Rev Sci Instrum ; 86(4): 043307, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25933855

RESUMO

We have completed an ultra-high vacuum system for sensitive fast electron spectroscopy from cold cathodes in triode configuration under high electric fields E (<100 MV/m) and pulsed tunable laser illumination (3.5 ns, 10 Hz, hν = 0.5-5.9 eV, and 0.3-17 mJ). The cathodes are prepared and inserted under clean room conditions and can be precisely 3D-positioned, cooled or heated (77-400 K). Commissioning results with the upgraded system are presented. Field emission measurements with a W tip yielded an energy resolution of 14 meV at 4 eV pass energy and a precise determination of the emitter work function, size, and temperature. Photoemission spectroscopy of short electron bunches from a virgin and laser-ablated S-GaP crystal and quantum efficiency measurements revealed surface states, energy relaxation, and band structure effects. In conclusion, this novel system is ready now for the development and characterization of photo-induced field emission cathodes.

2.
Rev Sci Instrum ; 83(1): 013302, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22299940

RESUMO

We have constructed a new ultrahigh vacuum apparatus with a triode configuration for the systematic investigation of photo-induced field emission (PFE) from metallic or semiconducting cathodes. These are exposed to electric fields up to 400 MV∕m and laser irradiation by means of hole or mesh gates. Cathodes and gates are in situ exchangeable and adjustable with high precision to ensure a homogeneous extraction of electrons which are partially transmitted to the fixed electron spectrometer. Its hemispherical sector analyzer provides an energy resolution limit of 8 meV. The commissioning of the measurement system has been performed with a tungsten needle. Its temperature showed up in the high-energy tail of the electron spectrum, while its work function was derived from the spectral low-energy part combined with the integral current-voltage curve. First PFE measurements on B-doped Si-tip arrays yielded a small field emission current increase under green laser illumination. A shift and splitting of the energy spectra was observed which revealed different emission regimes as well as the photosensitivity of the cathode due to carrier excitation into the conduction band. For the full exploitation of the PFE system, a tunable laser over a wide eV-range is required.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...