Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Analyst ; 147(6): 1199-1212, 2022 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-35199110

RESUMO

Methods that increase sensitivity are a constant topic in research. To increase the sensitivity for high-performance liquid chromatography (HPLC) a continuous injection method with a sinusoidal analyte concentration profile was developed. The sinusoidal analyte concentration profile is obtained by a sinusoidal variation of the relative volume contents between two solvent reservoirs, one containing a pure solvent and the other an analyte stock solution prepared with the same solvent. Discrete Fourier transformation enables the analyte-specific phase angle shift to be calculated from the chromatograms. The proposed method is established and evaluated for size exclusion chromatography (SEC). Accordingly, the phase angle shift is used for molecular weight determination by establishing a molecular weight calibration using different narrowly distributed polystyrene (PS) calibration standards. In a comparison with conventional SEC, the Signal-to-Noise ratio (S/N), normalized to the square root of the time of the evaluated data set, increases by a factor of approximately 50.


Assuntos
Cromatografia Líquida , Cromatografia em Gel , Cromatografia Líquida de Alta Pressão/métodos , Peso Molecular , Solventes/química
2.
Macromol Rapid Commun ; 42(21): e2100448, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34528318

RESUMO

This article presents a fast, straightforward synthesis approach to polymerize alternating multiblock copolymers, ultra-high molecular weight (UHMW) (homo)polymers as well as precursors for complex macromolecular topologies such as comb or barbwire architectures. The one-pot synthesis strategy proposed in this work is based on anionic polymerization via a bifunctional initiator and the subsequent linking of macro dianions with a bifunctional linker, additionally overcoming the limitations associated with the monomer reactivity. Thus, the synthetic route guarantees the repeating size of polymer blocks and an equal distribution of functional groups in precursors for complex topologies. Dianions of polystyrene (PS), polyisoprene-b-polystyrene-b-polyisoprene, and poly-2-vinylpyridine-b-polystyrene-b-poly-2-vinylpyridine are linked with α , α ' -dibromo-para-xylene to UHMW and multiblock copolymers. Multiblock copolymers with on average up to 50 well-defined alternating A and B blocks are accessible within 15 min.


Assuntos
Polímeros , Ânions , Substâncias Macromoleculares , Peso Molecular , Polimerização
3.
Macromol Rapid Commun ; 40(18): e1900228, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31298758

RESUMO

Online chemically sensitive detectors for size exclusion chromatography (SEC) through coupled setups based on infrared (IR) (or NMR) spectrometers present new possibilities through unprecedented levels of polymer detail with respect to molecular weight and chemical composition. Herein, a new external cavity quantum cascade laser (EC-QCL) mid-IR spectrometer as a chemically sensitive online detector for SEC is custom-designed, built, and tested. This unique spectrometer features multiple broadly tunable EC-QCL sources, which can be operated in continuous wave and pulsed mode, accompanied with balanced liquid nitrogen cooled mercury cadmium telluride (MCT) detectors and a new custom-built transmission flow cell. Automated data analysis is done with a self-written MATLAB code. The limit of detection (LOD) is measured online, coupled with SEC chromatography, where on average, one carbonyl functionality in 530 000 g mol-1 at chromatographic conditions for SEC could be detected. It is possible to detect 0.46 µg (LOD) PMMA, which is approximately a factor of 30 lower than that reported for SEC-Fourier transform infrared.


Assuntos
Cromatografia em Gel/métodos , Lasers Semicondutores , Polímeros/química , Compostos de Cádmio/química , Compostos de Mercúrio/química , Peso Molecular , Polímeros/análise , Espectrofotometria Infravermelho/métodos
4.
Anal Bioanal Chem ; 410(18): 4259-4273, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29845323

RESUMO

Amphiphilic hyaluronic acid (HA), synthesised by modifying HA to varying extents with acrylate groups, was successfully separated according to degree of substitution (DS) using solvent gradient high performance liquid chromatography (HPLC). Two HPLC methods based on the amphiphilic structure of the HA were developed. In the first approach, normal phase gradient HPLC was explored, and separation was based on the interactions of HA's polar hydroxyl groups with a polar cyano stationary phase. In the second approach, separation was based on the interaction of the hydrophobic acrylate moieties with a non-polar C8 stationary phase (reversed phase gradient HPLC). The separation was optimised by using an electrolyte in the sample solvent to suppress non-covalent interactions and improve the selectivity of the developed method. The photolytic stability of the modified and unmodified HA was also investigated in order to optimise the sample preparation procedure. Furthermore, an alternative method to NMR spectroscopy was developed for determining the DS of HA. Graphical abstract ᅟ.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Cromatografia de Fase Reversa/métodos , Ácido Hialurônico/isolamento & purificação , Ácido Hialurônico/química , Interações Hidrofóbicas e Hidrofílicas , Fotólise , Espectroscopia de Prótons por Ressonância Magnética , Solventes/química , Espectroscopia de Infravermelho com Transformada de Fourier
5.
Macromol Rapid Commun ; 39(7): e1700766, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29399906

RESUMO

A state-of-the-art, medium-resolution 1 H-NMR spectrometer (62 MHz) is used as a chemically sensitive online detector for size-exclusion chromatography of polymers such as polymethylmethacrylate (PMMA) and polystyrene (PS). The method uses protonated eluents and works at typical chromatographic conditions with trace amounts of analytes (<0.5 g L-1 after separation). Strong solvent suppression, e.g., by a factor of 500, is achieved by means of T1 -filtering and mathematical subtraction methods. Substantial improvements are made with respect to previous work in terms of the sensitivity (signal-to-noise ratio up to 130:1, PMMA OCH3 ) and selectivity (peak width, full width half maximum (FWHM) 4 Hz on-flow). Typical homopolymers and a blend are investigated to deformulate their composition along the dimensions of molecular weight and NMR chemical shift. These results validate this new hyphenated chromatography method, which can greatly facilitate analysis and is much more effective than previously published results.


Assuntos
Cromatografia em Gel , Ressonância Magnética Nuclear Biomolecular , Polimetil Metacrilato , Poliestirenos , Cromatografia em Gel/instrumentação , Cromatografia em Gel/métodos , Ressonância Magnética Nuclear Biomolecular/instrumentação , Ressonância Magnética Nuclear Biomolecular/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...