Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Hematology ; 20(1): 31-8, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24666187

RESUMO

OBJECTIVES: Paroxysmal nocturnal hemoglobinuria (PNH) is an acquired clonal stem cell disorder characterized by partial or absolute deficiency of glycophosphatidyl-inositol (GPI) anchor-linked surface proteins on blood cells. A lack of precise diagnostic standards for flow cytometry has hampered useful comparisons of data between laboratories. We report data from the first study evaluating the reproducibility of high-sensitivity flow cytometry for PNH in Russia. METHODS: PNH clone sizes were determined at diagnosis in PNH patients at a central laboratory and compared with follow-up measurements in six laboratories across the country. Analyses in each laboratory were performed according to recommendations from the International Clinical Cytometry Society (ICCS) and the more recent 'practical guidelines'. Follow-up measurements were compared with each other and with the values determined at diagnosis. RESULTS: PNH clone size measurements were determined in seven diagnosed PNH patients (five females, two males: mean age 37 years); five had a history of aplastic anemia and three (one with and two without aplastic anemia) had severe hemolytic PNH and elevated plasma lactate dehydrogenase. PNH clone sizes at diagnosis were low in patients with less severe clinical symptoms (0.41-9.7% of granulocytes) and high in patients with severe symptoms (58-99%). There were only minimal differences in the follow-up clone size measurement for each patient between the six laboratories, particularly in those with high values at diagnosis. CONCLUSIONS: The ICCS-recommended high-sensitivity flow cytometry protocol was effective for detecting major and minor PNH clones in Russian PNH patients, and showed high reproducibility between laboratories.


Assuntos
Anemia Aplástica/sangue , Citometria de Fluxo/métodos , Hemoglobinúria Paroxística/sangue , Adulto , Anemia Aplástica/patologia , Estudos de Coortes , Feminino , Hemoglobinúria Paroxística/patologia , Humanos , Masculino , Reprodutibilidade dos Testes , Federação Russa
2.
Curr Protoc Cytom ; 69: 8.14.1-8.14.10, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-24984965

RESUMO

This method makes it possible to measure the fluorescence of a DNA probe in cells with known division number and targeted surface antigen. In fact, this method is a combination or consistent application of three other methods: cell tracking by vital dye, surface immunophenotyping, and flow-FISH. The idea in developing this method was to study telomere length changes in cells with known surface antigen after every new cell division. First, the in vitro cell culturing and staining with CFSE vital dye are performed. Then, cells are stained with surface MAbs labeled with biotin, followed by incubation with streptavidin-labeled fluorochrome. After that, cells are fixed with BS(3) reagent followed by the flow-FISH procedure with PNA-probe complementary to telomere DNA repeats. Finally, in one tube, it is possible to determine telomere length in surface antigen-labeled cells that have made the exact same number of divisions after incubation.


Assuntos
Divisão Celular/fisiologia , Sondas de DNA/química , Corantes Fluorescentes/química , Hibridização in Situ Fluorescente/métodos , Telômero/metabolismo , Animais , Sondas de DNA/genética , Humanos , Telômero/genética
3.
J Theor Biol ; 290: 1-6, 2011 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-21920371

RESUMO

Though flow cytometry provides the entire distribution of cellular fluorescence (i.e., "fluorescence profile"), only mean fluorescence data are usually considered in studies of ligand-receptor binding. In this study, we presented a method of the treatment of the temporal evolution of the whole fluorescence profile with a comprehensive statistical approach extended to the reversible binding case. The method was demonstrated in the study of the 1D3 IgM monoclonal antibodies binding to FcγRIIIb receptors (CD16b) on neutrophils. Kinetic experiments were carried out using a FACSCalibur (Becton Dickinson, USA) flow cytometer. For each of four donors, we obtained the distribution of the number of FcγRIIIb surface receptors for neutrophils and the rate constants per receptor: the association rate constant of (2.7±0.4)×10(7) M(-1) min(-1), and the dissociation rate constant of (1.3±0.4)×10(-1) min(-1). Based on the obtained values, the size of the receptor reaction site was estimated at approximately 1 nm. It was found, that cell receptors distributions differed sufficiently between donors in mean and the skewness values, whereas the coefficient of variation (i.e., the ratio of the standard deviation to the mean) did not vary significantly.


Assuntos
Imunoglobulina M/sangue , Modelos Imunológicos , Neutrófilos/imunologia , Receptores de IgG/sangue , Algoritmos , Anticorpos Monoclonais/metabolismo , Sítios de Ligação de Anticorpos/imunologia , Citometria de Fluxo/métodos , Proteínas Ligadas por GPI/sangue , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...