Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Comput Biol Med ; 179: 108828, 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38996554

RESUMO

Transcatheter aortic heart valve thrombosis (THVT) affects long-term valve durability, transvalvular pressure gradient and leaflet mobility. In this study, we conduct high-fidelity fluid-structure interaction simulations to perform Lagrangian particle tracing in a generic model with larger aortic diameters (THVT model) with and without neo-sinus which is compared to a model of unaffected TAVI patients (control model). Platelet activation indices are computed for each particle to assess the risk of thrombus formation induced by high shear stresses followed by flow stagnation. Particle tracing indicates that fewer particles contribute to sinus washout of the THVT model with and without neo-sinus compared to the control model (-34.9%/-34.1%). Stagnating particles in the native sinus of the THVT model show higher platelet activation indices than for the control model (+39.6% without neo-sinus, +45.3% with neo-sinus). Highest activation indices are present for particles stagnating in the neo-sinus of the larger aorta representing THVT patients (+80.2% compared to control). This fluid-structure interaction (FSI) study suggests that larger aortas lead to less efficient sinus washout in combination with higher risk of platelet activation among stagnating particles, especially within the neo-sinus. This could explain (a) a higher occurrence of thrombus formation in transcatheter valves compared to surgical valves without neo-sinus and (b) the neo-sinus as the prevalent region for thrombi in TAV. Pre-procedural identification of larger aortic roots could contribute to better risk assessment of patients and improved selection of a patient-specific anti-coagulation therapy.

2.
APL Bioeng ; 7(4): 046120, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38125699

RESUMO

The etiology of transcatheter heart valve thrombosis (THVT) and the relevance of the aortic root geometry on the occurrence of THVT are largely unknown. The first aim of this pilot study is to identify differences in aortic root geometry between THVT patients and patients without THVT after transcatheter aortic valve implantation (TAVI). Second, we aim to investigate how the observed difference in aortic diameters affects the aortic flow using idealized computational geometric models. Aortic dimension was assessed using pre-TAVI multi-detector computed tomography scans of eight patients with clinical apparent THVT and 16 unaffected patients (two for each THVT patient with same valve type and size) from the Bern-TAVI registry. Among patients with THVT the right coronary artery height was lower (-40%), and sinotubular junction (STJ) and ascending aorta (AAo) diameters tended to be larger (9% and 14%, respectively) compared to the unaffected patients. Fluid-structure interaction (FSI) in two idealized aortic models with the observed differences in STJ and AAo diameter showed higher backflow rate at the STJ (+16%), lower velocity magnitudes in the sinus (-5%), and higher systolic turbulent dissipation rate in the AAo (+8%) in the model with larger STJ and AAo diameters. This pilot study suggests a direct effect of the aortic dimensions on clinically apparent THVT. The FSI study indicates that larger STJ and AAo diameters potentially favor thrombus formation by increased backflow rate and reduced wash-out efficiency of the sinus. The reported observations require clinical validation but could potentially help identifying patients at risk for THVT.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...