Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Biomed Opt ; 23(8): 1-11, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-30094972

RESUMO

Diagnostic accuracy of needle-based optical coherence tomography (OCT) for prostate cancer detection by visual and quantitative analysis is defined. 106 three-dimensional (3-D)-OCT data sets were acquired in 20 prostates after radical prostatectomy and precisely matched with pathology. OCT images were grouped per histological category. Two reviewers performed blind assessments of the OCT images. Sensitivity and specificity for malignancy detection were calculated. Quantitative analyses by automated optical attenuation coefficient calculation were performed. OCT can reliably differentiate between fat, cystic, and regular atrophy and benign glands. The overall sensitivity and specificity for malignancy detection was 79% and 88% for reviewer 1 and 88% and 81% for reviewer 2. Quantitative analysis for differentiation between stroma and malignancy showed a significant difference (4.6 mm - 1 versus 5.0 mm - 1 Mann-Whitney U-test p < 0.0001). A Kruskal-Wallis test showed a significant difference in median attenuation coefficient between stroma, inflammation, Gleason 3, and Gleason 4 (4.6, 4.1, 5.9, and 5.0 mm - 1, respectively). However, attenuation coefficient varied per patient and a related-samples Wilcoxon signed-rank test showed no significant difference per patient (p = 0.17). This study confirmed the one to one correlation of histopathology and OCT. Precise matching showed that most histological tissues categories in the prostate could be distinguished by their unique pattern in OCT images. In addition, the optical attenuation coefficient can play a role in the differentiation between stroma and malignancy; however, a per patient analysis of the optical attenuation coefficient did not show a significant difference.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Adulto , Humanos , Masculino , Agulhas , Estudos Prospectivos , Próstata/patologia , Neoplasias da Próstata/patologia , Sensibilidade e Especificidade
2.
J Med Imaging (Bellingham) ; 5(1): 017001, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29487884

RESUMO

Minimal invasive endoscopic treatment for upper urinary tract urothelial carcinoma (UUT-UC) is advocated in patients with low-risk disease and limited tumor volume. Diagnostic ureterorenoscopy combined with biopsy is the diagnostic standard. This study aims to evaluate two alternative diagnostic techniques for UUT-UC: optical coherence tomography (OCT) and endoluminal ultrasound (ELUS). Following nephroureterectomy, OCT, ELUS, and computed tomography (CT) were performed of the complete nephroureterectomy specimen. Visualization software (AMIRA®) was used for reconstruction and coregistration of CT, OCT, and ELUS. Finally, CT was used to obtain exact probe localization. Coregistered OCT and ELUS datasets were compared with histology. Coregistration with three-dimensional CT makes exact data matching possible in this ex-vivo setting to compare histology with OCT and ELUS. In OCT images of normal-appearing renal pelvis and ureter, urothelium, lamina propria, and muscularis were visible. With ELUS, all anatomical layers of the ureter could be distinguished, besides the urothelial layer. ELUS identified suspect lesions, although exact staging and differentiation between noninvasive and invasive lesions were not possible. OCT provides high-resolution imaging of normal ureter and ureter lesions. ELUS, however, is of limited value as it cannot differentiate between noninvasive and invasive tumors.

3.
J Biophotonics ; 9(5): 490-8, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26856796

RESUMO

The diagnostic accuracy of Optical Coherence Tomography (OCT) based optical attenuation coefficient analysis is assessed for the detection of prostate cancer. Needle-based OCT-measurements were performed on the prostate specimens. Attenuation coefficients were determined by an earlier described in-house developed software package. The mean attenuation coefficients (benign OCT data; malignant OCT data; p-value Mann-Whitney U test) were: (3.56 mm(-1) ; 3.85 mm(-1) ; p < 0.0001) for all patients combined. The area under the ROC curve was 0.64. In order to circumvent the effect of histopathology mismatching, we performed a sub-analysis on only OCT data in which tumor was visible in two subsequent histopathological prostate slices. This analysis could be performed in 3 patients. The mean attenuation coefficients (benign OCT data; malignant OCT data; p-value Mann-Whitney U test) were: (3.23 mm(-1) ; 4.11 mm(-1) ; p < 0.0001) for all patients grouped together. The area under the ROC curve was 0.89. Functional OCT of the prostate has shown to differentiate between cancer and healthy prostate tissue. The optical attenuation coefficient in malignant tissue was significantly higher in malignant tissue compared to benign prostate tissue. Further studies are required to validate these initial results in a larger group of patients with a more tailored histopathology matching protocol.


Assuntos
Neoplasias da Próstata/diagnóstico por imagem , Tomografia de Coerência Óptica , Humanos , Masculino , Agulhas
4.
J Endourol ; 30(5): 602-8, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26743929

RESUMO

OBJECTIVES: To evaluate the variation of interpretation of the same bladder urothelium image in different Storz Professional Image Enhancement System (SPIES) modalities. SPIES contains a White light (WL), Spectra A (SA), Spectra B (SB), and Clara and Chroma combined (CC) modality. MATERIALS AND METHODS: An App for the iPAD retina was developed to study evaluation of images. A total of 80 images from 20 bladder areas acquired in four modalities were included. Seventy-three participants completed the study. Images were analyzed on differences in delineated tumor margin variation, perceived quality of the image, and delineation time. RESULTS: A separation between high agreement (n = 14) and low agreement (n = 6) images was found. In high agreement images, no difference in root mean square (RMS) was found between modalities. In low agreement images, WL (26.5 pixels) and SA (33.4 pixels) had a higher RMS than CC (18 pixels) and SB (21.4 pixels). The quality of SPIES modalities images was rated significantly higher. Delineation time was similar. CONCLUSION: In low agreement cases, images in CC and SB have less variation in interpretation than WL and SA. The image quality in SPIES modalities is graded significantly higher than WL. There is no difference in delineation time between modalities.


Assuntos
Aumento da Imagem/métodos , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Urotélio/diagnóstico por imagem , Adulto , Idoso , Computadores de Mão , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Aplicativos Móveis , Variações Dependentes do Observador , Software , Inquéritos e Questionários , Adulto Jovem
5.
J Med Imaging (Bellingham) ; 2(3): 037501, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26171414

RESUMO

The objective of this study is to demonstrate the feasibility of needle-based optical coherence tomography (OCT) and functional analysis of OCT data along the full pullback trajectory of the OCT measurement in the prostate, correlated with pathology. OCT images were recorded using a commercially available C7-XR™ OCT Intravascular Imaging System interfaced to a C7 Dragonfly™ intravascular 0.9-mm-diameter imaging probe. A computer program was constructed for automated image attenuation analysis. First, calibration of the OCT system for both the point spread function and the system roll-off was achieved by measurement of the OCT signal attenuation from an extremely weakly scattering medium (Intralipid® 0.0005 volume%). Second, the data were arranged in 31 radial wedges (pie slices) per circular segments consisting of 16 A-scans per wedge and 5 axial B-scans, resulting in an average A-scan per wedge. Third, the decay of the OCT signal is analyzed over 50 pixels ([Formula: see text]) in depth, starting from the first found maximum data point. Fourth, for visualization, the data were grouped with a corresponding color representing a specific [Formula: see text] range according to their attenuation coefficient. Finally, the analyses were compared to histopathology. To ensure that each single use sterile imaging probe is comparable to the measurements of the other imaging probes, the probe-to-probe variations were analyzed by measuring attenuation coefficients of 0.03, 6.5, 11.4, 17, and 22.7 volume% Intralipid®. Experiments were repeated five times per probe for four probes. Inter- and intraprobe variation in the measured attenuation of Intralipid samples with scattering properties similar to that of the prostate was [Formula: see text] of the mean values. Mean attenuation coefficients in the prostate were [Formula: see text] for parts of the tissue that were classified as benign (SD: [Formula: see text], minimum: [Formula: see text], maximum: [Formula: see text]) and [Formula: see text] for parts of tissue that were classified as malignant (SD: [Formula: see text], minimum: [Formula: see text], maximum: [Formula: see text]). In benign areas, the tissue looked homogeneous, whereas in malignant areas, small glandular structures were seen. However, not all areas in which a high attenuation coefficient became apparent corresponded to areas of prostate cancer. This paper describes the first in-tissue needle-based OCT imaging and three-dimensional optical attenuation analysis of prostate tissue that indicates a correlation with pathology. Fully automated attenuation coefficient analysis was performed at 1300 nm over the full pullback. Correlation with pathology was achieved by coregistration of three-dimensional (3-D) OCT attenuation maps with 3-D pathology of the prostate. This may contribute to the current challenge of prostate imaging and the rising interest in focal therapy for reduction of side effects occurring with current therapies.

6.
Acta Orthop ; 86(2): 257-63, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25350610

RESUMO

BACKGROUND AND PURPOSE: Optical coherence tomography (OCT) is a light-based imaging technique suitable for depiction of thin tissue layers such as articular cartilage. Quantification of results and direct comparison with a reference standard is needed to confirm the role of OCT in cartilage evaluation. MATERIALS AND METHODS: Goat talus articular cartilage repair was assessed quantitatively with OCT and compared with histopathology using semi-automated analysis software. Osteochondral defects were created centrally in goat tali with subsequent healing over 24 weeks. After sacrifice, the tali were analyzed using OCT and processed into histopathology slides. Cartilage thickness, repair tissue area, and surface roughness were measured. Also, light attenuation coefficient measurements were performed to assess differences in the properties of healthy tissue and repair tissue. RESULTS: Intra-class correlation coefficients for resemblance between the 2 techniques were 0.95 (p < 0.001) for thickness, 0.73 (p = 0.002) for repair tissue area, and 0.63 (p = 0.015) for surface roughness. Light attenuation differed significantly between healthy cartilage (8.2 (SD 3.9) mm(-1)) and repair tissue (2.8 (SD 1.5) mm(-1)) (p < 0.001). INTERPRETATION: Compared to histopathology as the standard reference method, OCT is a reproducible technique in quantitative analysis of goat talus articular cartilage, especially when assessing cartilage thickness and to a lesser extent when measuring repair tissue area and surface roughness. Moreover, differences in local light attenuation suggest measurable variation in tissue structure, enhancing the clinical applicability of quantitative measurements from cartilage OCT images.


Assuntos
Articulação do Tornozelo/patologia , Cartilagem Articular/patologia , Tálus/patologia , Tomografia de Coerência Óptica , Cicatrização , Animais , Cartilagem Articular/cirurgia , Feminino , Cabras , Processamento de Imagem Assistida por Computador , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...