Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pan Afr Med J ; 32: 161, 2019.
Artigo em Francês | MEDLINE | ID: mdl-31303930

RESUMO

Serum protein electrophoresis (SPE) is a routine analysis in the daily practice of a medical biology laboratory. This study aimed to analyze the different electrophoretic profiles seen in our current practice. We conducted a cross-sectional study of 410 serum samples collected during the routine analyses in the Laboratory of Biochemistry at the University Hospital Mohammed VI in Oujda. Serum protein electrophoresis was performed using automated instrument CAPILLARYS 2 FLEX-PIERCING, SEBIA. 241 sera from women and 169 sera from men were collected. Patients were aged between 1-91 years, with an average age of 49 years; 19.5% of SPEs were normal, hypoalbuminemia was found in 34% of cases, chronic inflammatory syndrome in 19.5% of cases, nephrotic syndrome in 2% of cases, 5.8% of our patients had betagamma block, hypogammaglobulinemia was found in 8.5% of cases and 29 monoclonal peaks were noted, bisalbuminemia was found in 2 patients. Out of 410 collections: 92 immunofixations were performed, of whom 23 were positive (showing monoclonal gammopathy). This study highlights the variability in prescribing serum protein electrophoresis as well as the importance of clinical data for a better interpretation.


Assuntos
Eletroforese das Proteínas Sanguíneas/métodos , Hipoalbuminemia/diagnóstico , Inflamação/diagnóstico , Paraproteinemias/diagnóstico , Adolescente , Adulto , Agamaglobulinemia/diagnóstico , Agamaglobulinemia/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Estudos Transversais , Feminino , Hospitais Universitários , Humanos , Hipoalbuminemia/epidemiologia , Lactente , Inflamação/epidemiologia , Masculino , Pessoa de Meia-Idade , Síndrome Nefrótica/diagnóstico , Síndrome Nefrótica/epidemiologia , Paraproteinemias/epidemiologia , Adulto Jovem
2.
Pract Lab Med ; 15: e00121, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31011608

RESUMO

BACKGROUND: The aim of this work is to present the results of a comparative study between the ALT assay on Integra 400 plus Roche Diagnostic versus Architect ci8200 of Abbott Diagnostic. METHODS: A total of 200 patients hospitalized in the various departments of the university hospital Mohammed VI of Oujda were prospectively tested on two systems: Abbott Architect ci8200 and Roche Integra 400 plus. Both analyzers use the spectrophotometric technique by coupling the transamination reaction to the oxidation-reduction reaction at NAD. The agreement of the results between the different techniques was evaluated using the Bland-Altman difference diagram and the Passing-Bablok and Deming regression line. RESULTS: There was a high concordance between the two assays: the equation of the Passing-Bablok line is YArchitect â€‹= â€‹-0,5625 â€‹+ â€‹0,9917 XIntegra with a correlation coefficient r2 = 0.999. The Bland-Altman diagram shows that the mean bias between the two methods is of the order of 1.1 IU/L and the difference between the ALT measurements by Architect and Integra is in the range of -1.4 to 3.6. CONCLUSION: Our study shows a high correlation of the ALT assay results between the architect ci8200 and Integra 400 plus.

3.
Ann Biol Clin (Paris) ; 77(2): 187-190, 2019 04 01.
Artigo em Francês | MEDLINE | ID: mdl-30907376

RESUMO

Primary plasma cell leukemia (PPCL) is an aggressive and rare variant of multiple myeloma (MM), with frequent extramedullary involvement, mainly liver and splenic lesions. Pleuropulmonary involvement has rarely been described in the literature. We report a case of primary plasma cell leukemia in a 46-year-old patient, whose first symptom was pleural effusion with mediastinal adenopathies simulating a pleural localization of a lymphomatous process. However, blood smear examination, electrophoresis as well as immunofixation of plasma proteins and immuno-histochemistry have helped to guide the diagnosis. Pleurisy is a rare mode of revelation of plasma cell leukemia and is a factor of poor prognosis.


Assuntos
Leucemia Plasmocitária/diagnóstico , Neoplasias Pleurais/diagnóstico , Pleurisia/diagnóstico , Evolução Fatal , Feminino , Humanos , Leucemia Plasmocitária/complicações , Leucemia Plasmocitária/patologia , Pessoa de Meia-Idade , Marrocos , Derrame Pleural/diagnóstico , Derrame Pleural/etiologia , Derrame Pleural/patologia , Neoplasias Pleurais/complicações , Neoplasias Pleurais/patologia , Pleurisia/etiologia , Pleurisia/patologia , Radiografia Torácica
4.
EJIFCC ; 30(1): 82-87, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30881277

RESUMO

Gaucher disease (GD) is a lysosomal storage disease. It corresponds to a congenital deficit in ß-glucocerebrosidase. This pathology should be considered in the presence of unexplained splenomegaly, with or without signs of haemorrhage, skeletal manifestations or hepatomegaly. The diagnosis is based on the measurement of the ß-glucocerebrosidase activity but the preanalytical process should be respected in order to avoid the under-diagnosis of this disorder and the delay of its management. We report two cases of Gaucher disease collected at Mohammed VI University Hospital and Al Farabi regional hospital in Oujda. We have emphasized the need for a reference center for overload diseases.

5.
EJIFCC ; 30(1): 88-94, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30881278

RESUMO

Non-secretory myeloma (NSM) is a rare form of myeloma. It is defined as monoclonal plasmocytic proliferation of the bone marrow with the same clinical and radiological manifestations of myeloma. However, plasma cells are unable to secrete immunoglobulin (serum and urinary electrophoresis are negative and free light chain measurement is unquantifiable). This variant of multiple myeloma (MM) usually poses a diagnostic challenge to the biologist and clinician. We report a rare case of non-secretory myeloma in a 76-year-old patient who was diagnosed at the Mohammed V University Hospital Center in Oujda, Morocco.

6.
Ann Biol Clin (Paris) ; 76(1): 61-67, 2018 01 01.
Artigo em Francês | MEDLINE | ID: mdl-29243659

RESUMO

Parathormone (PTH) is the main hormone of phosphocalcic homeostasis. It is synthesized and secreted by the parathyroid glands. PTH has become a routine test in the medical biology laboratory. However, its measurement presents analytical difficulties with the various marketed kits. The aim of this work is to present the results of a comparative study between the PTH measurment on Abbott architect ci8200 and on Roche's Cobas e411 automaton. It is a prospective study carried out for 252 hospitalized patients in the various departments of the University Hospital Center Mohammed VI of Oujda. The "intact" PTH tests were performed on two automata: Abbott Architect ci8200 and Roche Cobas e411. The first uses chemiluminescent microparticle immunoassay. The second uses electrochemiluminiscence sandwich enzyme immunoassay. The agreement of the results between the different techniques was evaluated using the Bland-Altman difference diagram and the Passing-Bablok and Deming regression line (MedCalc software version 14.8.1.0®). By analyzing the diagram of Bland-Altman, we note that the average bias between both methods is of the order of 193.9 pg/mL. As for the equation of the right of Passing-Bablok, it is: Y(Architect) = 3.11 X (Cobas) - 12.26. In conclusion, our study shows a great discrepancy between the results of the PTH assay on the Architect ci8200 versus the Cobas e411, hence the biologist's indisputable role in the control and evaluation of the kits marketed through the various validation tests.


Assuntos
Análise Química do Sangue/instrumentação , Análise Química do Sangue/métodos , Hormônio Paratireóideo/sangue , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Coleta de Amostras Sanguíneas/normas , Criança , Pré-Escolar , Estudos Transversais , Feminino , Humanos , Imunoensaio/instrumentação , Imunoensaio/métodos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Hormônio Paratireóideo/análise , Radioimunoensaio/instrumentação , Radioimunoensaio/métodos , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...