Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diabetes Care ; 43(1): 44-52, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31484666

RESUMO

OBJECTIVE: The HypoCOMPaSS study was designed to test the hypothesis that successful avoidance of biochemical hypoglycemia without compromising overall glycemic control would restore sufficient hypoglycemia awareness to prevent recurrent severe hypoglycemia in the majority of participants with established type 1 diabetes. Before starting the study, we planned to investigate associations between baseline characteristics and recurrent severe hypoglycemia over 2 years' follow-up. RESEARCH DESIGN AND METHODS: A total of 96 adults with type 1 diabetes and impaired awareness of hypoglycemia participated in a 24-week 2 × 2 factorial randomized controlled trial comparing insulin delivery and glucose monitoring modalities, with the goal of rigorous biochemical hypoglycemia avoidance. The analysis included 71 participants who had experienced severe hypoglycemia in the 12-month prestudy with confirmed absence (complete responder) or presence (incomplete responder) of severe hypoglycemia over 24 months' follow-up. RESULTS: There were 43 (61%) complete responders and 28 (39%) incomplete responders experiencing mean ± SD 1.5 ± 1.0 severe hypoglycemia events/person-year. At 24 months, incomplete responders spent no more time with glucose ≤3 mmol/L (1.4 ± 2.1% vs. 3.0 ± 4.8% for complete responders; P = 0.26), with lower total daily insulin dose (0.45 vs. 0.58 units/24 h; P = 0.01) and greater impairment of hypoglycemia awareness (Clarke score: 3.8 ± 2.2 vs. 2.0 ± 1.9; P = 0.01). Baseline severe hypoglycemia rate (16.9 ± 16.3 vs. 6.4 ± 10.8 events/person-year; P = 0.002) and fear of hypoglycemia were higher in incomplete responders. Peripheral neuropathy was more prevalent in incomplete responders (11 [39%] vs. 2 [4.7%]; P < 0.001) with a trend toward increased autonomic neuropathy. CONCLUSIONS: Recurrent severe hypoglycemia was associated with higher preintervention severe hypoglycemia rate, fear of hypoglycemia, and concomitant neuropathy.


Assuntos
Conscientização , Transtornos Cognitivos/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemia/induzido quimicamente , Hipoglicemia/diagnóstico , Insulina/efeitos adversos , Adolescente , Adulto , Idoso , Glicemia/análise , Glicemia/efeitos dos fármacos , Glicemia/metabolismo , Automonitorização da Glicemia , Transtornos Cognitivos/complicações , Transtornos Cognitivos/diagnóstico , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/diagnóstico , Feminino , Humanos , Hipoglicemia/psicologia , Insulina/administração & dosagem , Sistemas de Infusão de Insulina , Masculino , Pessoa de Meia-Idade , Prognóstico , Recidiva , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento , Adulto Jovem
2.
Diabetes Technol Ther ; 21(11): 619-626, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31335201

RESUMO

Background: In the HypoCOMPaSS trial, adults with long-standing type 1 diabetes and problematic hypoglycemia were randomized to compare insulin pump (continuous subcutaneous insulin infusion; CSII) with multiple daily injections (MDI) and real-time continuous glucose monitoring (RT-CGM) with conventional self-monitoring of blood glucose (SMBG). Our aim was to investigate participants' satisfaction with these technologies at 6-month randomized, controlled trial (RCT) endpoint and at 2-year follow-up. Methods: Participants completed the Insulin Treatment Satisfaction Questionnaire subscales "device delivery" and "hypoglycemia control"; and Glucose Monitoring Experience Questionnaire, assessing "convenience", "effectiveness", "intrusiveness", and "total satisfaction." We assessed change over time and between-group differences by insulin and monitoring modalities. Results: Participants (N = 96) were 64% women, aged 49 ± 12 years, with a diabetes duration of 29 ± 12 years. At 6 months, participants reported improvements compared with baseline (all P < 0.001) in satisfaction with insulin "delivery device" (r = 0.39) and "hypoglycemia control" (r = 0.52), and trends toward significance in perceived "effectiveness" (r = 0.42) and "intrusiveness" (r = 0.27) of monitoring device (but not "convenience", P = 0.139). All improvements were sustained at 2 years. At 6 months, the only difference between arms was that greater satisfaction with insulin "delivery device" was reported in the CSII group compared with MDI (P < 0.001, r = 0.40). No between-group differences were observed at 2 years. Conclusions: Overall, significant improvements in participant satisfaction with diabetes technologies were observed over the 6-month RCT, in all domains except "convenience," and maintained at 2 years. Although HypoCOMPaSS demonstrated noninferiority of SMBG versus CGM, and MDI versus CSII in terms of biomedical outcomes, detailed assessments confirm that participants' satisfaction with delivery device was greater in those allocated to CSII than MDI.


Assuntos
Glicemia/efeitos dos fármacos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/efeitos dos fármacos , Hipoglicemia/prevenção & controle , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina/estatística & dados numéricos , Insulina/administração & dosagem , Satisfação do Paciente/estatística & dados numéricos , Adulto , Idoso , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/sangue , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Adulto Jovem
3.
Diabetes Care ; 41(8): 1600-1607, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29661916

RESUMO

OBJECTIVE: Severe hypoglycemia is a feared complication of type 1 diabetes; yet, few trials have targeted prevention using optimized self-management (educational, therapeutic, and technological support). We aimed to investigate whether improved awareness and reduced severe hypoglycemia, achieved during an intensive randomized clinical trial (RCT), were sustained after return to routine care. RESEARCH DESIGN AND METHODS: Ninety-six adults with type 1 diabetes (29 ± 12 years' duration) and impaired awareness of hypoglycemia at five U.K. tertiary referral diabetes centers were recruited into a 24-week 2 × 2 factorial RCT (HypoCOMPaSS). Participants were randomized to pump (continuous subcutaneous insulin infusion [CSII]) or multiple daily injections (MDIs) and real-time continuous glucose monitoring (RT-CGM) or self-monitoring of blood glucose (SMBG), with equal education/attention to all groups. At 24 weeks, participants returned to routine care with follow-up until 24 months, including free choice of MDI/CSII; RT-CGM vs. SMBG comparison continued to 24 months. Primary outcome was mean difference (baseline to 24 months [between groups]) in hypoglycemia awareness. RESULTS: Improvement in hypoglycemia awareness was sustained (Gold score at baseline 5.1 ± 1.1 vs. 24 months 3.7 ± 1.9; P < 0.0001). Severe hypoglycemia rate was reduced from 8.9 ± 12.8 episodes/person-year over the 12 months prestudy to 0.4 ± 0.8 over 24 months (P < 0.0001). HbA1c improved (baseline 8.2 ± 3.2% [66 ± 12 mmol/mol] vs. 24 months 7.7 ± 3.1% [61 ± 10 mmol/mol]; P = 0.003). Improvement in treatment satisfaction and reduced fear of hypoglycemia were sustained. There were no significant differences between interventions at 24 months. CONCLUSIONS: Optimized insulin replacement and glucose monitoring underpinned by hypoglycemia-focused structured education should be provided to all with type 1 diabetes complicated by impaired awareness of hypoglycemia.


Assuntos
Conscientização , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemia/induzido quimicamente , Hipoglicemia/epidemiologia , Insulina/efeitos adversos , Adulto , Glicemia/efeitos dos fármacos , Glicemia/metabolismo , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/epidemiologia , Feminino , Seguimentos , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemia/sangue , Hipoglicemia/psicologia , Injeções , Insulina/administração & dosagem , Sistemas de Infusão de Insulina , Masculino , Pessoa de Meia-Idade , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...