J Clin Monit Comput ; 29(3): 323-31, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25355556

RESUMO

This prospective single-center study aimed to determine the responsiveness and diagnostic performance of continuous cardiac output (CCO) monitors based on pulse contour analysis compared with invasive mean arterial pressure (MAP) during predefined periods of acute circulatory deterioration in patients undergoing transcatheter aortic valve implantation (TAVI). The ability of calibrated (CCO(CAL)) and self-calibrated (CCO(AUTOCAL)) pulse contour analysis to detect the hemodynamic response to 37 episodes of balloon aortic valvuloplasty enabled by rapid ventricular pacing was quantified in 13 patients undergoing TAVI. A "low" and a "high" cut-off limit were predefined as a 15 or 25 % decrease from baseline respectively. We found no significant differences between CCO(CAL) and MAP regarding mean response time [low cut-off: 8.6 (7.1-10.5) vs. 8.9 (7.3-10.8) s, p = 0.76; high cut-off: 11.4 (9.7-13.5) vs. 12.6 (10.7-14.9) s, p = 0.32] or diagnostic performance [area under the receiver operating characteristics curve (AUC): 0.99 (0.98-1.0) vs. 1.0 (0.99-1.0), p = 0.46]. But CCOCAL had a significantly higher amplitude response [95.0 (88.7-98.8) % decrease from baseline] than MAP [41.2 (30.0-52.9) %, p < 0.001]. CCOAUTOCAL had a significantly lower AUC [0.83 (0.73-0.93), p < 0.001] than MAP. Moreover, CCO(CAL) detected hemodynamic recovery significantly earlier than MAP. In conclusion, CCO(CAL) and MAP provided equivalent responsiveness and diagnostic performance to detect acute circulatory depression, whereas CCO(AUTOCAL) appeared to be less appropriate. In contrast to CCO(CAL) the amplitude response of MAP was poor. Consequently even small response amplitudes of MAP could indicate severe decreases in CO.


Assuntos
Débito Cardíaco/fisiologia , Monitorização Fisiológica/métodos , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Área Sob a Curva , Valvuloplastia com Balão , Calibragem , Sistemas Computacionais , Feminino , Frequência Cardíaca , Hemodinâmica , Humanos , Masculino , Estudos Prospectivos , Curva ROC , Processamento de Sinais Assistido por Computador , Termodiluição , Resultado do Tratamento
2.
Intensive Care Med ; 39(4): 601-11, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23287875

RESUMO

PURPOSE: Transcardiopulmonary thermodilution (TPTD, SVTD) as well as calibrated (SVPC CAL) and uncalibrated (SVPC UNCAL) arterial pulse contour analysis (PC) are increasingly promoted as less-invasive technologies to measure stroke volume (SV) but their reliability in aortic valve disease was unknown. The objective of this prospective study was to investigate the validity of three less-invasive techniques to assess SV in conditions involving aortic stenosis (AS) and valvuloplasty-induced aortic insufficiency (AI) compared with transesophageal echocardiography. METHODS: In 18 patients undergoing transcatheter aortic valve implantation, SVTD and SVPC CAL were determined using a central pressure signal via the brachial artery and SVPC UNCAL using a peripheral radial signal. RESULTS: In aortic valve dysfunction TPTD achieved adequate reproducibility (concordance correlation coefficient (CCC): AS 0.84; AI 0.82) and agreement (percentage error (PE): AS 26.3 %; AI 26.2 %) with the reference technique. In severe AS, SVPC CAL (PE 25.7 %; CCC 0.85) but not SVPC UNCAL (PE 50.4 %; CCC 0.38) was reliable. Neither calibrated nor uncalibrated PC (SVPC CAL: PE 51.5 %; CCC 0.49; SVPC UNCAL: PE 61.9 %; CCC 0.22) was valid in AI. Trending ability to hemodynamic changes, quantified by the ΔSV vector and the angle θ, was acceptable for each measurement modality. CONCLUSIONS: Transcardiopulmonary thermodilution is valid in aortic valve dysfunction. Calibration of PC substantially improves reliability in aortic valve disease. Calibrated PC is valid in severe AS. Valvuloplasty-induced AI seriously confounds PC measurements. In uncalibrated PC approaches, the relative SV trend is superior to single absolute values.


Assuntos
Débito Cardíaco/fisiologia , Cardiopatias Congênitas/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide , Feminino , Alemanha , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/fisiopatologia , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Masculino , Estudos Prospectivos , Pulso Arterial , Volume Sistólico/fisiologia , Termodiluição/métodos