Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Cardiol ; 203: 451-458, 2023 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-37540903

RESUMO

Gender-related differences have been reported in patients who underwent pulmonary vein isolation (PVI). Atrial substrate plays a role in the outcomes after ablation but gender-related differences in atrial substrate have never been described in detail. We sought to analyze gender-related differences in atrial remodeling (spontaneous low-voltage zones [LVZs]) and their clinical relevance after PVI. We conducted a prospective multicenter study, including consecutive patients who underwent first PVI-only atrial fibrillation (AF) ablation. LVZs were analyzed on high-density electroanatomical maps collected with multipolar catheter, before PVI. In total, 262 patients (61 ± 11 years, 31% female, 50% persistent AF) were followed for 28 months. In women, LVZs were larger (10% vs 4% of left atrial surface [p <0.001]) and female gender was independently associated with fourfold higher risk of having advanced (LVZ > 15%) atrial remodeling (odds ratio 4.56, p <0.001). AF recurrence-free survival was not different between men and women (log-rank p = 0.2). Although LVZs were independently associated higher AF recurrences at multivariate analysis (hazard ratio [HR] 1.2, p = 0.038), female gender was not (HR 1.4, p = 0.211). Specifically, the LVZ cutoff to predict outcomes was different in men and women: >5% in men (HR 3.0, p <0.001), >15% in women (HR 2.7, p = 0.02). In conclusion, women have more widespread LVZ in all left atrial regions. Despite more extensive atrial remodeling, the AF recurrence rate is similar in men and women, and LVZs become prognostic in women only at high burden (>15%). LVZs seem to have a different prognostic role in men and women.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Feminino , Estudos Prospectivos , Resultado do Tratamento , Átrios do Coração , Veias Pulmonares/cirurgia
2.
Heart Rhythm ; 20(5): 658-665, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36640853

RESUMO

BACKGROUND: The benefit of an anterior mitral line (AML) in patients with persistent atrial fibrillation (AF) and anterior atrial scar undergoing ablation has never been investigated. OBJECTIVE: The purpose of this study was to evaluate the outcomes of AML in addition to standard treatment compared to standard treatment alone (no AML) in this subset of patients. METHODS: Patients with persistent AF and anterior low-voltage zone (LVZ) treated with AML in 3 centers were retrospectively enrolled. The patients were matched in 1:1 fashion with patients having persistent AF and anterior LVZ who underwent conventional ablation in the same centers. Matching parameters were age, LVZ burden, and repeated ablation. Primary endpoint was AF/atrial tachycardia (AT) recurrence. RESULTS: One hundred eight-six patients (age 66 ± 9 years; 34% women) were selected and divided into 2 matched groups. Bidirectional conduction block was achieved in 95% of AML. After median follow-up of 2 years, AF/AT recurrence occurred in 29% of the patients in the AML group vs 48% in the no AML group (log-rank P = .024). On Cox regression multivariate analysis, left atrial volume (hazard ratio [HR] 1.03; P = .006) and AML (HR 0.46; P = .003) were significantly associated with the primary endpoint. On univariate logistic regression, lower body mass index, older age, extensive anterior LVZ, and position of the left atrial activation breakthrough away from the AML were associated with first-pass AML block. CONCLUSION: In this retrospective matched analysis of patients with persistent AF and anterior scar, AML in addition to standard treatment was associated with improved AF/AT-free survival compared to standard treatment alone.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Cicatriz/diagnóstico , Cicatriz/etiologia , Resultado do Tratamento , Técnicas Eletrofisiológicas Cardíacas , Taquicardia , Recidiva , Veias Pulmonares/cirurgia
3.
J Am Heart Assoc ; 12(1): e027795, 2023 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-36565183

RESUMO

Background Left atrial substrate may have mechanistic relevance for ablation of atrial fibrillation (AF). We sought to analyze the relationship between low-voltage zones (LVZs), transition zones, and AF recurrence in patients undergoing pulmonary vein isolation. Methods and Results We conducted a prospective multicenter study on consecutive patients undergoing pulmonary vein isolation-only approach. LVZs and transition zones (0.5-1 mV) were analyzed offline on high-density electroanatomical maps collected before pulmonary vein isolation. Overall, 262 patients (61±11 years, 31% female) with paroxysmal (130 pts) or persistent (132 pts) AF were included. After 28 months of follow-up, 73 (28%) patients experienced recurrence. An extension of more than 5% LVZ in paroxysmal AF and more than 15% in persistent AF was associated with recurrence (hazard ratio [HR], 4.4 [95% CI, 2.0-9.8], P<0.001 and HR, 1.9 [95% CI, 1.1-3.7], P=0.04, respectively). Significant association was found between LVZs and transition zones and between LVZs and left atrial volume index (LAVI) (both P<0.001). Thirty percent of patients had significantly increased LAVI without LVZs. Eight percent of patients had LVZs despite normal LAVI. Older age, female sex, oncological history, and increased AF recurrence characterized the latter subgroup. Conclusions In patients undergoing first pulmonary vein isolation, the impact of LVZs on outcomes occurs with lower burden in paroxysmal than persistent AF, suggesting that not all LVZs have equal prognostic implications. A proportional area of moderately decreased voltages accompanies LVZs, suggesting a continuous substrate instead of the dichotomous division of healthy or diseased tissue. LAVI generally correlates with LVZs, but a small subgroup of patients may present with disproportionate atrial remodeling, despite normal LAVI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Feminino , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Ablação por Cateter/métodos , Recidiva
4.
Circ Arrhythm Electrophysiol ; 8(6): 1342-50, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26383774

RESUMO

BACKGROUND: In an experimental model, variable and intermittent contact force (CF) resulted in a significant decrease in lesion volume. In humans, variability of CF during pulmonary vein isolation has not been characterized. METHODS AND RESULTS: In 20 consecutive patients undergoing CF-guided circumferential pulmonary vein isolation, 914 radiofrequency applications (530 in sinus rhythm and 384 in atrial fibrillation) were analyzed. The variability of the 60% CF range (CF(60%)) was 17±9.6 g. Hundred seventy-one (19%) applications were delivered with constant, 717 (78%) with variable, and 26 (3%) with intermittent CF. The mean CF and force-time integral were significantly higher during applications with variable than with intermittent or constant CF. There was no significant difference in CF variability, CF(60%) variability, and force-time integral between applications delivered in sinus rhythm and atrial fibrillation. The main reasons for CF variability were systolo-diastolic heart movement (29%) and respiration (27%). In 10 additional patients, during adenosine-induced atrioventricular block, the minimum CF significantly increased at 19 sites (5.3±4.4 versus 13.4±5.9 g; P<0.001) and at 16 sites intermittent or variable CF became constant. At only 1 site systolo-diastolic movement remained the main reason for variable CF. CONCLUSIONS: CF during pulmonary vein isolation remains highly variable despite efforts to optimize contact. CF and CF parameters were similar during sinus rhythm and atrial fibrillation. The main reasons for CF variability are systolo-diastolic heart movement and respiration. The systolo-diastolic peaks and nadirs of CF are because of ventricular contractions at the large majority of pulmonary vein isolation sites.


Assuntos
Fibrilação Atrial/cirurgia , Função Atrial , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Frequência Cardíaca , Contração Miocárdica , Veias Pulmonares/cirurgia , Transdutores de Pressão , Função Ventricular , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...