Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Magn Reson Med ; 9(1): 105-12, 1989 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-2709988

RESUMO

Fears have been voiced that excessive tissue heating could occur in the event that first, a surface coil is placed with its axis parallel to the transmitting rf field leading to a maximal coupling of the two coils and second, the decoupling circuit of the surface coil breaks down. To avoid an rf coupling of the transmitting body coil to the receive-only surface coil, conventionally applied surface coils are equipped with an active electronic rf decoupling circuit. In extensive worst-case experiments on phantoms we have shown that no tissue heating occurs for surface coils which are equipped with semiconductor varicap diodes for tuning and matching. These coils should be safe for patient applications even if the decoupling circuit fails. Surface coils equipped with mechanically variable capacitors are generally passively decoupled. To simulate the worst-case situation phantom experiments were performed in which a surface coil of this type having no passive decoupling circuit was coupled to the transmitter coil by its geometric position. Theoretical calculations, in agreement with the experimental results achieved during a 15-min measurement in a 1.5-T MRI whole-body imager, show that a significant rf power deposition in the tissue underneath the coil wire occurs, leading typically to a local specific absorption rate of 24 W/kg and a local temperature rise of 5.2 degrees C.


Assuntos
Temperatura Alta , Imageamento por Ressonância Magnética/efeitos adversos , Condutividade Elétrica , Eletrônica Médica , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Magnetismo , Modelos Biológicos , Modelos Estruturais , Segurança
2.
AJR Am J Roentgenol ; 151(1): 107-12, 1988 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-3259791

RESUMO

Twenty-four patients with carcinoma of the urinary bladder were examined with MR imaging by using both a conventional body coil and a newly designed wraparound double surface coil. All patients had T1- and two patients had T2-weighted pulse sequences with both coils. Because of the long examination times, T2-weighted sequences in all other patients were obtained by using the double surface coil only. Nine patients underwent radical cystectomy, while the other patients had deep transurethral tumor resection and a clinical follow-up of at least 1.5 years. The results of imaging with the surface coil showed a twofold improvement of spatial resolution compared with the images obtained with the body coil. The RF field homogeneity was excellent, and the field of view was sufficiently large to achieve a complete study of the pelvis and the lower abdomen in one sequence. For the T1-weighted images, the higher spatial resolution of the double surface coil resulted in a significant (p less than .10) improvement in tumor staging. The accuracies of double-surface-coil and body-coil imaging were 79% and 54%, respectively. Double-surface-coil imaging appears to provide better MR images of the urinary bladder than body-coil imaging does, resulting in more accurate staging of tumors on T1-weighted pulse sequences.


Assuntos
Carcinoma de Células de Transição/diagnóstico , Neoplasias da Bexiga Urinária/diagnóstico , Carcinoma de Células de Transição/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Neoplasias da Bexiga Urinária/patologia
4.
Magn Reson Med ; 3(2): 270-81, 1986 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-3713491

RESUMO

The construction and application of eight different MRI surface coils is described. The coils consist of an anatomically shaped copper wire loop as an antenna and a printed circuit board containing electronic components for tuning and matching. The electronic device for tuning and matching is interchangeable between the various coils. Surface coils for signal detection yield images with high signal-to-noise ratio in comparison to the usual saddle-shaped head or body coils. The sensitivity of a surface coil decreases with increasing distance between the coil and the object of interest and therefore the coils are constructed to fit the anatomical structure under examination as well as possible. The application of dedicated surface coils for superficial structures in the body extends the possibilities of the MRI system. Photographs of the coils positioned on the body and MR images of volunteers and patients are shown.


Assuntos
Espectroscopia de Ressonância Magnética/instrumentação , Animais , Cobre , Eletrônica Médica/instrumentação , Humanos , Politetrafluoretileno , Ratos
5.
Radiology ; 157(2): 449-52, 1985 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-4048454

RESUMO

We obtained magnetic resonance images with good sensitivity and radio frequency (RF) uniformity using separate transmitter and receiver coils. The excitation, namely, the rotation of the magnetization vector into a plane perpendicular to the magnetic field, was done by applying a homogeneous RF magnetic field produced by a large saddle-shaped coil. Surface coils were used for detection only. Because two coils that operated on the same resonance frequency were used, a coupling problem developed. This problem, which involved inhomogeneity of the RF magnetic field caused by the large current induced in the surface coil during excitation, could only be solved by minimizing the mutual inductance or maximizing the impedance of the surface coil resonance circuit during excitation. We were able to solve this problem using an electronic detuning method.


Assuntos
Espectroscopia de Ressonância Magnética/métodos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...