Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Infect Dis ; 24(1): 660, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38956504

RESUMO

INTRODUCTION: Tuberculosis is a global health problem that causes 1. 4 million deaths every year. It has been estimated that sputum smear-negative diagnosis but culture-positive pulmonary TB diagnosis contribute to 12.6% of pulmonary TB transmission. TB diagnosis by smear microscopy smear has a minimum detection limit (LOD) of 5,000 to 10,000 bacilli per milliliter (CFU/ml) of sputum result in missed cases and false positives. However, GeneXpert technology, with a LOD of 131-250 CFU/ml in sputum samples and its implementation is believe to facilitate early detection TB and drug-resistant TB case. Since 2013, Ghana health Service (GHS) introduce GeneXpert MTB/RIF diagnostic in all regional hospitals in Ghana, however no assessment of performance between microscopy and GeneXpert TB diagnosis cross the health facilities has been reported. The study compared the results of routine diagnoses of TB by microscopy and Xpert MTB from 2016 to 2020 at the Cape Coast Teaching Hospital (CCTH). METHODS: The study compared routine microscopic and GeneXpert TB diagnosis results at the Cape Coast Teaching Hospital (CCTH) from 2016 to 2020 retrospectively. Briefly, sputum specimens were collected into 20 mL sterile screw-capped containers for each case of suspected TB infection and processed within 24 h. The samples were decontaminated using the NALC-NaOH method with the final NaOH concentration of 1%. The supernatants were discarded after the centrifuge and the remaining pellets dissolved in 1-1.5 ml of phosphate buffer saline (PBS) and used for diagnosis. A fixed smears were Ziehl-Neelsen acid-fast stain and observed under microscope and the remainings were used for GeneXpert MTB/RIF diagnosis. The data were analyze using GraphPad Prism. RESULTS: 50.11% (48.48-51.38%) were females with an odd ratio (95% CI) of 1.004 (0.944-1.069) more likely to report to the TB clinic for suspected TB diagnosis. The smear-positive cases for the first sputum were 6.6% (5.98-7.25%), and the second sputum was 6.07% (5.45-6.73%). The Xpert MTB-RIF diagnosis detected 2.93% (10/341) (1.42-5.33%) in the first and 5.44% (16/294) (3.14-8.69%) in the second smear-negative TB samples. The prevalence of Xpert MTB-RIF across smear positive showed that males had 56.87% (178/313) and 56.15% (137/244) and females had 43.13% (135/313) and 43.85% (107/244) for the first and second sputum. Also, false negative smears were 0.18% (10/5607) for smear 1 and 0.31% (16/5126) for smear 2. CONCLUSION: In conclusion, the study highlights the higher sensitivity of the GeneXpert assay compared to traditional smear microscopy for detecting MTB. The GeneXpert assay identified 10 and 16 positive MTB from smear 1 and smear 2 samples which were microscopic negative.


Assuntos
Hospitais de Ensino , Microscopia , Mycobacterium tuberculosis , Escarro , Tuberculose Pulmonar , Humanos , Mycobacterium tuberculosis/isolamento & purificação , Mycobacterium tuberculosis/genética , Estudos Retrospectivos , Escarro/microbiologia , Gana/epidemiologia , Feminino , Adulto , Masculino , Microscopia/métodos , Pessoa de Meia-Idade , Tuberculose Pulmonar/diagnóstico , Tuberculose Pulmonar/microbiologia , Adulto Jovem , Adolescente , Sensibilidade e Especificidade , Idoso , Técnicas de Diagnóstico Molecular/métodos , Criança , Pré-Escolar
2.
Int J Public Health ; 67: 1604721, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36589476

RESUMO

Objectives: We aimed to understand the information architecture and degree of integration of mortality surveillance systems in Ghana and Peru. Methods: We conducted a cross-sectional study using a combination of document review and unstructured interviews to describe and analyse the sub-systems collecting mortality data. Results: We identified 18 and 16 information subsystems with independent databases capturing death events in Peru and Ghana respectively. The mortality information architecture was highly fragmented with a multiplicity of unconnected data silos and with formal and informal data collection systems. Conclusion: Reliable and timely information about who dies where and from what underlying cause is essential to reporting progress on Sustainable Development Goals, ensuring policies are responding to population health dynamics, and understanding the impact of threats and events like the COVID-19 pandemic. Integrating systems hosted in different parts of government remains a challenge for countries and limits the ability of statistics systems to produce accurate and timely information. Our study exposes multiple opportunities to improve the design of mortality surveillance systems by integrating existing subsystems currently operating in silos.


Assuntos
COVID-19 , Estatísticas Vitais , Humanos , Gana/epidemiologia , Peru/epidemiologia , Estudos Transversais , Pandemias
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...