Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Orthop J Sports Med ; 8(7): 2325967120938039, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32782906

RESUMO

BACKGROUND: All-inside anterior cruciate ligament reconstruction (ACLR) is an emerging technique used to treat ACL injuries. The all-inside technique uses a 4-stranded graft made from a single tendon that is looped on itself. The 4 strands of the graft must be secured to each other to become a closed-loop structure. Various suture configurations exist to secure the graft to adjustable loop devices, and there is a lack of data to support one technique over another. In addition to the primary sutures used to fasten the graft together, accessory sutures can be tied over the button as secondary fixation. PURPOSE: To evaluate biomechanical properties of 4-stranded grafts prepared in 5 different configurations. STUDY DESIGN: Controlled laboratory study. METHODS: Porcine flexor tendons (N = 25) were prepared in 5 different configurations (n = 5 tendons per group): simple-interrupted sutures (unsecured fixation), side-to-side fixation with and without secondary fixation, and end-to-end fixation with and without secondary fixation. The grafts were put through the same mechanical testing protocol (cyclic loading, pull to failure) to measure average load at graft failure, average displacement at failure, average stiffness, and average elongation rate. Differences between graft preparation techniques were investigated using 1-way analyses of variance (ANOVAs) with post hoc t tests (P < .05). RESULTS: Significant 1-way ANOVAs for each biomechanical property were found. Unsecured fixation was the weakest graft preparation with the lowest stiffness (167 ± 12 N/mm), lowest ultimate failure load (637 ± 99 N), and highest elongation rate (0.0033 ± 0.0007 mm/s). End-to-end fixation without secondary fixation showed the highest ultimate failure load (846 ± 26 N), highest stiffness (212 ± 10 N/mm), and lowest rate of elongation (0.0025 ± 0.0001 mm/s). End-to-end fixation, both with and without secondary fixation, as well as side-to-side fixation with secondary fixation showed significantly higher ultimate failure loads than grafts with unsecured fixation. End-to-end fixation performed better than side-to-side fixation; however, for most variables, the difference was not statistically significant. Secondary fixation did not provide significant improvement. CONCLUSION: The all-inside ACL graft with simple-interrupted sutures is biomechanically inferior to a graft that has its free ends secured to the adjustable tibial loop. Adding secondary fixation to the tibial button does not significantly change the biomechanical properties. Further clinical studies are required to determine whether these findings translate into differences in clinical outcome. CLINICAL RELEVANCE: All-inside ACLR is gaining popularity in hamstring ACL reconstructive techniques. These results provide surgeons with guidance on the best graft preparation method when using a single quadrupled hamstring tendon graft.

2.
Front Surg ; 6: 63, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31803752

RESUMO

Talar avascular necrosis (AVN) can result in bone collapse with subsequent ankle and subtalar osteoarthritis ending in significant pain and disability. Custom talar body prostheses have been implanted with good results but these are difficult to design, costly and require extensive planning. In the past few years, we have investigated the feasibility of a universal talar replacement prosthesis through multiple studies. This report documents that development and the results from the first patient to receive a universal talar replacement prosthesis. A patient with bilateral talar AVN with collapse had implantation of two universal talar prostheses with final evaluations at 34 months (right) and 12 months (left) post-implantation using visual analog scale, range of motion, SF-36 questionnaire, and personal reflection. The patient had decreased pain, increase range of motion, improvement (or no change) on all domains of the SF-36 and expressed great appreciation for having the procedures done. This report demonstrates the effectiveness and feasibility of a universal talar prosthesis. Continued development of this type of implant can decrease costs, improve access, and provide an acceptable alternative when a custom prosthesis is not possible.

3.
World J Orthop ; 7(12): 793-800, 2016 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-28032031

RESUMO

Metatarsal fractures are one of the most common injuries of the foot. There has been conflicting literature on management of fifth metatarsal fractures due to inconsistency with respect to classification of these fractures. This article provides a thorough review of fifth metatarsal fractures with examination of relevant literature to describe the management of fifth metatarsal fractures especially the proximal fracture. A description of nonoperative and operative management for fifth metatarsal fractures according to anatomical region is provided.

4.
Infect Immun ; 82(7): 2902-12, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24778110

RESUMO

In the present study, we have investigated the evolution and impact on virulence of a 350-kb genomic duplication present in the most recently evolved members of the Mycobacterium tuberculosis East Asian lineage. In a mouse model of infection, comparing HN878 subclones HN878-27 (no duplication) and HN878-45 (with the 350-kb duplication) revealed that the latter is impaired for in vivo growth during the initial 3 weeks of infection. Furthermore, the median survival time of mice infected with isolate HN878-45 is significantly longer (77 days) than that of mice infected with HN878-27. Whole-genome sequencing of both isolates failed to reveal any mutational events other than the duplication that could account for such a substantial difference in virulence. Although we and others had previously speculated that the 350-kb duplication arose in response to some form of host-applied selective pressure (P. Domenech, G. S. Kolly, L. Leon-Solis, A. Fallow, M. B. Reed, J. Bacteriol. 192: 4562-4570, 2010, and B. Weiner, J. Gomez, T. C. Victor, R. M. Warren, A. Sloutsky, B. B. Plikaytis, J. E. Posey, P. D. van Helden, N. C. Gey van Pittius, M. Koehrsen, P. Sisk, C. Stolte, J. White, S. Gagneux, B. Birren, D. Hung, M. Murray, J. Galagan, PLoS One 7: e26038, 2012), here we show that this large chromosomal amplification event is very rapidly selected within standard in vitro broth cultures in a range of isolates. Indeed, subclones harboring the duplication were detectable after just five rounds of in vitro passage. In contrast, the duplication appears to be highly unstable in vivo and is negatively selected during the later stages of infection in mice. We believe that the rapid in vitro evolution of M. tuberculosis is an underappreciated aspect of its biology that is often ignored, despite the fact that it has the potential to confound the data and conclusions arising from comparative studies of isolates at both the genotypic and phenotypic levels.


Assuntos
Mycobacterium tuberculosis/genética , Mycobacterium tuberculosis/patogenicidade , Tuberculose/microbiologia , Animais , Feminino , Duplicação Gênica , Regulação Bacteriana da Expressão Gênica , Camundongos , Mycobacterium tuberculosis/classificação , Virulência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...