Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Arch Dis Child ; 85(2): 166-71, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11466195

RESUMO

AIM: To examine early factors in bone mineral accretion in cystic fibrosis (CF). METHODS: In 22 prepubertal children with CF and mild lung disease, the relation between total body bone mineral density (BMD) and measures of body composition, biochemistry, lung function, and physical activity was studied. RESULTS: There was a non-significant mild reduction in mean total body BMD. No relation was found between BMD and anthropometric indices, fat free soft tissue, degree of lung disease, degree of fat malabsorption, dietary energy intake, or level of physical activity. Significant impairments in physical growth were apparent in this population and were found to correlate with degree of lung disease. CONCLUSION: A CF specific factor appears unlikely to be associated with the osteopenia commonly found in CF. Careful attention to general aspects of lifestyle and nutrition is recommended to maximise bone mineral accretion in this population.


Assuntos
Densidade Óssea , Fibrose Cística/fisiopatologia , Absorciometria de Fóton/métodos , Composição Corporal , Criança , Fibrose Cística/complicações , Ingestão de Energia , Metabolismo Energético/fisiologia , Exercício Físico/fisiologia , Feminino , Volume Expiratório Forçado/fisiologia , Transtornos do Crescimento/etiologia , Humanos , Masculino , Política Nutricional , Valores de Referência , Capacidade Vital/fisiologia
2.
Ann N Y Acad Sci ; 904: 55-62, 2000 May.
Artigo em Inglês | MEDLINE | ID: mdl-10865710

RESUMO

Liver cirrhosis is a condition in which overnutrition, edema, and undernutrition can coexist simultaneously, or successively, over a period of time, giving rise to alterations in body composition, as well as systemic and multiorgan manifestations. We undertook a cross-sectional study of body composition in 198 adult patients with liver cirrhosis (140 males, mean age 53.6, range 31-85 years; and 58 females, mean age 58.4, range 36-79 years). The patients had cirrhosis of differing etiology and different stages of severity. They were gathered from seven different hospital clinics in the city of Melbourne, Australia, but all the body composition measurements were performed in one body composition laboratory. A variety of body composition techniques were used to identify which commonly available ones could best assess both fat-free mass and fat mass relative to a criterion "gold-standard" method available in a specialist laboratory. A gold-standard fat-free mass (FFMGS) was defined as the sum of total body protein, measured by in vivo neutron activation analysis (IVNA), plus total body water, measured by D2O dilution, plus bone mineral content, measured by dual X-ray absorptiometry (DXA). A gold-standard fat mass (FATGS) was defined as the difference between body weight and FFMGS. "Usual" fat mass and fat-free mass were defined by different techniques including DXA, anthropometry (ANT), single-frequency bioelectrical impedance (SFBIA), multiple-frequency bioelectrical impedance spectroscopy (MFBIA), and whole body gamma counting (TBK). The FFMGS was overhydrated in both sexes, relative to the usual value of 0.73, but women were significantly overhydrated compared to men. Relative to the gold-standard deuterium oxide dilution method for measuring total body water, SFBIA slightly overestimated TBW, whereas MFBIA slightly underestimated TBW, with both methods having wide limits of agreement for any single estimate. In comparing FFM to FFMGS, only DXA showed a small negative bias, in both males and females, with modest limits of agreement for any single estimate. All other methods showed a large negative bias (ANT, SFBIA, and MFBIA) or a large positive bias (TBK) relative to FFMGS, with wide limits of agreement. In comparing FAT with the FATGS, only DXA showed a small positive bias, in both males and females, with modest limits of agreement for any single estimate. All other methods showed a large positive bias (ANT, SFBIA, and MFBIA) or a large negative bias (TBK) relative to FATGS, with wide limits of agreement. In cirrhosis, DXA is a good and widely available method to assess both fat mass and fat-free mass. However, it cannot give information about the quality of the FFM, particularly its water content. The bedside methods of anthropometry and bioelectrical impedance, both SFBIA and MFBIA, are poor methods of measuring body composition in patients with liver cirrhosis, whereas whole body gamma counting, although not widely available, also significantly differs from the gold-standard method of assessment of fat-free mass and fat mass in liver cirrhosis.


Assuntos
Absorciometria de Fóton/métodos , Tecido Adiposo/anatomia & histologia , Composição Corporal , Cirrose Hepática/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estatura , Água Corporal , Peso Corporal , Densidade Óssea , Óxido de Deutério , Impedância Elétrica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Ativação de Nêutrons , Proteínas/análise , Reprodutibilidade dos Testes , Caracteres Sexuais , Dobras Cutâneas
3.
Am J Clin Nutr ; 71(1): 36-43, 2000 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-10617944

RESUMO

BACKGROUND: Symptoms of cystic fibrosis (CF) may limit the utility of total body chlorine (TBCl) and total body potassium (TBK) measurements for assessing body fluid compartments of children. OBJECTIVE: This study assessed relations among independent measurements of TBCl, TBK, and total body water (TBW) in children with CF. DESIGN: We compared cross-sectional measurements of TBCl by in vivo neutron activation analysis, TBK by whole-body counting of (40)K, TBW by D(2)O dilution [TBW(D(2)O)], and TBW from TBCl and TBK [TBW(Cl + K)] in 19 prepubertal children (13 boys) aged 7.6-12.5 y who had mild symptoms of CF. Body-composition measurements were compared with data from previous studies of healthy children. RESULTS: Subjects with CF had deficits in TBCl, TBK, TBW, and body weight compared with control reference data (P < 0.05). The ratios (TBCl + TBK)/TBW and TBCl/TBK were not significantly different from control reference values, and plasma chlorine and potassium concentrations were within control reference ranges. The sum of TBCl and TBK correlated with TBW(D(2)O) (r(2) = 0.79, P < 0.001), and TBW(Cl + K) correlated with TBW(D(2)O) (r(2) = 0.78, P < 0.001). TBW(Cl + K) was similar to TBW(D(2)O) (mean +/- SEM: 19.0 +/- 0.5 compared with 19.4 +/- 0.5 L; NS). CONCLUSIONS: Prepubertal children with mild symptoms of CF can develop deficits in TBCl, TBK, and TBW that reflect chronic energy malnutrition. Mild symptoms of CF do not appear to affect normal relations among TBCl, TBK, and TBW. Measurements of TBCl and TBK may be used to assess body fluid compartments in these patients.


Assuntos
Composição Corporal , Compartimentos de Líquidos Corporais , Água Corporal/metabolismo , Cloro/metabolismo , Fibrose Cística/metabolismo , Potássio/metabolismo , Análise de Variância , Criança , Estudos Transversais , Feminino , Humanos , Masculino , Análise de Ativação de Nêutrons , Valores de Referência
5.
Australas Phys Eng Sci Med ; 19(4): 252-63, 1996 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9060212

RESUMO

The construction, calibration and evaluation of a prompt- gamma in vivo neutron activation analysis (IVNAA) facility for the simultaneous measurement of total body nitrogen (TBN) and chlorine (TBCl) in children is described. Subjects are irradiated unilaterally by a 0.2 GBq 252Cf neutron source from shoulder to mid thigh in both supine and prone positions. Prompt gamma-ray spectra are measured with two pairs of NaI(TI) crystals (each crystal: 10 cm x 10 cm x 15 cm) positioned on both sides of the subject. TBN and TBCl are estimated from the ratios of nitrogen-to-hydrogen (Nc/Hc) and chlorine-to-hydrogen (Clc/Hc) counts as determined from the measurement of 10.83 MeV, 8.57 MeV and 2.22 MeV prompt gamma-rays from the respective reactions 14N(n, gamma)15N, 36Cl(n, gamma)35Cl, and 1H(n, gamma)D. Nc/Hc and Clc/Hc are corrected for the effect of body width and thickness on background and gamma-ray attenuation. Total body hydrogen (TBH) is used as an internal standard which is independently determined using a four compartment model of body weight defined as the sum of total body water (TBW) measured by the D2O dilution technique, total body protein (TBPr) (i.e. 6.25 x TBN) measured by IVNAA, total body bone mineral (TBBM) measured by dual energy x-ray absorptiometry and total body fat (TBF) estimated as body weight less the sum of TBW, TBPr and TBBM. The effective dose equivalent to a small child is 0.25 mSv (Q = 20) per measurement scan. Repeated measurements of a child-size bottle phantom containing tissue-equivalent concentrations of nitrogen and chlorine yield respective intra- and inter-assay precision values of 2.8% (CV) and 2.3% for TBN measurements, and 7.9% and 10.0% for TBCl measurements. Similarly, intra- and inter-assay accuracy is determined to be respectively +0.1% +/- 1.0% (mean, 95% confidence interval) and +1.4% +/- 1.4% for TBN measurements, and +2.3% +/- 4.3% and +3.9% +/- 6.0% for TBCl measurements.


Assuntos
Composição Corporal , Cloro/análise , Instalações de Saúde , Análise de Ativação de Nêutrons , Nitrogênio/análise , Adulto , Fatores Etários , Antropometria , Calibragem , Criança , Estudos de Avaliação como Assunto , Humanos , Modelos Lineares , Imagens de Fantasmas , Reprodutibilidade dos Testes , Dosimetria Termoluminescente
6.
Eur J Clin Nutr ; 50(9): 607-16, 1996 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8880040

RESUMO

OBJECTIVE: To assess the usefulness of fat-free mass (FFM) as an index of total body protein (TBPr) status in continuous ambulatory peritoneal dialysis (CAPD) patients. DESIGN: TBPr was measured by in vivo neutron activation analysis (IVNAA) and expressed as a standardised protein index (PI). FFM was estimated by dual energy X-ray absorptiometry (DXA), whole body counting of total body potassium (TBK), and creatinine kinetics (CK), and expressed as a standardised FFM index (FFMI). FFM was also determined by a criterion method based on four compartment model (4CM) which is defined as the sum of total body water determined by D2O dilution, TBPr determined by IVNAA, bone mineral determined by DXA, and glycogen estimated to be 4.4% of TBPr. Each patient was measured within a four hour period by all methods. SETTING: Body Composition Laboratory, Monash Medical Centre. SUBJECTS: Six male and twelve female CAPD patients (33-77 years). RESULTS: FFMI assessed by DXA and by TBK agreed with measurements of PI on identifying the mean TBPr status of the CAPD group as significantly below a comparable normal reference population (mean Z score: PI = -1.01 (P < 0.05); FFMI by DXA = -0.50 (P < 0.05); FFMI by TBK = -1.24 (P < 0.05)). In contrast, FFMI assessed by CK did not reveal a significantly reduced TBPr status (mean Z score: -0.70 (NS)). Furthermore, significant linear correlations were noted between PI and FFMI estimated by DXA and by TBK (r = 0.57 (P < 0.05) vs r = 0.69 (P < 0.05)) however no significant correlation was observed between PI and FFMI estimated by CK (r = 0.36 (NS)). Moderate variation in FFM hydration did not compromise the ability of DXA, TBK or CK to differentiate between protein deleted, normal and enriched patients. Comparison of FFM estimates between the criterion method and either DXA, TBK or CK revealed no significant bias (+ 1.8 kg vs -2.0 kg vs +0.8 kg) and respective SEE values of 3.8 kg (8.3%), 5.9 kg (14.3%) and 9.6 kg (21.7%). CONCLUSION: The findings of this study indicate that FFM estimated by either DXA or the whole body counting of TBK is a useful index of TBPr status in CAPD patients. However, FFM assessed by CK does not appear to be an appropriate index of TBPr status in CAPD patients.


Assuntos
Tecido Adiposo , Índice de Massa Corporal , Diálise Peritoneal Ambulatorial Contínua , Proteínas , Absorciometria de Fóton , Adulto , Idoso , Antropometria , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Ativação de Nêutrons , Análise de Regressão
7.
Kidney Int ; 48(2): 563-9, 1995 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-7564127

RESUMO

This study compared the measurements of total body water (TBW) by 58% body weight (TBW58%), the Watson equation (TBWWV) and bioelectric impedance (TBWBIA) with the gold standard, Deuterium oxide (TBWD2O) dilution method in twenty continuous ambulatory peritoneal dialysis (CAPD) patients. TBW volumes were highest when calculated as TBW58% (42.6 +/- 9.4 liter) and lowest when calculated from TBWWV (34.6 +/- 6.8 liter). TBWBIA underestimated TBW when compared to TBWD2O, although the difference was not statistically significant (37.1 +/- 9.8 liter and 38.8 +/- 9.3 liter, respectively). In fact, TBWBIA correlated strongly with TBWD2O (r = 0.8, P < 0.0001). These discrepancies resulted in significant differences when Kt/V week-1 derived from the four methods were compared. To determine the effect of percent fat mass on the estimation of TBW by each method, we compared TBW and Kt/V week-1 derived from the four methods in nine CAPD patients who had normal percent fat mass (Non-Obese) and 11 CAPD patients who had greater than normal % fat mass (Obese). In the Non-Obese group, there was close correlation of TBWBIA, TBWWV and TBW58% when compared with TBWD2O (r = 0.93, P < 0.001, r = 0.89, P < 0.01 and R = 0.86, P < 0.01, respectively. Also, Kt/V week-1 derived from TBWBIA, TBWWV and TBW58% correlated strongly with Kt/V week-1 from TBWD2O (r = 0.93, P < 0.0005, r = 0.83, P < 0.01 and r = 0.8, P < 0.01, respectively).(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Modelos Biológicos , Diálise Peritoneal Ambulatorial Contínua , Ureia/metabolismo , Composição Corporal , Água Corporal , Peso Corporal , Óxido de Deutério , Impedância Elétrica , Humanos , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento
8.
Asia Pac J Clin Nutr ; 4(1): 47-50, 1995 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24394249

RESUMO

The feasibility of using prompt in vivo neutron activation Analysis (IVNAA) of nitrogen to measure the total body nitrogen (TBN) of newborn infants has been investigated by redesigning and recalibrating an existing IVNAA facility used for the measurement of TBN in adults. Repeated 1000 sec measurements of an infant phantom (4kg wt: 80g N) yielded an average measured value that is within 0.2± 1.8% (1xSD) of the actual value and a precision of 7.9% (CV) for a single measurement. Preliminary investigations indicate that the whole body radiation dose is no greater than 1 mSv (Q=20) for a 1000 s irradiation. It is proposed, and in part demonstrated, that measurement precision can be reduced to ≒5% by (i) using a graphite neutron reflector positioned over the infant to increase the in vivo thermal neutron flux, and (ii) doubling the number of NaI(TI) detectors.

9.
Asia Pac J Clin Nutr ; 4(1): 161-5, 1995 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24394274

RESUMO

The principles of quality control (QC) are not new; they have always been with mankind. At the most fundamental level QC can be defined as a state of mind in which we continually strive to analyse what we are doing in order to produce a 'product' which our peers will judge to be 'better' . Paradoxically, this simple concept is expressed in many different ways within the multi-disciplinary team that makes up a body composition laboratory and very careful discussion is needed to ensure uniformity of technique and results. The situation is made even more difficult by the large range of equipment and techniques that are now available for the measurement of body composition. It is necessary to have a detailed understanding of the equipment and techniques and to have good communication within the group of workers. Good communication is essential to ensure that all members of the group have a clear understanding of the relevant guidelines and principles of QC and measurements, and to ensure that they are applied consistently throughout all the work of the laboratory. A detailed understanding of the equipment is necessary in order to define and implement simple tests that will monitor the most sensitive or troublesome features without imposing an undue burden upon the operator. There is a need for such tests to be automated as much as possible and, in general, there is a need for a more professional approach to the analysis of error and its propagation throughout an experiment. Inter comparisons of results between centres is a logical, but generally difficult requirement and some of the problems that arise would be simplified if equipment designs were more standardized. Finally, all these requirements need to be achieved within an environment that is continually changing with respect to the aims of the laboratory and the funding bodies.

10.
Australas Phys Eng Sci Med ; 14(1): 1-7, 1991 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-2029237

RESUMO

A technique has been developed for measuring the spatial sensitivity of a prompt gamma in vivo neutron activation analysis facility as used for determining total body nitrogen (i.e. protein). A water filled perspex phantom was used to simulate a patient. Relative spatial sensitivity of the system was measured at various positions in the tank by observing the prompt gamma rays from thermal neutron capture in the 35Cl of a carbon tetrachloride sample contained in a small glass phial.


Assuntos
Análise de Ativação de Nêutrons/instrumentação , Espectrometria gama/instrumentação , Nêutrons Rápidos , Humanos , Nitrogênio/análise , Proteínas/análise
12.
Phys Med Biol ; 34(1): 53-9, 1989 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-2928378

RESUMO

A major problem in the measurement of nitrogen in the body by in vivo neutron activation analysis is the size of the background. Investigations show that random summing of gamma rays in the range 4-7 MeV is a major contributor. By direct comparison, 252Cf is shown to be a better neutron source than Pu-Be in this regard. Data are presented on the contribution to the background of water and chloride in the body.


Assuntos
Nitrogênio/análise , Radiometria/métodos , Berílio , Califórnio , Humanos , Análise de Ativação de Nêutrons/métodos , Plutônio , Radioisótopos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...