Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
2.
Ann Surg Oncol ; 30(9): 5472-5485, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37340200

RESUMO

BACKGROUND: Involved lateral lymph nodes (LLNs) have been associated with increased local recurrence (LR) and ipsi-lateral LR (LLR) rates. However, consensus regarding the indication and type of surgical treatment for suspicious LLNs is lacking. This study evaluated the surgical treatment of LLNs in an untrained setting at a national level. METHODS: Patients who underwent additional LLN surgery were selected from a national cross-sectional cohort study regarding patients undergoing rectal cancer surgery in 69 Dutch hospitals in 2016. LLN surgery consisted of either 'node-picking' (the removal of an individual LLN) or 'partial regional node dissection' (PRND; an incomplete resection of the LLN area). For all patients with primarily enlarged (≥7 mm) LLNs, those undergoing rectal surgery with an additional LLN procedure were compared to those  undergoing only rectal resection. RESULTS: Out of 3057 patients, 64 underwent additional LLN surgery, with 4-year LR and LLR rates of 26% and 15%, respectively. Forty-eight patients (75%) had enlarged LLNs, with corresponding recurrence rates of 26% and 19%, respectively. Node-picking (n = 40) resulted in a 20% 4-year LLR, and a 14% LLR after PRND (n = 8; p = 0.677). Multivariable analysis of 158 patients with enlarged LLNs undergoing additional LLN surgery (n = 48) or rectal resection alone (n = 110) showed no significant association of LLN surgery with 4-year LR or LLR, but suggested higher recurrence risks after LLN surgery (LR: hazard ratio [HR] 1.5, 95% confidence interval [CI] 0.7-3.2, p = 0.264; LLR: HR 1.9, 95% CI 0.2-2.5, p = 0.874). CONCLUSION: Evaluation of Dutch practice in 2016 revealed that approximately one-third of patients with primarily enlarged LLNs underwent surgical treatment, mostly consisting of node-picking. Recurrence rates were not significantly affected by LLN surgery, but did suggest worse outcomes. Outcomes of LLN surgery after adequate training requires further research.


Assuntos
Excisão de Linfonodo , Neoplasias Retais , Humanos , Excisão de Linfonodo/métodos , Estudos Transversais , Linfonodos/cirurgia , Linfonodos/patologia , Neoplasias Retais/patologia , Reto/patologia , Estudos Retrospectivos , Recidiva Local de Neoplasia/cirurgia , Recidiva Local de Neoplasia/patologia , Estadiamento de Neoplasias
3.
Eur Radiol ; 32(9): 6526-6535, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35420303

RESUMO

OBJECTIVES: To determine the value of a deep learning masked (DLM) auto-fixed volume of interest (VOI) segmentation method as an alternative to manual segmentation for radiomics-based diagnosis of clinically significant (CS) prostate cancer (PCa) on biparametric magnetic resonance imaging (bpMRI). MATERIALS AND METHODS: This study included a retrospective multi-center dataset of 524 PCa lesions (of which 204 are CS PCa) on bpMRI. All lesions were both semi-automatically segmented with a DLM auto-fixed VOI method (averaging < 10 s per lesion) and manually segmented by an expert uroradiologist (averaging 5 min per lesion). The DLM auto-fixed VOI method uses a spherical VOI (with its center at the location of the lowest apparent diffusion coefficient of the prostate lesion as indicated with a single mouse click) from which non-prostate voxels are removed using a deep learning-based prostate segmentation algorithm. Thirteen different DLM auto-fixed VOI diameters (ranging from 6 to 30 mm) were explored. Extracted radiomics data were split into training and test sets (4:1 ratio). Performance was assessed with receiver operating characteristic (ROC) analysis. RESULTS: In the test set, the area under the ROC curve (AUCs) of the DLM auto-fixed VOI method with a VOI diameter of 18 mm (0.76 [95% CI: 0.66-0.85]) was significantly higher (p = 0.0198) than that of the manual segmentation method (0.62 [95% CI: 0.52-0.73]). CONCLUSIONS: A DLM auto-fixed VOI segmentation can provide a potentially more accurate radiomics diagnosis of CS PCa than expert manual segmentation while also reducing expert time investment by more than 97%. KEY POINTS: • Compared to traditional expert-based segmentation, a deep learning mask (DLM) auto-fixed VOI placement is more accurate at detecting CS PCa. • Compared to traditional expert-based segmentation, a DLM auto-fixed VOI placement is faster and can result in a 97% time reduction. • Applying deep learning to an auto-fixed VOI radiomics approach can be valuable.


Assuntos
Aprendizado Profundo , Neoplasias da Próstata , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Estudos Retrospectivos
4.
PLoS One ; 8(2): e58053, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23460924

RESUMO

BACKGROUND: The objectives of this study were to evaluate the influence of iterative reconstruction (IR) on pulmonary nodule volumetry with chest computed tomography (CT). METHODS: Twenty patients (12 women and 8 men, mean age 61.9, range 32-87) underwent evaluation of pulmonary nodules with a 64-slice CT-scanner. Data were reconstructed using filtered back projection (FBP) and IR (Philips Healthcare, iDose(4)-levels 2, 4 and 6) at similar radiation dose. Volumetric nodule measurements were performed with semi-automatic software on thin slice reconstructions. Only solid pulmonary nodules were measured, no additional selection criteria were used for the nature of nodules. For intra-observer and inter-observer variability, measurements were performed once by one observer and twice by another observer. Algorithms were compared using the concordance correlation-coefficient (pc) and Friedman-test, and post-hoc analysis with the Wilcoxon-signed ranks-test with Bonferroni-correction (significance-level p<0.017). RESULTS: Seventy-eight nodules were present including 56 small nodules (volume<200 mm(3), diameter<8 mm) and 22 large nodules (volume≥200 mm(3), diameter≥8 mm). No significant differences in measured pulmonary nodule volumes between FBP, iDose(4)-levels 2, 4 and 6 were found in both small nodules and large nodules. FBP and iDose(4)-levels 2, 4 and 6 were correlated with pc-values of 0.98 or higher for both small and large nodules. Pc-values of intra-observer and inter-observer variability were 0.98 or higher. CONCLUSIONS: Measurements of solid pulmonary nodule volume measured with standard-FBP were comparable with IR, regardless of the IR-level and no significant differences between measured volumes of both small and large solid nodules were found.


Assuntos
Intensificação de Imagem Radiográfica , Nódulo Pulmonar Solitário/diagnóstico por imagem , Nódulo Pulmonar Solitário/patologia , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Medidas de Volume Pulmonar , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Nódulo Pulmonar Solitário/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...