Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Lab Med ; 27(1): 123-38, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17416306

RESUMO

Multichannel volume dispensing devices, such as automated liquid handlers, are widely used in drug discovery assays and other high-throughput screening processes. The performance of these systems is heavily based on the ability to deliver proper volumes of specific reagents. Discussed herein is the recent research on broadening existing methods for accurately assessing liquid-handler performance when dispensing complex or nonaqueous reagents. Accurate and reliable adjustment of liquid-handler protocols for varied reagent types could have far-reaching adoption in all scientific communities.


Assuntos
Dimetil Sulfóxido/química , Microquímica/instrumentação , Microquímica/normas , Calibragem , Técnicas de Química Combinatória/instrumentação , Técnicas de Química Combinatória/normas , Análise de Falha de Equipamento , Indicadores e Reagentes , Agulhas , Controle de Qualidade , Reprodutibilidade dos Testes , Manejo de Espécimes/instrumentação , Manejo de Espécimes/métodos , Água/química
2.
Appl Opt ; 43(1): 70-8, 2004 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-14714646

RESUMO

A technique to determine the angular orientation of a molecular assembly bound to the surface of a planar optical waveguide of arbitrary structure is described. The approach is based on measuring the absorption dichroic ratio by using the waveguide evanescent fields with orthogonal polarizations (TE, TM) and the same mode order to probe two molecular assemblies, (i) a reference sample composed of an isotropic orientation distribution of dipoles and (ii) a sample of interest. The isotropic sample is used to characterize the waveguide structure, which then allows the orientation parameters of a molecular assembly under investigation to be determined from a measured dichroic ratio. The method developed here is particularly important for applications in gradient-index and multilayer planar waveguide platforms because in those cases the extension of previously reported approaches would require a full experimental characterization of the guiding structure, which would be problematic and may yield inaccurate results.

3.
Anal Chem ; 75(5): 1080-8, 2003 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-12641226

RESUMO

A single-mode, electroactive waveguiding platform capable of measuring spectroelectrochemical responses of surface-adsorbed redox-active molecules over a broad spectral bandwidth has been created. This new planar waveguide spectrometer is a combination of the previously developed electroactive integrated optical waveguide (EA-IOW; Dunphy, D. R.; Mendes, S. B.; Saavedra, S. S.; Armstrong, N. R. Anal. Chem. 1997, 69, 3086-3094) with a recently reported simplified approach to broadband coupling (Bradshaw, J. T.; Mendes, S. B.; Saavedra, S. S. Anal. Chem. 2002, 74, 1751-1759). With the use of a commercially available prism as an incoupling element, the EA-IOW can now guide visible light from at least 500 to 700 nm, improving upon its previously demonstrated monochromatic nature. Coupling profiles of various laser lines along with transmission spectra of narrow band-pass filters at various potentials are used to demonstrate the optical characteristics of this broadband EA-IOW and to compare its response to that of a conventional transmission instrument. Assessment of spectral resolution, performed by measuring the fwhm of various laser lines, ranges from 0.6 to 0.8. To demonstrate the capabilities of this technology, we show the acquisition of absorbance spectra of two different adsorbates, cytochrome c and ferrocenedicarboxylic acid, as a function of applied potential. Subtleties in the redox chemistries of adsorbed molecules, which were difficult to monitor with a monochromatic waveguide, are readily apparent when using the broadband coupling scheme.


Assuntos
Eletroquímica/instrumentação , Indicadores e Reagentes , Oxirredução , Proteínas/química , Proteínas/isolamento & purificação , Propriedades de Superfície
4.
Anal Chem ; 74(8): 1751-9, 2002 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-11985305

RESUMO

A new generation waveguide spectrometer with broadband coupling capabilities has been developed. As opposed to previous devices, this attenuated total reflection (ATR) spectrometer is much simpler in design, is more chemically robust, and transmits light down to at least 400 nm. The attenuated total reflection element consists of a single-mode, planar integrated optical waveguide fabricated by dip-coating a approximately 300 nm thick, sol-gel composite layer on a glass substrate. A commercially available prism is used as the incoupler with an integral holographic diffraction grating acting as the dispersive outcoupling element. The transmission of narrow band-pass filters was used to compare the response of the waveguide spectrometer to that of a conventional transmission instrument. Spectral resolution was assessed by measuring the fwhm of various laser lines, which were found to range from 0.5 to 1.3 nm. The measured limits of detection for the waveguide spectrometer from 400 to 600 nm are 8.0 and 10.1 milliabsorbance units for TE and TM polarizations, respectively. Finally, to demonstrate the application of this technology to a molecular film confined to a solid-liquid interface, visible ATR spectra of an adsorbed submonolayer of horse heart cytochrome c were acquired. A procedure to correct the waveguide spectra for the wavelength dependence in ATR path length is described.


Assuntos
Espectrofotometria/métodos , Animais , Grupo dos Citocromos c/química , Cavalos , Óptica e Fotônica/instrumentação , Espectrofotometria/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...