1.
Bone Joint J ; 98-B(11): 1455-1462, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27803220

RESUMO

AIMS: We investigated whether blood metal ion levels could effectively identify patients with bilateral Birmingham Hip Resurfacing (BHR) implants who have adverse reactions to metal debris (ARMD). PATIENTS AND METHODS: Metal ion levels in whole blood were measured in 185 patients with bilateral BHRs. Patients were divided into those with ARMD who either had undergone a revision for ARMD or had ARMD on imaging (n = 30), and those without ARMD (n = 155). Receiver operating characteristic analysis was used to determine the optimal thresholds of blood metal ion levels for identifying patients with ARMD. RESULTS: The maximum level of cobalt or chromium ions in the blood was the parameter which produced the highest area under the curve (91.0%). The optimal threshold for distinguishing between patients with and without ARMD was 5.5 µg/l (83.3% sensitivity, 88.4% specificity, 58.1% positive and 96.5% negative predictive values). Similar results were obtained in a subgroup of 111 patients who all underwent cross-sectional imaging. Between 3.2% and 4.3% of patients with ARMD were missed if United Kingdom (7 µg/l) and United States (10 µg/l) authority thresholds were used respectively, compared with 2.7% if our implant specific threshold was used, though these differences did not reach statistical significance (p ≥ 0.248). CONCLUSION: Patients with bilateral BHRs who have blood metal ion levels below our implant specific threshold were at low-risk of having ARMD. Cite this article: Bone Joint J 2016;98-B:1455-62.


Assuntos
Artroplastia de Quadril/efeitos adversos , Cromo/sangue , Cobalto/sangue , Corpos Estranhos/sangue , Prótese de Quadril/efeitos adversos , Próteses Articulares Metal-Metal/efeitos adversos , Adulto , Idoso , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Biomarcadores/sangue , Feminino , Corpos Estranhos/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese/etiologia , Curva ROC , Reoperação , Sensibilidade e Especificidade
2.
Ann R Coll Surg Engl ; 98(2): 143-9, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26741659

RESUMO

INTRODUCTION: We assessed changes in metal-on-metal hip arthroplasties (MoMHAs) after repeat ultrasound examination. METHODS: This retrospective, single-centre cohort study involved all patients undergoing two ultrasound examinations of the same MoMHA. Between 2010 and 2014, 96 ultrasound examinations were performed in 48 MoMHAs (mean time between scans = 1.1 years). A radiologist assigned each scan to one of four grades and measured volumes of any solid/cystic masses. Changes in grade and lesion volume between scans were analysed. RESULTS: Change in grade between scans was significant (p=0.012); 27% (n=13) of MoMHAs increased in grade, 67% (n=32) had no grade change, and 6% (n=3) decreased in grade. The mean increase in lesion volume was 24.2cm(3) by the second scan, and was significant (p=0.023). Evidence of progression in findings was observed in 54% (26/48) of MoMHAs. Of patients with normal scans initially, 44% (8/18) developed abnormalities. No factors (including blood metal ion concentrations and cup position) were associated significantly with progression of ultrasound findings. CONCLUSIONS: Repeat ultrasound in MoMHA patients demonstrated that findings frequently progress in the short-term. Therefore, regular surveillance of MoMHA patients is important, with ultrasound representing an effective investigation for identifying the development and progression of lesions.


Assuntos
Análise de Falha de Equipamento/métodos , Prótese de Quadril/efeitos adversos , Quadril/diagnóstico por imagem , Próteses Articulares Metal-Metal/efeitos adversos , Complicações Pós-Operatórias/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Feminino , Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Estudos Retrospectivos , Ultrassonografia