Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Magn Reson Imaging ; 22(3): 400-5, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16106357

RESUMO

To evaluate the feasibility of MR colonography (MRC) with air using two-dimensional (2D) T1-weighted fast spin-echo (T1wFSE) in patients scheduled for conventional colonoscopy (CC) after classic bowel preparation, and assess the ability of the technique to detect colonic lesions. The distention was sufficient for diagnosis, and the technique provided adequate delineation of the wall in the majority of segments. Residual fluid obscured the wall in different segments, especially in the ascending and descending colon (supine position) and in the cecum, transverse, and sigmoid colon (prone position). These findings were consistent with CT colonography. MRC visualized three lesions, missed one lesion >10 mm, visualized none of four lesions <5 mm, and yielded one false-positive lesion (5-10 mm). Missed lesions can be due to inconsistency in the slice positions between consecutive breath-holds, which is inherent to the multishot technique. Residual fluid may have obscured the smaller lesions. The shortcomings of the technique are limited coverage and signal drop-off at the borders of the field of view (FOV). Before multishot 2D T1wFSE colonography can become a valid screening method, improved patient preparation and a more practical technique are needed.


Assuntos
Colo/anatomia & histologia , Colonoscopia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Colonografia Tomográfica Computadorizada , Neoplasias Colorretais/diagnóstico , Reações Falso-Positivas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
2.
J Magn Reson Imaging ; 22(3): 368-72, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16106364

RESUMO

PURPOSE: To evaluate the influence of Gd-DTPA on cartilage T2 mapping using turbo-mixed (tMIX) imaging, and to show the possible usefulness of the tMIX technique for simultaneously acquiring T1 and T2 information in cartilage. MATERIALS AND METHODS: Twenty volunteers underwent MRI of the knee using the tMIX sequence before and after gadolinium administration. T1 and T2 maps were calculated. The mean T1 was determined on the pre- and postcontrast T1 maps. T2 relaxation values before and after gadolinium administration were statistically analyzed. RESULTS: The obtained relaxation values are in correspondence with previously published data. The mean T1 before gadolinium administration was 449 msec +/- 34.2 msec (SD), and after gadolinium administration it was 357 msec +/- 55.8 msec (SD). The postcontrast T1 relaxation range was 221.5-572.8 msec. The mean T2 of the precontrast T2 maps was 34.2 msec +/- 3.1 msec (SD), and the mean T2 of the postcontrast T2 maps was 32.5 msec +/- 3.1 msec (SD). These are statistically significant different values. A correction for the postcontrast T2 values, using a back-calculation algorithm, yielded a 98% correlation with the precontrast T2 values. CONCLUSION: The absolute difference of pre- and postcontrast T2 is very small and is ruled out using the back-calculation algorithm. Combined T1-T2 tMIX cartilage mapping is a valuable alternative for separate T1 and T2 cartilage mapping.


Assuntos
Cartilagem Articular/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Feminino , Fêmur , Gadolínio DTPA , Humanos , Articulação do Joelho/anatomia & histologia , Masculino , Tíbia
3.
Radiology ; 233(2): 609-14, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15375229

RESUMO

The feasibility of a high-spatial-resolution technique for mapping T1 and T2 in articular cartilage in the human knee was evaluated. The technique, turbo mixed magnetic resonance (MR) imaging, is based on a pulse sequence in which inversion-recovery and spin-echo measurements are interleaved. The sequence was first validated in a phantom experiment in which T1 and T2 values obtained with an accepted spectroscopic technique were correlated with those obtained by using a clinical magnetic resonance imager with the turbo mixed technique. T2 maps were obtained with turbo mixed imaging in 25 volunteers (17 men, eight women; mean age, 30.8 years; range, 23-45 years). A high correlation (r = 0.99) was found between T1 and T2 values obtained at spectroscopy and those obtained at turbo mixed imaging. Relative differences in the range of cartilage relaxation times between the two techniques were less than 20%. Turbo mixed imaging in human volunteers showed T2 cartilage relaxation times that corresponded with previously published data. Turbo mixed imaging, thus, is feasible for T2 mapping of cartilage.


Assuntos
Cartilagem Articular , Articulação do Joelho , Imageamento por Ressonância Magnética/métodos , Adulto , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...