1.
Foot Ankle Int ; 34(4): 486-90, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23399887

RESUMO

BACKGROUND: Tendon transfers are commonly used for correction of pathology or deformity of the foot and ankle. Bioabsorbable implants have been developed as an alternative to metal interference screws. The purpose of this study was to document complications following tendon transfers of the foot and ankle using bioabsorbable poly-L-lactide interference screws. METHODS: A retrospective chart review was used to identify patients in whom either of the 2 senior authors had performed a tendon transfer of the foot and ankle using a bioabsorbable interference screw between 1999 and 2005. A minimum of 6 months of follow-up was required for inclusion in the study. In all, 31 patients were identified who met the inclusion criteria with an average follow-up of 75 weeks. All screws were made of poly-L-lactide (PLLA). RESULTS: Complications were identified in 12 (39%) of patients. All of the complications reported were known complications of the tendon transfer procedure itself, and were not directly related to the bioabsorbable screw. CONCLUSIONS: Based on these early results, PLLA implants appear safe and effective for tendon transfers of the foot and ankle. However, until long-term outcomes are available, judicious use of these implants is recommended.


Assuntos
Tornozelo/cirurgia , Pé/cirurgia , Tendinopatia/cirurgia , Transferência Tendinosa/efeitos adversos , Implantes Absorvíveis , Tendão do Calcâneo/lesões , Adulto , Idoso , Artrite/cirurgia , Parafusos Ósseos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Poliésteres , Ruptura/cirurgia , Transferência Tendinosa/instrumentação
2.
Foot Ankle Int ; 27(4): 251-5, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16624214

RESUMO

BACKGROUND: For a fracture classification to be useful it must provide prognostic significance, interobserver reliability, and intraobserver reproducibility. Most studies have found reliability and reproducibility to be poor for fracture classification schemes. The purpose of this study was to evaluate the interobserver and intraobserver reliability of the Sanders and Crosby-Fitzgibbons classification systems, two commonly used methods for classifying intra-articular calcaneal fractures. METHODS: Twenty-five CT scans of intra-articular calcaneal fractures occurring at one trauma center were reviewed. The CT images were presented to eight observers (two orthopaedic surgery chief residents, two foot and ankle fellows, two fellowship-trained orthopaedic trauma surgeons, and two fellowship-trained foot and ankle surgeons) on two separate occasions 8 weeks apart. On each viewing, observers were asked to classify the fractures according to both the Sanders and Crosby-Fitzgibbons systems. Interobserver reliability and intraobserver reproducibility were assessed with computer-generated kappa statistics (SAS software; SAS Institute Inc., Cary, North Carolina). RESULTS: Total unanimity (eight of eight observers assigned the same fracture classification) was achieved only 24% (six of 25) of the time with the Sanders system and 36% (nine of 25) of the time with the Crosby-Fitzgibbons scheme. Interobserver reliability for the Sanders classification method reached a moderate (kappa = 0.48, 0.50) level of agreement, when the subclasses were included. The agreement level increased but remained in the moderate (kappa = 0.55, 0.55) range when the subclasses were excluded. Interobserver agreement reached a substantial (kappa = 0.63, 0.63) level with the Crosby-Fitzgibbons system. Intraobserver reproducibility was better for both schemes. The Sanders system with subclasses included reached moderate (kappa = 0.57) agreement, while ignoring the subclasses brought agreement into the substantial (kappa = 0.77) range. The overall intraobserver agreement was substantial (kappa = 0.74) for the Crosby-Fitzgibbons system. CONCLUSIONS: Although intraobserver kappa values reached substantial levels and the Crosby-Fitzgibbons system generally showed greater agreement, we were unable to demonstrate excellent interobserver or intraobserver reliability with either classification scheme. While a system with perfect agreement would be impossible, our results indicate that these classifications lack the reproducibility to be considered ideal.


Assuntos
Traumatismos do Tornozelo/classificação , Calcâneo/lesões , Fraturas Ósseas/classificação , Traumatismos do Tornozelo/epidemiologia , Estudos de Coortes , Feminino , Fraturas Ósseas/epidemiologia , Humanos , Escala de Gravidade do Ferimento , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade