Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Phys Chem A ; 128(9): 1685-1697, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38394372

RESUMO

We present combined theoretical and experimental work investigating the angle-resolved phases of the photoionization process driven by a two-color field consisting of an attosecond pulse train and an infrared pulse in an ensemble of randomly oriented molecules. We derive a general form for the two-color photoelectron (and time-delay) angular distribution valid also in the case of chiral molecules and when relative polarizations of the photons contributing to the attosecond photoelectron interferometer differ. We show a comparison between the experimental data and theoretical predictions in an ensemble of methane and deuteromethane molecules, discussing the effect of nuclear dynamics on the photoionization phases. Finally, we demonstrate that the oscillating component and the phase of the two-color signal can be fitted by using complex asymmetry parameters, in perfect analogy to the atomic case.

3.
Lab Chip ; 24(1): 34-46, 2023 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-37791882

RESUMO

Heterogeneity investigation at the single-cell level reveals morphological and phenotypic characteristics in cell populations. In clinical research, heterogeneity has important implications in the correct detection and interpretation of prognostic markers and in the analysis of patient-derived material. Among single-cell analysis, imaging flow cytometry allows combining information retrieved by single cell images with the throughput of fluidic platforms. Nevertheless, these techniques might fail in a comprehensive heterogeneity evaluation because of limited image resolution and bidimensional analysis. Light sheet fluorescence microscopy opened new ways to study in 3D the complexity of cellular functionality in samples ranging from single-cells to micro-tissues, with remarkably fast acquisition and low photo-toxicity. In addition, structured illumination microscopy has been applied to single-cell studies enhancing the resolution of imaging beyond the conventional diffraction limit. The combination of these techniques in a microfluidic environment, which permits automatic sample delivery and translation, would allow exhaustive investigation of cellular heterogeneity with high throughput image acquisition at high resolution. Here we propose an integrated optofluidic platform capable of performing structured light sheet imaging flow cytometry (SLS-IFC). The system encompasses a multicolor directional coupler equipped with a thermo-optic phase shifter, cylindrical lenses and a microfluidic network to generate and shift a patterned light sheet within a microchannel. The absence of moving parts allows a stable alignment and an automated fluorescence signal acquisition during the sample flow. The platform enables 3D imaging of an entire cell in about 1 s with a resolution enhancement capable of revealing sub-cellular features and sub-diffraction limit details.


Assuntos
Imageamento Tridimensional , Microfluídica , Humanos , Microscopia de Fluorescência/métodos , Citometria de Fluxo/métodos , Imageamento Tridimensional/métodos
4.
Opt Express ; 30(17): 30246-30259, 2022 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-36242132

RESUMO

Structured Illumination Microscopy (SIM) is a key technology for high resolution and super-resolution imaging of biological cells and molecules. The spread of portable and easy-to-align SIM systems requires the development of novel methods to generate a light pattern and to shift it across the field of view of the microscope. Here we show a miniaturized chip that incorporates optical waveguides, splitters, and phase shifters, to generate a 2D structured illumination pattern suitable for SIM microscopy. The chip creates three point-sources, coherent and controlled in phase, without the need for further alignment. Placed in the pupil of a microscope's objective, the three sources generate a hexagonal illumination pattern on the sample, which is spatially translated thanks to thermal phase shifters. We validate and use the chip, upgrading a commercial inverted fluorescence microscope to a SIM setup and we image biological sample slides, extending the resolution of the microscope.


Assuntos
Iluminação , Dispositivos Ópticos , Microscopia de Fluorescência/métodos
5.
Lab Chip ; 22(18): 3453-3463, 2022 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-35946995

RESUMO

Single-cell imaging and sorting are critical technologies in biology and clinical applications. The power of these technologies is increased when combined with microfluidics, fluorescence markers, and machine learning. However, this quest faces several challenges. One of these is the effect of the sample flow velocity on the classification performances. Indeed, cell flow speed affects the quality of image acquisition by increasing motion blur and decreasing the number of acquired frames per sample. We investigate how these visual distortions impact the final classification task in a real-world use-case of cancer cell screening, using a microfluidic platform in combination with light sheet fluorescence microscopy. We demonstrate, by analyzing both simulated and experimental data, that it is possible to achieve high flow speed and high accuracy in single-cell classification. We prove that it is possible to overcome the 3D slice variability of the acquired 3D volumes, by relying on their 2D sum z-projection transformation, to reach an efficient real time classification with an accuracy of 99.4% using a convolutional neural network with transfer learning from simulated data. Beyond this specific use-case, we provide a web platform to generate a synthetic dataset and to investigate the effect of flow speed on cell classification for any biological samples and a large variety of fluorescence microscopes (https://www.creatis.insa-lyon.fr/site7/en/MicroVIP).


Assuntos
Algoritmos , Microfluídica , Aprendizado de Máquina , Microscopia de Fluorescência , Redes Neurais de Computação
6.
Micromachines (Basel) ; 13(2)2022 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-35208275

RESUMO

Femtosecond laser micromachining is becoming an established fabrication technique for transparent material processing in three dimensions [...].

7.
Sci Rep ; 12(1): 239, 2022 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-34997131

RESUMO

We present an optimization of the dynamics of integrated optical switches based on thermal phase shifters. These devices have been fabricated in the volume of glass substrates by femtosecond laser micromachining and are constituted by an integrated Mach-Zehnder interferometer and a superficial heater. Simulations, surface micromachining and innovative layouts allowed us to improve the temporal response of the optical switches down to a few milliseconds. In addition, taking advantage of an electrical pulse shaping approach where an optimized voltage signal is applied to the heater, we proved a switching time as low as 78 µs, about two orders of magnitude shorter with respect to the current state of the art of thermally-actuated optical switches in glass.

8.
Micromachines (Basel) ; 12(2)2021 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-33670373

RESUMO

Femtosecond laser micromachining (FLM) of fused silica allows for the realization of three-dimensional embedded optical elements and microchannels with micrometric feature size. The performances of these components are strongly affected by the machined surface quality and residual roughness. The polishing of 3D buried structures in glass was demonstrated using different thermal annealing processes, but precise control of the residual roughness obtained with this technique is still missing. In this work, we investigate how the FLM irradiation parameters affect surface roughness and we characterize the improvement of surface quality after thermal annealing. As a result, we achieved a strong roughness reduction, from an average value of 49 nm down to 19 nm. As a proof of concept, we studied the imaging performances of embedded mirrors before and after thermal polishing, showing the capacity to preserve a minimum feature size of the reflected image lower than µ5µm. These results allow for us to push forward the capabilities of this enabling fabrication technology, and they can be used as a starting point to improve the performances of more complex optical elements, such as hollow waveguides or micro-lenses.

9.
Soft Matter ; 17(11): 3105-3112, 2021 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-33598667

RESUMO

Yield stress materials deform as elastic solids or flow as viscous liquids, depending on the applied stress, which also allows them to trap particles below a certain size or density threshold. To investigate the conditions for such a transition at the microscale, we use an optofluidic microrheometer, based on the scattering of an infrared beam onto a microbead, which reaches forces in the nN scale. We perform creep experiments on a model soft material composed of swollen microgels, determining the limits of linear response and yield stress values, and observe quantitative agreement with bulk measurements. However, the motion of the microbead, both below and above yielding, reflects distinctive microscale features of the surrounding material, whose plastic rearrangements were investigated by us using small, passive tracers.

10.
J Biophotonics ; 14(3): e202000396, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33295053

RESUMO

We present a microscope on chip for automated imaging of Drosophila embryos by light sheet fluorescence microscopy. This integrated device, constituted by both optical and microfluidic components, allows the automatic acquisition of a 3D stack of images for specimens diluted in a liquid suspension. The device has been fully optimized to address the challenges related to the specimens under investigation. Indeed, the thickness and the high ellipticity of Drosophila embryos can degrade the image quality. In this regard, optical and fluidic optimization has been carried out to implement dual-sided illumination and automatic sample orientation. In addition, we highlight the dual color investigation capabilities of this device, by processing two sample populations encoding different fluorescent proteins. This work was made possible by the versatility of the used fabrication technique, femtosecond laser micromachining, which allows straightforward fabrication of both optical and fluidic components in glass substrates.


Assuntos
Drosophila , Microfluídica , Animais , Lasers , Microscopia de Fluorescência , Microtecnologia
11.
Biomed Opt Express ; 11(8): 4397-4407, 2020 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-32923051

RESUMO

Single-cell analysis techniques are fundamental to study the heterogeneity of cellular populations, which is the basis to understand several biomedical mechanisms. Light-sheet fluorescence microscopy is a powerful technique for obtaining high-resolution imaging of individual cells, but the complexity of the setup and the sample mounting procedures limit its overall throughput. In our work, we present an optofluidic microscope-on-chip with integrated microlenses for light-sheet shaping and with a fluidic microchannel that allows the automatic and continuous delivery of samples of a few tens of microns in size. The device is used to perform dual-color fluorescence analysis and 3D reconstruction of xenograft-derived mouse breast cancer cells.

12.
Sci Rep ; 10(1): 5831, 2020 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-32242060

RESUMO

We propose and demonstrate an on-chip optofluidic device allowing active oscillatory microrheological measurements with sub-µL sample volume, low cost and high flexibility. Thanks to the use of this optofluidic microrheometer it is possible to measure the viscoelastic properties of complex fluids in the frequency range 0.01-10 Hz at different temperatures. The system is based on the optical forces exerted on a microbead by two counterpropagating infrared laser beams. The core elements of the optical part, integrated waveguides and an optical modulator, are fabricated by fs-laser writing on a glass substrate. The system performance is validated by measuring viscoelastic solutions of aqueous worm-like micelles composed by Cetylpyridinium Chloride (CPyCl) and Sodium Salicylate (NaSal).

13.
Micromachines (Basel) ; 9(5)2018 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-30424133

RESUMO

Since the pioneering work of Ashkin and coworkers, back in 1970, optical manipulation gained an increasing interest among the scientific community. Indeed, the advantages and the possibilities of this technique are unsubtle, allowing for the manipulation of small particles with a broad spectrum of dimensions (nanometers to micrometers size), with no physical contact and without affecting the sample viability. Thus, optical manipulation rapidly found a large set of applications in different fields, such as cell biology, biophysics, and genetics. Moreover, large benefits followed the combination of optical manipulation and microfluidic channels, adding to optical manipulation the advantages of microfluidics, such as a continuous sample replacement and therefore high throughput and automatic sample processing. In this work, we will discuss the state of the art of these optofluidic devices, where optical manipulation is used in combination with microfluidic devices. We will distinguish on the optical method implemented and three main categories will be presented and explored: (i) a single highly focused beam used to manipulate the sample, (ii) one or more diverging beams imping on the sample, or (iii) evanescent wave based manipulation.

14.
Cytometry A ; 93(10): 987-996, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30211977

RESUMO

Last decade's advancements in optofluidics allowed obtaining an ever increasing integration of different functionalities in lab on chip devices to culture, analyze, and manipulate single cells and entire biological specimens. Despite the importance of optical imaging for biological sample monitoring in microfluidics, imaging is traditionally achieved by placing microfluidics channels in standard bench-top optical microscopes. Recently, the development of either integrated optical elements or lensless imaging methods allowed optical imaging techniques to be implemented in lab on chip systems, thus increasing their automation, compactness, and portability. In this review, we discuss known solutions to implement microscopes on chip that exploit different optical methods such as bright-field, phase contrast, holographic, and fluorescence microscopy.


Assuntos
Técnicas Analíticas Microfluídicas/métodos , Microfluídica/instrumentação , Microfluídica/métodos , Microscopia/instrumentação , Microscopia/métodos , Imagem Óptica/instrumentação , Imagem Óptica/métodos , Automação/instrumentação , Automação/métodos , Holografia/instrumentação , Holografia/métodos , Humanos , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas/instrumentação
15.
Soft Matter ; 14(17): 3288-3295, 2018 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-29691545

RESUMO

The viscosity of gel-forming fluids is notoriously complex and its study can benefit from new model systems that enable a detailed control of the network features. Here we use a novel and simple microfluidic-based active microrheology approach to study the transition from Newtonian to non-Newtonian behavior in a DNA hydrogel whose structure, connectivity, density of bonds, bond energy and kinetics are strongly temperature dependent and well known. In a temperature range of 15 °C, the system reversibly and continuously transforms from a Newtonian dispersion of low-valence nanocolloids into a strongly shear-thinning fluid, passing through a set of intermediate states where it behaves as a power-law fluid. We demonstrate that the knowledge of network topology and bond free energy enables to quantitatively predict the observed behavior using established rheology models.

16.
Opt Express ; 25(7): 7313-7323, 2017 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-28380855

RESUMO

Microfluidic lenses are relevant optical components for sensing application in lab-on-a-chip devices, guaranteeing a robust alignment of the elements, a high level of compactness and tunable optical properties. In this work we describe an innovative integrated in-plane microfluidic lens. The device shows both an optimized shape capable of reducing spherical aberrations and periodically tunable optical properties. Indeed through the combination of the lens with a droplet generator module, we have been able to obtain an integrated optofluidic modulator capable of both on-demand on/off switching and periodic modulation of light. The device possesses a simple 3D geometry, which has been realized by exploiting the 3D capability of the femtosecond laser micromachining fabrication technique.

18.
Sci Rep ; 7: 39989, 2017 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-28067265

RESUMO

Understanding of material behaviour at nanoscale under intense laser excitation is becoming critical for future application of nanotechnologies. Nanograting formation by linearly polarised ultra-short laser pulses has been studied systematically in fused silica for various pulse energies at 3D laser printing/writing conditions, typically used for the industrial fabrication of optical elements. The period of the nanogratings revealed a dependence on the orientation of the scanning direction. A tilt of the nanograting wave vector at a fixed laser polarisation was also observed. The mechanism responsible for this peculiar dependency of several features of the nanogratings on the writing direction is qualitatively explained by considering the heat transport flux in the presence of a linearly polarised electric field, rather than by temporal and spatial chirp of the laser beam. The confirmed vectorial nature of the light-matter interaction opens new control of material processing with nanoscale precision.

19.
Microsyst Nanoeng ; 3: 17027, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-31057868

RESUMO

Three-dimensional (3D) particle focusing in microfluidics is a fundamental capability with a wide range of applications, such as on-chip flow cytometry, where high-throughput analysis at the single-cell level is performed. Currently, 3D focusing is achieved mainly in devices with complex layouts, additional sheath fluids, and complex pumping systems. In this work, we present a compact microfluidic device capable of 3D particle focusing at high flow rates and with a small footprint, without the requirement of external fields or lateral sheath flows, but using only a single-inlet, single-outlet microfluidic sequence of straight channels and tightly curving vertical loops. This device exploits inertial fluidic effects that occur in a laminar regime at sufficiently high flow rates, manipulating the particle positions by the combination of inertial lift forces and Dean drag forces. The device is fabricated by femtosecond laser irradiation followed by chemical etching, which is a simple two-step process enabling the creation of 3D microfluidic networks in fused silica glass substrates. The use of tightly curving three-dimensional microfluidic loops produces strong Dean drag forces along the whole loop but also induces an asymmetric Dean flow decay in the subsequent straight channel, thus producing rapid cross-sectional mixing flows that assist with 3D particle focusing. The use of out-of-plane loops favors a compact parallelization of multiple focusing channels, allowing one to process large amounts of samples. In addition, the low fluidic resistance of the channel network is compatible with vacuum driven flows. The resulting device is quite interesting for high-throughput on-chip flow cytometry.

20.
Lab Chip ; 16(9): 1556-60, 2016 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-27030116

RESUMO

Selective plane illumination microscopy can image biological samples at a high spatiotemporal resolution. Complex sample preparation and system alignment normally limit the throughput of the method. Using femtosecond laser micromachining, we created an integrated optofluidic device that allows obtaining continuous flow imaging, three-dimensional reconstruction and high-throughput analysis of large multicellular spheroids at a subcellular resolution.


Assuntos
Ensaios de Triagem em Larga Escala/instrumentação , Imageamento Tridimensional/instrumentação , Dispositivos Lab-On-A-Chip , Microscopia de Fluorescência/métodos , Animais , Desenho de Equipamento , Histonas/química , Histonas/genética , Histonas/metabolismo , Humanos , Proteínas Luminescentes/química , Proteínas Luminescentes/genética , Proteínas Luminescentes/metabolismo , Microscopia de Fluorescência/instrumentação , Nanopartículas/química , Proteínas Recombinantes de Fusão/metabolismo , Análise de Célula Única/instrumentação , Esferoides Celulares/citologia , Proteína Vermelha Fluorescente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...