOQ) was 0.1 ng/ml. The LLOQ, 0.1 ng/ml, was sensitive enough for detecting terminal phase concentrations of the drug. Inter-batch precision of the method ranged from 2.2 to 5.55%, while Inter-batch accuracy ranged from 95.5 to 100.0%. Intra-batch precision ranged from 1.8 to 5.6%, while Intra-batch accuracy ranged from 92.0 to 99.4% at concentrations of 0.3 ng/ml, 20.0 and 40.0 ng/ml. The developed method was applied to a bioequivalenc study of CYP acetate in a group of 44 female volunteers at a single oral dose of a 2 mg tablet, in a combination of ethinylestradiol/CYP acetate (0.25/2 mg). The plasma concentration of CYP acetate did not differ significantly after administration of both formulations (test formulation and the reference one). The geometric mean and respective 90% CI of CYP acetate test/reference percent ratios were 90.66% (84.39-97.40%) for Cmax and 96.20% (90.45-102.33%) for AUC0-t.


Assuntos
Antagonistas de Androgênios/sangue , Acetato de Ciproterona/sangue , Adulto , Antagonistas de Androgênios/farmacocinética , Área Sob a Curva , Cromatografia Líquida de Alta Pressão , Estudos Cross-Over , Acetato de Ciproterona/farmacocinética , Método Duplo-Cego , Feminino , Congelamento , Humanos , Pessoa de Meia-Idade , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , Soluções , Manejo de Espécimes , Espectrometria de Massas em Tandem , Adulto Jovem
6.
J Chromatogr B Analyt Technol Biomed Life Sci ; 877(29): 3601-9, 2009 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-19773204

RESUMO

In the present study, a novel, fast, sensitive and robust method to quantify ethinylestradiol in human plasma using 17alpha-ethinylestradiol-d4 as the internal standard (IS) is described. The analyte and the IS were extracted from acidified plasma by liquid-liquid extraction (LLE) using diethyl ether-hexane followed by online solid phase extraction (SPE) using online C18 cartridges. Extracted samples were analyzed by high-performance liquid chromatography coupled to atmospheric pressure photoionization tandem mass spectrometry (HPLC-APPI-MS/MS). Chromatography was performed isocratically on a C18, 5 microm analytical column. The method had a chromatographic run time of 2.50 min and a linear calibration curve over the range 5-500 pg ml(-1) (r(2)>0.9992). The lowest concentration quantified was 5 pg ml(-1), demonstrating acceptable accuracy and precision. The intra-assay precisions ranged from 2.1 to 14.6%, while inter-assay precisions ranged from 4.4 to 11.4%. The intra-assay accuracies ranged from 94.6 to 103.8%, while the inter-assay accuracies ranged from 98.9 to 101.6%. The recovery of ethinylestradiol was determined as part of the assay validation process and was 73.1 and 79.0% for the concentrations 15 and 375 pg ml(-1), respectively. Short-term stability showed that ethinylestradiol was stable in plasma for at least 19 h at room temperature or for at least 385 days when stored at -20 degrees C. In the study of bioequivalence conducted in Brazil, healthy volunteers received two ethinylestradiol 0.035 mg tablet formulations using an open, randomized, two-period crossover design with a 2-week washout interval. Since the 90% confidence interval for C(max) and area under the curve ratios were all inside the 80-125% interval proposed by the US Food and Drug Administration, it was concluded that the two ethinylestradiol formulations are bioequivalent with respect to both the rate and the extent of absorption.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Etinilestradiol/sangue , Etinilestradiol/farmacocinética , Espectrometria de Massas em Tandem/métodos , Humanos , Reprodutibilidade dos Testes
7.
Arq Bras Endocrinol Metabol ; 51(6): 950-5, 2007 Aug.
Artigo em Português | MEDLINE | ID: mdl-17934662

RESUMO

OBJECTIVE: To compare the bioavailability of two glimepiride 4-mg tablet formulation in 26 healthy volunteers of both sexes. MATERIAL AND METHODS: The study was conducted open with randomized two-period crossover design and a 14-day washout period. Samples were obtained over a 48-hour interval. Glimepiride concentrations were analyzed by LC-MS-MS. From the glimepiride plasma concentration versus time curves the following pharmacokinetic parameters were obtained: AUC(0-last), AUC(0-t), AUC(0-infinity), Ke, T1/2, Cmax, and Tmax. RESULTS: Geometric mean of Glimepirida/Amaryl 4 mg was 102.35% for AUC(0-t), 102.35% for AUC(0-infinity) and 99.31% for Cmax. The 90% CI was 92.62-109.55%; 95.62-109.55% e 88.60-111.32%, respectively. CONCLUSION: Since the 90% CI for both Cmax, AUC(0-t), and AUC(0-infinity) were within the interval of 80-125%, it was concluded that both formulations were bioequivalent, according to both the rate and extent of absorption.


Assuntos
Hipoglicemiantes/farmacocinética , Compostos de Sulfonilureia/farmacocinética , Adulto , Disponibilidade Biológica , Cápsulas , Estudos Cross-Over , Feminino , Humanos , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/sangue , Masculino , Valores de Referência , Compostos de Sulfonilureia/administração & dosagem , Compostos de Sulfonilureia/sangue , Equivalência Terapêutica
8.
Arq. bras. endocrinol. metab ; 51(6): 950-955, ago. 2007. graf, tab
Artigo em Português | LILACS | ID: lil-464287

RESUMO

OBJETIVO: Comparar a biodisponibilidade de duas formulações de glimepirida em 26 voluntários sadios de ambos os sexos. MATERIAL E MÉTODOS: O estudo foi aberto, cruzado e randomizado com dois períodos e wash out de 14 dias. As amostras foram obtidas em um intervalo de 48 horas. As concentrações de glimepirida foram analisadas por HPLC MS/MS. Das curvas de concentração de glimepirida no plasma versus tempo, foram obtidos os seguintes parâmetros farmacocinéticos: ASC(0-t), ASC(0-∞), Cmax, Ke, Tmax e T1/2. RESULTADOS: A razão entre as média geométricas de Glimepirida/Amaryl® 4 mg foi de 102,35 por cento para ASC(0-t); 102,35 por cento para ASC(0-∞) e 99,31 por cento para Cmax. Os intervalos de confiança de 90 por cento (IC 90 por cento) foram de 92,62-109,55 por cento; 95,62-109,55 por cento e 88,60-111,32 por cento, respectivamente. CONCLUSÃO: Como o IC 90 por cento para Cmax, ASC(0-t) e ASC(0-∞) estava dentro do intervalo de 80-125 por cento, concluiu-se que ambas as formulações foram bioequivalentes de acordo com o grau e a extensão de sua absorção.


OBJECTIVE: To compare the bioavailability of two glimepiride 4-mg tablet formulation in 26 healthy volunteers of both sexes. MATERIAL AND METHODS: The study was conducted open with randomized two-period crossover design and a 14-day washout period. Samples were obtained over a 48-hour interval. Glimepiride concentrations were analyzed by LC-MS-MS. From the glimepiride plasma concentration versus time curves the following pharmacokinetic parameters were obtained: AUC(0-last), AUC(0-t), AUC(0-∞), Ke, T1/2, Cmax, and Tmax. RESULTS: Geometric mean of Glimepirida/Amaryl® 4 mg was 102.35 percent for AUC(0-t), 102.35 percent for AUC(0-∞) and 99.31 percent for Cmax. The 90 percent CI was 92.62-109.55 percent; 95.62-109.55 percent e 88.60-111.32 percent, respectively. CONCLUSION: Since the 90 percent CI for both Cmax, AUC(0-t), and AUC(0-∞) were within the interval of 80-125 percent, it was concluded that both formulations were bioequivalent, according to both the rate and extent of absorption.


Assuntos
Adulto , Feminino , Humanos , Masculino , Hipoglicemiantes/farmacocinética , Compostos de Sulfonilureia/farmacocinética , Disponibilidade Biológica , Cápsulas , Estudos Cross-Over , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/sangue , Valores de Referência , Compostos de Sulfonilureia/administração & dosagem , Compostos de Sulfonilureia/sangue , Equivalência Terapêutica
9.
Artigo em Inglês | MEDLINE | ID: mdl-16203182

RESUMO

An analytical method based on liquid chromatography with positive ion electrospray ionization (ESI) coupled to tandem mass spectrometry detection (LC-MS/MS) was developed for the determination of Verapamil in human plasma using Metoprolol as the internal standard. The analyte and internal standard were extracted from the plasma samples by liquid-liquid extraction and chromatographed on a C(8) analytical column. The mobile phase consisted of methanol-water (70:30; v/v)+12 mM formic acid. The method had a chromatographic total run time of 3.5 min and was linear within the range 1.00-500 ng/mL. Detection was carried out on a Micromass Quattro Ultima tandem mass spectrometer by multiple reaction monitoring (MRM). The intra-run imprecision was less than 5.1% calculated from the quality control (QC) samples, and 16.3% from the limit of quantification (LOQ). The accuracy determined from QC samples were between 92.9 and 103.1%, and 95.2 and 115.3% from LOQ. Concerning the inter-batch analysis, the imprecision was less than 5.8% and 17.3% from QC samples and LOQ, respectively. The accuracy varied between 98.2 and 100.8% from QC and it was 103.1% from LOQ. The protocol herein described was employed in a bioequivalence study of two tablet formulations of Verapamil.


Assuntos
Cromatografia Líquida/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Equivalência Terapêutica , Verapamil/sangue , Estabilidade de Medicamentos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Verapamil/farmacocinética
10.
Arzneimittelforschung ; 55(7): 382-6, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16080277

RESUMO

OBJECTIVE: To assess the bioequivalence of gemfibrozil (CAS 25812-30-0) 900 mg tablet formulation from EMS Farmaceutica as test formulation versus a 900 mg tablet formulation as reference in 36 healthy volunteers of both sexes. METHODS: The study was conducted using an open, randomized, two-period crossover design with a 1-week washout interval. Plasma samples were obtained over a 24-h period. Plasma gemfibrozil concentrations were analyzed by liquid chromatography coupled to tandem mass spectrometry (LC-MS-MS) with negative ion electrospray ionization using multiple reaction monitoring (MRM). From the gemfibrozil plasma concentration vs time curves, the following pharmacokinetic parameters were obtained: AUClast, AUC(0-inf) and Cmax. RESULTS: The limit of quantification was 0.05 microg/mL for plasma gemfibrozil analysis. The geometric mean and respective 90% confidence interval (CI) of Test/Reference percent ratios were 90.29 (81.39-100.17) for Cmax, 96.26 (90.33-102.59) for AUClast, 96.04 (90.21-102.23) for AUC(0-24 h) and 96.62 (90.82-102.78) for AUC(0-infinity). CONCLUSION: Since the 90% CI for AUClast, AUC(0-inf) and Cmax, ratios were within the 80-125% interval proposed by the U.S. FDA, it was concluded that gemfibrozil 900 mg tablet (test formulation) was bioequivalent to the 900 mg tablet reference formulation for both rate and extent of absorption.


Assuntos
Genfibrozila/farmacocinética , Hipolipemiantes/farmacocinética , Adolescente , Adulto , Área Sob a Curva , Disponibilidade Biológica , Química Farmacêutica , Cromatografia Líquida de Alta Pressão , Estudos Cross-Over , Feminino , Genfibrozila/administração & dosagem , Humanos , Hipolipemiantes/administração & dosagem , Masculino , Espectrometria de Massas , Pessoa de Meia-Idade , Comprimidos
11.
J Chromatogr B Analyt Technol Biomed Life Sci ; 822(1-2): 253-62, 2005 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-16005691

RESUMO

A rapid, sensitive and specific method to quantify carvedilol in human plasma using metoprolol as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid-liquid extraction using a diethyl-ether solvent. After removed and dried the organic phase, the extracts were reconstituted with a fixed volume of acetonitrile-water (50/50; v/v). The extracts were analyzed by a high performance liquid chromatography coupled to electrospray tandem mass spectrometry (HPLC-MS/MS). Chromatography was performed isocratically on Alltech Prevail C18 5 microm analytical column, (150 mm x 4.6 mm i.d.). The method had a chromatographic run time of 3.5 min and a linear calibration curve over the range 0.1-200 ng ml(-1) (r2>0.997992). The limit of quantification was 0.1 ng ml(-1). This HPLC-MS/MS procedure was used to assess the bioequivalence of two carvedilol 25 mg tablet formulations (carvedilol test formulation from Laboratórios Biosintética Ltda and Coreg from Roche Químicos e Farmacêuticos S.A standard reference formulation). A single 25 mg dose of each formulation was administered to healthy volunteers. The study was conducted using an open, randomized, two-period crossover design with a 2-week wash-out interval. Since the 90% CI for C(max) and AUCs ratios were all inside the 80-125% interval proposed by the US Food and Drug Administration Agency, it was concluded that carvedilol formulation elaborated by Laboratórios Biosintética Ltda is bioequivalent to Coreg formulation for both the rate and the extent of absorption.


Assuntos
Antagonistas Adrenérgicos beta/farmacocinética , Carbazóis/sangue , Carbazóis/farmacocinética , Cromatografia Líquida de Alta Pressão/métodos , Propanolaminas/sangue , Propanolaminas/farmacocinética , Espectrometria de Massas por Ionização por Electrospray/métodos , Carvedilol , Humanos , Sensibilidade e Especificidade , Equivalência Terapêutica
12.
J Mass Spectrom ; 39(12): 1562-9, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15578632

RESUMO

A rapid, sensitive and specific method to quantify ticlopidine in human plasma using clopidogrel as the internal standard (IS) is described. The analyte and the IS were extracted from acidified plasma by liquid-liquid extraction using diethyl ether-hexane (80 : 20, v/v). The extracts were analyzed by high-performance liquid chromatography coupled to electrospray tandem mass spectrometry (HPLC/MS/MS). Chromatography was performed isocratically on a Jones Genesis C(8) 4 microm analytical column (150 x 4.1 mm i.d.). The method had a chromatographic run time of 3.0 min and a linear calibration curve over the range 1.0-1000 ng ml(-1) (r(2) > 0.999427). The limit of quantification was 1.0 ng ml(-1). This HPLC/MS/MS procedure was used to assess the bioequivalence of two ticlopidine 250 mg tablet formulations (ticlopidine test formulation from Apotex do Brasil, Brazil, and Ticlid from Sanofi-Synthelabo, standard reference formulation). A single 250 mg dose of each formulation was administered to healthy volunteers. The study was conducted using an open, randomized, two-period crossover design with a 2 week washout interval. Since the 90% confidence interval for C(max) and area under the curve ratios were all inside the 80-125% interval proposed by the US Food and Drug Administration, it was concluded that ticlopidine formulation from Apotex do Brasil is bioequivalent to Ticlid formulation with respect to both the rate and the extent of absorption.


Assuntos
Ticlopidina/sangue , Cromatografia Líquida de Alta Pressão/métodos , Humanos , Inibidores da Agregação Plaquetária/sangue , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização por Electrospray/métodos , Equivalência Terapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...