Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Am Coll Radiol ; 8(11): 795-803, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22051465

RESUMO

PURPOSE: The aim of this study was to assess the distribution of CT dose index (CTDI) values reported by sites undergoing ACR CT accreditation between 2002 and 2004. METHODS: Weighted CTDI (CTDI(w)) values were measured and reported by sites applying for ACR CT accreditation, and the percentage of scanners with values above the 2002 ACR diagnostic reference levels (DRLs) was determined. Acquisition parameters for a site's adult head, adult abdominal, and pediatric abdominal examinations were used to calculate volume CTDI (CTDI(vol)), and the average and standard deviation were calculated by year. Histogram analysis was performed to determine 75th and 90th percentiles of CTDI(vol). RESULTS: Between September 2002 and December 2004, 829 scanners underwent the accreditation process. Volume CTDI values (average ± SD) for 2002, 2003, 2004, and 2002 to 2004, respectively, were 66.7 ± 23.5, 58.5 ± 17.5, 55.8 ± 15.7, and 59.1 ± 18.6 mGy for adult head examinations; 18.7 ± 8.0, 19.2 ± 8.6, 17.0 ± 7.6, and 18.4 ± 8.3 for adult abdominal examinations; and 17.2 ± 9.7, 15.9 ± 8.6, 14.0 ± 7.0, and 15.5 ± 8.4 for pediatric abdominal examinations. For 2004 data, 23.8%, 2.3%, and 6.9% of sites reported doses above the 2002 CTDI(w) reference levels, compared with 49.6%, 4.7%, and 15% for 2002 data for adult head, adult abdominal, and pediatric abdominal examinations, respectively. Seventy-fifth percentiles of CTDI(vol) were 76.8 mGy (adult head, 2002 only), 22.2 mGy (adult abdominal), and 20.0 mGy (pediatric abdominal). CONCLUSIONS: From 2002 to 2004, average CTDI(vol) values decreased by 10.9, 1.7, and 3.2 mGy for adult head, adult abdominal, and pediatric abdominal examinations. Effective January 1, 2008, the ACR program implemented United States-specific diagnostic reference levels of 75, 25, and 20 mGy, respectively, for the CTDI(vol) of routine adult head, adult abdominal, and pediatric abdominal CT scans.


Assuntos
Acreditação/organização & administração , Doses de Radiação , Proteção Radiológica/normas , Radiometria/normas , Abdome/efeitos da radiação , Adulto , Fatores Etários , Criança , Pré-Escolar , Estudos de Avaliação como Assunto , Feminino , Cabeça/diagnóstico por imagem , Humanos , Masculino , Avaliação de Programas e Projetos de Saúde , Radiografia Abdominal/normas , Valores de Referência , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Gestão da Segurança , Sociedades Médicas/normas , Estados Unidos
2.
J Am Coll Radiol ; 8(4): 275-80, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21458767

RESUMO

PURPOSE: The aim of this study was to determine, for 3 basic clinical examinations, whether blinded, experienced CT radiologists participating in the ACR's CT Accreditation Program could use scan parameters such as tube current-time product (mAs), tube voltage (kVp), and pitch to predict scanner output settings, expressed as weighted CT dose index (CTDIw) and volume CT dose index (CTDIvol), exceeding CTDIw diagnostic reference levels (DRLs) set by the ACR in 2002 and CTDIvol DRLs adopted by the ACR in 2008. METHODS: CT sites with 829 scanners submitted examinations to the ACR between 2002 and 2004, yielding 518 eligible examinations for analysis (138 adult head CT scans, 333 adult abdominal CT scans, and 47 pediatric abdominal CT scans). The sites' measured CTDIw values for each type of examination were compared with the ACR's CTDIw DRLs in effect from 2002 to 2004 and compared with comments regarding excessively high mAs or kVp made by radiologist clinical reviewers to determine if excessively high-dose index measurements could be predicted. The same analysis was repeated using CTDIvol DRLs adopted by the ACR in 2008 and compared with excessively high mAs or kVp and excessively low-pitch comments. RESULTS: Excessively high mAs or kVp comments yielded sensitivity of only 21.2% in predicting examinations above the CTDIw DRLs, with specificity of 87.6%. Using the 2008 CTDIvol DRLs, the corresponding sensitivity was 13.1% and specificity was 86.2%. Significance was not achieved for use of clinical parameters in predicting either the CTDIw or CTDIvol. CONCLUSION: Experienced CT radiologists cannot reliably use scan parameters to predict examinations that exceed CTDIw or CTDIvol DRLs.


Assuntos
Acreditação , Competência Clínica , Avaliação Educacional/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/normas , Bases de Dados Factuais , Humanos , Valor Preditivo dos Testes , Sociedades Médicas , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...