Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Cardiothorac Surg ; 34(3): 583-8; discussion 588, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18667331

RESUMO

OBJECTIVE: The performance of the Ross procedure in the case of geometric mismatch between pulmonary autograft and a bicuspid aortic root has not yet been fully evaluated. To prevent geometrically caused autograft dysfunction, a modification of the surgical technique is necessary. METHODS: Between January 1996 and January 2007, 50 patients (33 male, 17 female; mean age 50+/-14 years; range 13-63 years) underwent replacement of a diseased bicuspid aortic valve (stenosis in 14 cases; insufficiency in 21; combined disease in 15) with a Ross procedure. The pulmonary autograft was inserted partially in supra-annular position to correct the geometric mismatch between the deeper base of the non-coronary sinus and the right/left coronary sinus. In 24 of these patients, additional tailoring of the non-coronary sinus was necessary. In eight patients the non-coronary sinus was covered with a glutaraldehyde treated autologous pericardial patch to prevent pseudoaneurysm formation. Patients were followed up 1, 2, 5 and 10 years postoperatively. RESULTS: There were no early or late deaths. There were six reoperations. One patient was reoperated because of persistent severe aortic valve insufficiency 9 months postoperatively. Three patients were reoperated for formation of subannular pseudoaneurysm, 6, 9 and 30 months postoperatively. One patient was reoperated for closure of a paravalvular dehiscence. Another patient was reoperated 1 year postoperatively because of a severe pulmonary stenosis due to excessive calcification of the bioprosthesis. Echocardiographic follow-up of the remaining patients showed no evidence of residual or recurrent pulmonary autograft regurgitation or progression of aortic root dilatation. CONCLUSION: Autograft replacement of the bicuspid aortic valve is challenging, as the geometric mismatch has to be adjusted. Valve dysfunction is avoided by a supra-annular implantation technique, but pseudoaneurysm formation at the base of the non-coronary sinus is a worrying aspect. Patch reinforcement may solve this issue.


Assuntos
Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Valva Pulmonar/transplante , Adolescente , Adulto , Valva Aórtica/anormalidades , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Bioprótese , Feminino , Seguimentos , Próteses Valvulares Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reoperação/métodos , Resultado do Tratamento , Ultrassonografia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...