Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ned Tijdschr Geneeskd ; 161: D2480, 2018.
Artigo em Holandês | MEDLINE | ID: mdl-29328018

RESUMO

OBJECTIVE: To investigate how internal medicine residents allocate their time during a hospital dayshift on the wards. DESIGN: Prospective observational cohort study (time and motion study). METHODS: Data were collected from 36 internal medicine residents working at the Internal Medicine Department of the Academic Medical Centre in Amsterdam, the Netherlands. Trained observers monitored 22 residents using a newly developed smartphone-application, registering their dayshift activities (meetings and education, direct patient contact, administrative tasks, lunch/break, other) and location (workstation, conference room, ward and patient rooms, other). Data of 14 residents on work-related activities during after-hours in the hospital and at home were collected through a questionnaire. RESULTS: Residents were observed for a total of 210 hours. The average workday encompassed 9.5 hours. During this dayshift, residents spent an average of 38% of their time on administrative tasks, and 37% on interprofessional consultation and educational activities. Direct patient/family contact accounted for 13% of the workday. After the evening handover at 5 pm, on average another 80 minutes of work was performed in the hospital, of which 73 minutes (91%) entailed administration. At home, they spent on average another 52 minutes on patient care related work, of which 51 minutes (98%) consisted of administration. CONCLUSION: The internal medicine residents on the ward spend most of their dayshift on indirect patient care. This comprises mostly computer-based administrative tasks. After the dayshift, many residents continue to work in their own time to finish remaining paperwork. Study limitations are the limited total number of monitored residents, the total observation time and possible self-report bias.


Assuntos
Medicina Interna/estatística & dados numéricos , Internato e Residência/estatística & dados numéricos , Médicos/estatística & dados numéricos , Jornada de Trabalho em Turnos/estatística & dados numéricos , Centros Médicos Acadêmicos , Estudos de Coortes , Feminino , Hospitais , Humanos , Masculino , Países Baixos , Estudos Prospectivos , Inquéritos e Questionários , Estudos de Tempo e Movimento
3.
Eur Radiol ; 27(6): 2451-2462, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27709280

RESUMO

OBJECTIVES: To determine whether there is a difference in frequency and clinical relevance of incidental findings detected by total-body computed tomography scanning (TBCT) compared to those by the standard work-up (STWU) with selective computed tomography (CT) scanning. METHODS: Trauma patients from five trauma centres were randomized between April 2011 and January 2014 to TBCT imaging or STWU consisting of conventional imaging with selective CT scanning. Incidental findings were divided into three categories: 1) major finding, may cause mortality; 2) moderate finding, may cause morbidity; and 3) minor finding, hardly relevant. Generalized estimating equations were applied to assess differences in incidental findings. RESULTS: In total, 1083 patients were enrolled, of which 541 patients (49.9 %) were randomized for TBCT and 542 patients (50.1 %) for STWU. Major findings were detected in 23 patients (4.3 %) in the TBCT group compared to 9 patients (1.7 %) in the STWU group (adjusted rate ratio 2.851; 95%CI 1.337-6.077; p < 0.007). Findings of moderate relevance were detected in 120 patients (22.2 %) in the TBCT group compared to 86 patients (15.9 %) in the STWU group (adjusted rate ratio 1.421; 95%CI 1.088-1.854; p < 0.010). CONCLUSIONS: Compared to selective CT scanning, more patients with clinically relevant incidental findings can be expected by TBCT scanning. KEY POINTS: • Total-body CT scanning in trauma results in 1.5 times more incidental findings. • Evaluation by TBCT in trauma results in more patients with incidental findings. • In every category of clinical relevance, TBCT detects more incidental findings.


Assuntos
Ferimentos e Lesões/diagnóstico por imagem , Adulto , Feminino , Humanos , Achados Incidentais , Masculino , Pessoa de Meia-Idade , Encaminhamento e Consulta , Tomografia Computadorizada por Raios X/métodos , Centros de Traumatologia , Imagem Corporal Total/métodos
4.
Acta Paediatr ; 93(9): 1221-7, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15384888

RESUMO

AIM: In the present, prospective study, the relation between the levels of midazolam, its two active metabolites--1-hydroxy-midazolam (OH-midazolam) and 1-hydroxy-midazolam-glucuronide (glu-midazolam)--and the aEEG were examined. PATIENTS AND METHODS: Fifteen full-term neonates with seizures due to hypoxic-ischaemic encephalopathy admitted to our NICU were included. Midazolam (loading dose 0.05 mg/kg in 10 min, maintenance dose 0.15 mg/kg/h) was used as an add-on anti-convulsant after phenobarbital and lidocaine because of continuing seizures. Amplitude-integrated EEG background pattern was scored at the start of midazolam and at the time of blood sampling as continuous normal voltage (CNV), discontinuous normal voltage (DNV), burst suppression (BS), continuous low voltage (CLV) or flat trace (FT). Serum levels of midazolam, OH-midazolam and glu-midazolam were measured at least 8 h after the start with HPLC. RESULTS: In 11/15 patients, seizures were abolished with the addition of midazolam. In the remaining patients, seizure frequency was reduced in one and unchanged in three. Amplitude-integrated EEG background pattern at the start of midazolam was CNV in two, DNV in six, BS in five and CLV in two. Moderate, temporary suppression of the aEEG background pattern lasting less than 2 h was seen in four neonates. Amplitude-integrated EEG at midazolam sampling was CNV in two, DNV in seven, CLV in two and FT in four. Serum levels of midazolam ranged from 0.10 to 1.76 mg/l, OH-midazolam from 0.05 to 0.28 mg/l and glu-midazolam from 0.85 to 4.36 mg/l. CONCLUSIONS: A brief and moderate suppression of the aEEG background pattern immediately after midazolam was seen in four neonates for less than 2 h. Suppression at a later time point, i.e. after more than 8 h of midazolam infusion, was demonstrated almost exclusively in neonates with a poor background pattern, and therefore these patterns appear to be determined mainly by the severity of hypoxic-ischaemic encephalopathy.


Assuntos
Anticonvulsivantes/sangue , Anticonvulsivantes/farmacologia , Asfixia Neonatal/fisiopatologia , Eletroencefalografia/efeitos dos fármacos , Midazolam/sangue , Midazolam/farmacologia , Anticonvulsivantes/uso terapêutico , Asfixia Neonatal/sangue , Asfixia Neonatal/complicações , Encéfalo/efeitos dos fármacos , Encéfalo/fisiopatologia , Idade Gestacional , Humanos , Recém-Nascido , Midazolam/uso terapêutico , Estudos Prospectivos , Convulsões/sangue , Convulsões/tratamento farmacológico , Convulsões/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...