Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-33230542

RESUMO

The objective of this work is to investigate the possibility to set a national diagnostic reference levels (nDRLs) for diagnostic and screening mammography in Serbia based on local practice and available resources. This study included all types of mammography systems that are currently used in Serbia, namely screen-film mammography (SFM), computed radiography (CR) and full-field digital mammography (FFDM). The nDRLs are provided in terms of mean glandular dose (MGD) for different breast thicknesses simulated by polymethyl methacrylate (PMMA) phantom. For each breast thickness, MGD was calculated for the X-ray tube output, using clinically used exposure parameters. DRLs were chosen as the 75th percentile of MGD distribution for 20-, 40-, 45-, 60- and 70-mm phantom thicknesses. For SFM units proposed nDRL values are 0.7, 2.1, 2.7, 4.6 and 6.8 mGy; for CR units proposed nDRL values are 0.7, 1.8, 2.4, 4.5 and 5.6 mGy; and corresponding values for FFDM units are 0.8, 1.7, 2, 2. and 3.2 mGy for 20-, 40-, 45-, 60- and 70-mm PMMA thickness, respectively.

2.
Radiat Prot Dosimetry ; 170(1-4): 279-83, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26464526

RESUMO

The objective of this work is to assess the occupational dose in interventional cardiology in a large hospital in Belgrade, Serbia. A double-dosimetry method was applied for the estimation of whole-body dose, using thermoluminescent dosemeters, calibrated in terms of the personal dose equivalent Hp(10). Besides the double-dosimetry method, eye dose was also estimated by means of measuring ambient dose equivalent, H*(10), and doses per procedure were reported. Doses were assessed for 13 physicians, 6 nurses and 10 radiographers, for 2 consequent years. The maximum annual effective dose assessed was 4.3, 2.1 and 1.3 mSv for physicians, nurses and radiographers, respectively. The maximum doses recorded by the dosemeter worn at the collar level (over the apron) were 16.8, 11.9 and 4.5 mSv, respectively. This value was used for the eye lens dose assessment. Estimated doses are in accordance with or higher than annual dose limits for the occupational exposure.


Assuntos
Cardiologia/métodos , Cristalino/efeitos da radiação , Exposição Ocupacional/análise , Radiologia Intervencionista/métodos , Radiometria/métodos , Algoritmos , Calibragem , Fluoroscopia , Humanos , Enfermeiras e Enfermeiros , Exposição Ocupacional/prevenção & controle , Médicos , Roupa de Proteção , Doses de Radiação , Exposição à Radiação , Proteção Radiológica/métodos , Proteção Radiológica/normas , Radiografia , Sérvia , Recursos Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...