Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ophthalmologie ; 121(1): 43-52, 2024 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-37966616

RESUMO

BACKGROUND: The published results of trabeculotomy ab externo (TOT), as an outflow channel surgery in adults with open-angle glaucoma, are underrepresented in comparison with other pressure-lowering glaucoma procedures. OBJECTIVE: To determine the long-term pressure lowering effect and complications of TOT as a stand-alone procedure or in combination with phacoemulsification with intraocular lens implantation (PIT) as a primary pressure-lowering procedure in adult patients with forms of chronic open-angle glaucoma. METHOD: This was a retrospective analysis of 121 eyes of 106 patients wherby 90 eyes underwent TOT and 31 eyes underwent PIT. The follow-up period was 5 years. Follow-up was performed in the same center under standardized conditions. Preoperative as well as postoperative best-corrected distance visual acuity, intraocular pressure, pressure-lowering medication, and complications were recorded. For success criterion 1, the intraocular pressure was not allowed to exceed 17 mm Hg at any control. For success criterion 2, the intraocular pressure was allowed to be above 17 mm Hg at 1 control throughout the follow-up period. RESULTS: Preoperative intraocular pressure in the TOT group was 25.92 mm Hg (SD 6.58) and 26.32 mm Hg (SD 6.06) in the PIT group. The annual cumulative success rates with pressure-lowering medications for success criterion 1 were 92.8%, 82.5%, 70.5%, 52.7% and 26.1%. For success criterion 2 these were 97.9%; 94.9%, 93.2%, 91.3%, and 89%. We found no relevant difference in pressure reduction between TOT and PIT. Without pressure-lowering medications, success rates were significantly lower for both success criteria. No serious complications occurred. The most common postoperative complication was spontaneously resorbable hyphema. CONCLUSION: Performing TOT or PIT as a primary glaucoma procedure for chronic open-angle glaucoma in adults is reasonable, has a significant pressure-lowering effect and very low complication rate.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Trabeculectomia , Adulto , Humanos , Trabeculectomia/métodos , Glaucoma de Ângulo Aberto/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Glaucoma/complicações , Malha Trabecular/cirurgia
2.
Am J Ophthalmol ; 206: 256-263, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-30849343

RESUMO

PURPOSE: To analyze the dynamics of telemetrically measured intraocular pressure (IOP) during the first year after implantation of a Boston keratoprosthesis type I (BI-KPro) cornea and to compare agreement of telemetric IOP measurements with finger palpations. DESIGN: Prospective, open-label, multicenter, single-arm clinical trial. METHODS: In the ARGOS (NCT02945176) study, 12 individuals underwent implantation of an Eyemate-IO intraocular system. Follow-up after surgery took place 12 months later with 13 visits planned per patient. During BI-KPro surgery, an electromagnetic induction sensor ring enabling telemetric IOP data transfer to a hand-held reading device outside the eye was implanted into the ciliary sulcus with or without trans-scleral suture fixation. Comprehensive ophthalmic examinations and IOP assessments through the telemetric system were compared to IOP assessed by finger palpation by 2 experts. RESULTS: Preoperative IOP measured by Goldmann tonometry was 13.4 ± 6.2 mm Hg. Telemetric IOP peaked at 23.1 ± 16.5 mm Hg at the first postoperative day. On day 5, mean IOP was 16.0 ± 5.2 mm Hg and 20.95 ± 6.5 mm Hg after 6-12 months. IOP estimation by finger palpation was grouped in 4 categories: normal, A; soft/hypotonic, B; borderline, C; and hypertonic, D. Mean telemetric IOP was 18.2 ± 6.1 mm Hg in category A, 8.9 ± 2.8 mm Hg in B, 22.4 ± 4.9 mm Hg in C, and 34.3 ± 11.0 mm Hg in D. Differences in mean telemetric IOPs per category were statistically significant (P < .001). Daily IOP fluctuations and peaks could be identified. CONCLUSIONS: Telemetric IOP assessment seems to be able to identify postoperative IOP peaks and a longitudinal increase of IOP after BI-KPro surgery. IOP measurements using the telemetric Eyemate-IO sensor showed a satisfactory agreement with those of finger palpations by 2 experts.


Assuntos
Órgãos Artificiais/efeitos adversos , Doenças da Córnea/cirurgia , Glaucoma/diagnóstico , Pressão Intraocular/fisiologia , Procedimentos Cirúrgicos Oftalmológicos/efeitos adversos , Telemetria/métodos , Tonometria Ocular/métodos , Adolescente , Adulto , Doenças da Córnea/fisiopatologia , Feminino , Seguimentos , Glaucoma/etiologia , Glaucoma/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Prospectivos , Reprodutibilidade dos Testes , Acuidade Visual , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...