Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Acad Radiol ; 28(7): 922-929, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33896717

RESUMO

INTRODUCTION: Black radiologists remain significantly underrepresented in the radiology workforce, despite a 1973 plea by Black radiologists of the National Medical Association to increase training programs for minority radiologists. OBJECTIVE: The authors provide a qualitative narrative that highlights the radiology residency programs of three historically Black schools of medicine (HBSOM) in the U.S., their contributions, and lessons learned from their closure. METHODS: Data from public repositories, interviews, and conversations were conflated to chronicle significant events and establish a timeline during these residency programs' existence. RESULTS: Radiology residencies at Howard University School of Medicine (1945), Meharry Medical College (1949), and Charles R. Drew University of Medicine and Science (1972) were established to train Black doctors to treat communities of color. These programs provided care to underserved and under-resourced areas of the country, where inequitable health care fueled a legacy of poor health outcomes. These radiology residency programs collapsed under the weight of suboptimal funding, strapped capital budgets, attrition of faculty, a declining hospital patient census, and failure to maintain other residency specialty programs.` CONCLUSION: Understanding the history and impact of these programs, and of their closure, can be leveraged to develop strategies to increase the representation of racial and ethnic minorities in radiology. Possible reinstatement, with appropriate allocation of resources and creation of intentional policies to ensure sustained success, merits further investigation and may be a pathway to achieve optimal representation.


Assuntos
Internato e Residência , Radiologia , Negro ou Afro-Americano , Humanos , Grupos Minoritários , Instituições Acadêmicas , Faculdades de Medicina , Estados Unidos
2.
J Am Coll Radiol ; 16(7): 983-991, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30745038

RESUMO

RATIONALE AND OBJECTIVES: Diagnostic radiology training programs are less diverse than graduating US medical school classes and the patient populations they serve. Inclusion of physicians who are underrepresented minorities in medicine (URMM) can strengthen the profession and help to meet the needs of an increasingly diverse population. Our Department of Radiology developed and implemented a plan to increase the number of URMMs in our residency applicant pool and residency training program. MATERIALS AND METHODS: We designed a recruitment strategy to diversify the radiology residency applicant pool. This included website development, advertising, early exposure opportunities, travel to predominantly minority institutions and national meetings, and mentoring URMM medical students. We implemented parallel activities to increase the number of URMMs in our residency program. These included holistic screening tools for residency application review, a diverse residency recruitment committee, a welcome environment for visiting candidates, and "Second Look Weekend" visits for talented candidates. Primary outcomes measured include change in percentages of URMM applicants in our applicant pool and URMM residents in our residency program. RESULTS: The percentage of URMM radiology residency applicants increased from 7.5% (42 of 556) of the total applicant pool in the 2012 to 2013 recruitment year to 12.6% (98 of 777) in the 2017 to 2018 recruitment year (P = .001). URMM radiology residency representation increased from 0% (0 of 32) in the 2013 to 2014 academic year to 20% (6 of 30) in the 2018 to 2019 academic year (P = .01). CONCLUSION: An intentional, strategic diversity program can diversify an institution's residency applicant pool and increase representation of URMMs in a diagnostic radiology residency program.


Assuntos
Educação de Pós-Graduação em Medicina/organização & administração , Educação de Graduação em Medicina/organização & administração , Grupos Minoritários/educação , Radiologia/organização & administração , Critérios de Admissão Escolar , Escolha da Profissão , Feminino , Humanos , Masculino , Avaliação das Necessidades , Avaliação de Programas e Projetos de Saúde , Faculdades de Medicina/organização & administração , Viés de Seleção , Estudantes de Medicina/estatística & dados numéricos , Estados Unidos
3.
Clin Nucl Med ; 43(12): 899-908, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30394933

RESUMO

Radiopharmaceuticals targeting cell surface expression of somatostatin receptors (SSTRs) are particularly useful in the evaluation of neuroendocrine tumors. Gallium-68 DOTA-Tyr-octreotatate (Ga-DOTATATE) primarily binds to SSTR type 2 receptors. Ga DOTATATE PET/CT is proven to have high impact on the management of neuroendocrine patients compared to traditional anatomical imaging as well as provides additional information over that of conventional nuclear medicine studies (indium-III DTPA-octreotide). It can result in change in management of approximately 75% of patients with neuroendocrine tumors. Ga DOTATATE and F FDG PET/CT imaging are complementary, with the degree of uptake varying depending on the degree of differentiation of the tumor. Well-differentiated tumors maintain their SSTRs and are positive on Ga DOTATATE PET/CT scan, while dedifferentiated tumors are less likely to demonstrate uptake of Ga DOTATATE but will demonstrate uptake with F FDG PET/CT. In addition, Ga DOTATATE PET/CT identifies patients with SSTR expression in their tumors, who have progressed on somatostatin analog therapy, for treatment with Lu DOTATATE.


Assuntos
Tumores Neuroendócrinos/diagnóstico por imagem , Compostos Organometálicos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Guias de Prática Clínica como Assunto , Radiologia/normas , Compostos Radiofarmacêuticos , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Sociedades Médicas
5.
J Nucl Med Technol ; 44(2): 94-5, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26271801

RESUMO

Left ventricular assist devices (LVADs) provide the ability to maintain cardiac output and sustain life as a bridge to transplantation, definitive therapy, or a permanent decision. We present a case of LVAD drive infection that was differentiated from pump infection by the use of attenuation-corrected and non-attenuation-corrected CT, along with correlation with the planar images. Clinically, the patient was suspected of having infection; however, the clinician did not know which components of the device were involved. The patient's scan showed abnormal activity along the driveline with and without attenuation correction, whereas the pump showed abnormal activity with attenuation correction only. This finding suggested that the drive line was infected but that the activity within the pump was secondary to overcorrection of attenuation. The driveline was cultured, confirming infection.


Assuntos
Coração Auxiliar/efeitos adversos , Processamento de Imagem Assistida por Computador , Infecções Relacionadas à Prótese/diagnóstico por imagem , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/etiologia
6.
Clin Imaging ; 39(4): 642-5, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25794849

RESUMO

OBJECTIVE: To compare the radiographic density of renal cysts on contrast-enhanced computed tomography (CT) scans performed at tube voltages of 100 versus 120 kVp. METHODS: Thirty-six renal cysts from contrast-enhanced CT performed on 21 subjects at both 120 kVp and 100 kVp were compared by Kolmogorov-Smirnov statistical testing. RESULTS: The radiographic density (mean+/-standard deviation in Hounsfield units) of cysts was greater on 100-kVp than on 120-kVp CT scans for both 5-mm and 2-mm reconstructed slice thicknesses: 16.6+/-5.6 versus 10.9+/-4.9 and 14.1+/-5.6 versus 8.5+/-3.9, respectively. CONCLUSIONS: Decrease in tube voltage significantly increases measured radiographic density of renal cysts on CT. Further studies are indicated to assess the clinical impact of lower-tube-voltage CT.


Assuntos
Doenças Renais Císticas/diagnóstico por imagem , Meios de Contraste , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
7.
World J Urol ; 31(6): 1327-32, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23595605

RESUMO

PURPOSE: To preliminarily evaluate the potential for an improvement in diagnostic performance by a combined interpretation of In-111 capromab pendetide single photon emission computed tomography (SPECT) including computed tomography (CT) image fusion with magnetic resonance diffusion-weighted imaging (MR-DWI) for identifying prostate cancer in pelvic lymph nodes thru correlation with histopathology. MATERIALS AND METHODS: This institutional approved, retrospective study identified patients with available histopathology of lymph nodes removed at the time of radical prostatectomy and who had undergone staging with In-111 capromab pendetide SPECT-CT and/or pelvic MRI (including DWI). The performance of In-111 capromab pendetide SPECT for identifying malignant lymph nodes was assessed. Subsequently, a combined reading of In-111 capromab pendetide SPECT and prostate MRI with DWI was performed and the performance assessed. RESULTS: 18 patients underwent In-111 capromab pendetide SPECT-CT. Of these, 12 patients had also undergone imaging with MR-DWI. In-111 capromab pendetide SPECT-CT had a sensitivity of 40.0% and specificity of 96.7% for identification of malignant lymph nodes. However, In-111 capromab pendetide SPECT-CT combined with MRI with DWI had a sensitivity of 88.9% and specificity of 98.5%. CONCLUSIONS: The addition of MR-DWI to the interpretation of In-111 capromab pendetide SPECT-CT may increase the sensitivity for detecting malignant lymph nodes in prostate cancer. Future prospective evaluation of combined In-111 capromab pendetide SPECT-CT and MR-DWI is indicated and may improve clinical evaluation of nodal disease in prostate cancer.


Assuntos
Anticorpos Monoclonais , Imagem de Difusão por Ressonância Magnética , Radioisótopos de Índio , Neoplasias Pélvicas/diagnóstico , Neoplasias da Próstata/patologia , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Humanos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Metástase Linfática/diagnóstico , Masculino , Pessoa de Meia-Idade , Neoplasias Pélvicas/secundário , Estudos Prospectivos , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Estudos Retrospectivos , Sensibilidade e Especificidade
11.
Med Phys ; 31(4): 800-13, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15124997

RESUMO

The purpose of this simulation study was to evaluate the feasibility, benefits, and potential operating parameters of a quasi-monochromatic beam from a tungsten-target x-ray source yielding projection images. The application is intended for newly developed cone beam computed mammotomography (CmT) of an uncompressed breast. The value of a near monochromatic x-ray source for a fully 3D CmT application is the expected improved ability to separate tissues with very small differences in attenuation coefficients. The quasi-monochromatic beam is expected to yield enhanced tomographic image quality along with a low dose, equal to or less than that of dual view x-ray mammography. X-ray spectra were generated with a validated projection x-ray simulation tool (XSpect) for a range of tungsten tube potentials (40-100 kVp), filter materials (Z=51-65), and filter thicknesses (10th to 1000th value layer determined at 60 kVp). The breast was modeled from ICRU-44 breast tissue specifications, and a breast lesion was modeled as a 0.5 cm thick mass. The detector was modeled as a digital flat-panel detector with a 0.06 cm thick CsI x-ray absorption layer. Computed figures of merit (FOMs) included the ratio of mean beam energy post-breast to pre-breast and the ratio of lesion contrasts for edge-located and center-located lesions as indices of breast beam hardening, and SNR2/exposure and SNR2/dose as indices of exposure and dose efficiencies. The impact of optimization of these FOMs on lesion contrast is also examined. For all simulated filter materials at each given attenuation thickness [10th, 100th, 500th, 1000th value layers (VLs)], the mean and standard deviation of the pre-breast spectral full-width at tenth-maximum (FWTM) were 16.1 +/- 2.4, 10.3 +/- 2.2, 7.3 +/- 1.4, and 6.5 +/- 1.5 keV, respectively. The change in beam width at the tenth maximum from pre-breast to post-breast spectra ranged from 4.7 to 1.1 keV, for the thinnest and thickest filters, respectively. The higher Z filters (Z=57-63) produced a quasi-monochromatic beam that allowed the widest tube potential operating range (50-70 kVp) while maintaining minimal beam hardening and maximal SNR2/exposure and SNR2/dose, and providing a contrast greater than that obtained in the unfiltered case. Figures of merit improved with increasing filter thickness, with diminishing returns beyond the 500th value layer attenuation level. Operating parameters required to produce optimal spectra, while keeping exposures equal to that of dual view mammography, are within the capability of the commercial x-ray tube proposed for our experimental study, indicating that use of these highly attenuating filters is viable. Additional simulations comparing Mo/Mo, Mo/Rh, and W/Rh target/filter combinations indicate that they exhibit significantly lower SNR2/exposure than the present approach, precluding them from being used for computed mammotomography, while maintaining dose limitations and obtaining sufficient SNR. Beam hardening was also much higher in the existing techniques (17%-42%) than for our technique (2%). Simulations demonstrate that this quasi-monochromatic x-ray technique may enhance tissue separation for a newly developed cone beam computed mammotomography application for an uncompressed breast.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/fisiopatologia , Mama/fisiopatologia , Análise de Falha de Equipamento/métodos , Mamografia/instrumentação , Modelos Biológicos , Tomografia Computadorizada por Raios X/instrumentação , Simulação por Computador , Desenho Assistido por Computador , Desenho de Equipamento , Feminino , Humanos , Mamografia/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...