Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Langmuir ; 40(11): 5606-5616, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38501265

RESUMO

The motion of partly gold (Au)-coated Janus particles under laser irradiation is caused by self-thermophoresis. Despite numerous studies addressing this topic, the impact of the preparation method and the degree of coverage of the particle with Au on the resulting thermophoretic velocity has not yet been fully understood. A detailed understanding of the most important tuning parameters during the preparation process is crucial to design Janus particles that are optimized for Au coverage to receive a high thermophoretic velocity. In this study, we explore the influence of the fabrication process, which changes the Au cap size, on the resulting self-propulsion behavior of partly Au-coated polystyrene particles (Au-PS). Additionally, the impact of an underlying adhesion chromium layer is investigated. In addition to the most commonly used qualitative SEM and EDX measurements, we propose a novel and fast technique utilizing AFM studies to quantify the cap size. This non-invasive technique can be used to determine both the size and the maximum thickness of the Au cap. The Au cap size was systematically varied in a range between about 36 and 74% by different preparation strategies. Nevertheless, we showed that the differing Au cap sizes of the Janus particles in this range have no obvious effect on the thermophoretic velocity. This is a surprising result since one would expect an effect of the Au cap size due to different solvent flows around the Janus particles and is attributed to an additional torque near the surface of the measuring cell.

2.
J Endovasc Ther ; : 15266028241230943, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38380529

RESUMO

PURPOSE: The aim of this study was to evaluate the radiation dose, image quality, and the potential of virtual monoenergetic imaging (VMI) reconstructions of high-pitch computed tomography angiography (CTA) of the thoracoabdominal aorta on a dual-source photon-counting detector-CT (PCD-CT) in comparison with an energy-integrating detector-CT (EID-CT), with a special focus on low-contrast attenuation. METHODS: Consecutive patients being referred for an electrocardiogram (ECG)-gated, high-pitch CTA of the thoracoabdominal aorta prior to transcatheter aortic valve replacement (TAVR), and examined on the PCD-CT, were included in this prospective single-center study. For comparison, a retrospective patient group with ECG-gated, high-pitch CTA examinations of the thoracoabdominal aorta on EID-CT with a comparable scan protocol was matched for gender, body mass index, height, and age. Virtual monoenergetic imaging reconstructions from 40 to 120 keV were performed. Enhancement and noise were measured in 7 vascular segments and the surrounding air as mean and standard deviation of CT values. The radiation dose was noted and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Finally, a subgroup analysis was performed, comparing VMI reconstructions from 40 keV to 70 keV in patients with at least a 50% decrease in contrast attenuation between the ascending aorta and femoral arteries. RESULTS: Fifty patients (mean age 77.0±14.5 years; 31 women) were included. The radiation dose was significantly lower on the PCD-CT (4.2±1.4 vs. 7.2±2.2 mGy; p<0.001). With increasing keV, vascular noise, SNR, and CNR decreased. Intravascular attenuation was significantly higher on VMI at levels from 40 to 65, compared with levels of 120 keV (p<0.01 and p<0.005, respectively). On the PCD-CT, SNR was significantly higher in keV levels 40 and 70 (all p<0.001), and CNR was higher at keV levels 40 and 45 (each p<0.001), compared with scans on the EID-CT. At VMI ≤60 keV, image noise was also significantly higher than that in the control group. The subgroup analysis showed a drastically improved diagnostic performance of the low-keV images in patients with low-contrast attenuation. CONCLUSION: The ECG-gated CTA of the thoracoabdominal aorta in high-pitch mode on PCD-CT have significantly lower radiation dose and higher objective image quality than EID-CT. In addition, low-keV VMI can salvage suboptimal contrast studies, further reducing radiation dose by eliminating the need for repeat scans. CLINICAL IMPACT: ECG-gated CT-angiographies of the thoracoabdominal aorta can be acquired with a lower radtiation dose and a better image quality by using a dual-source photon-countinge detector CT. Furthermore, the inherent spectral data offers the possiblity to improve undiagnostic images and thus saves the patient from further radiation and contrast application.

3.
Int J Cardiovasc Imaging ; 40(4): 723-732, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38175389

RESUMO

The aim of our study was to evaluate two different virtual non-contrast (VNC) algorithms applied to photon counting detector (PCD)-CT data in terms of noise, effectiveness of contrast media subtraction and aortic valve calcium (AVC) scoring compared to reference true non-contrast (TNC)-based results. Consecutive patients underwent TAVR planning examination comprising a TNC scan, followed by a CTA of the heart. VNC series were reconstructed using a conventional (VNCconv) and a calcium-preserving (VNCpc) algorithm. Noise was analyzed by means of the standard deviation of CT-values within the left ventricle. To assess the effectiveness of contrast media removal, heart volumes were segmented and the proportion of their histograms > 130HU was taken. AVC was measured by Agatston and volume score. 41 patients were included. Comparable noise levels to TNC were achieved with all VNC reconstructions. Contrast media was effectively virtually removed (proportions > 130HU from 81% to < 1%). Median calcium scores derived from VNCconv underestimated TNC-based scores (up to 74%). Results with smallest absolute difference to TNC were obtained with VNCpc reconstructions (0.4 mm, Br36, QIR 4), but with persistent significant underestimation (median 29%). Both VNC algorithms showed near-perfect (r²>0.9) correlation with TNC. Thin-slice VNC reconstructions provide equivalent noise levels to standard thick-slice TNC series and effective virtual removal of iodinated contrast. AVC scoring was feasible on both VNC series, showing near-perfect correlation, but with significant underestimation. VNCpc with 0.4 mm slices and Br36 kernel at QIR 4 gave the most comparable results and, with further advances, could be a promising replacement for additional TNC.


Assuntos
Algoritmos , Estenose da Valva Aórtica , Valva Aórtica , Valva Aórtica/patologia , Calcinose , Angiografia por Tomografia Computadorizada , Tomografia Computadorizada Multidetectores , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Feminino , Idoso , Masculino , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Reprodutibilidade dos Testes , Substituição da Valva Aórtica Transcateter/instrumentação , Calcinose/diagnóstico por imagem , Meios de Contraste/administração & dosagem
4.
Diagnostics (Basel) ; 13(22)2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-37998539

RESUMO

In photon-counting detector CT (PCD-CT), coronary artery calcium scoring (CACS) can be performed using virtual non-contrast (VNC) series derived from coronary CT angiography (CCTA) datasets. Our study analyzed image characteristics of VNC series in terms of the efficacy of virtual iodine "removal" and image noise to determine whether the prerequisites for calcium quantification were satisfied. We analyzed 38 patients who had undergone non-enhanced CT followed by CCTA on a PCD-CT. VNC reconstructions were performed at different settings and algorithms (conventional VNCConv; PureCalcium VNCPC). Virtual iodine "removal" was investigated by comparing histograms of heart volumes. Noise was assessed within the left ventricular cavity. Calcium was quantified on the true non-contrast (TNC) and all VNC series. The histograms were comparable for TNC and all VNC. Image noise between TNC and all VNC differed slightly but significantly. VNCConv CACS showed a significant underestimation regardless of the reconstruction setting, while VNCPC CACS were comparable to TNC. Correlations between TNC and VNC were excellent, with a higher predictive accuracy for VNCPC. In conclusion, the iodine contrast can be effectively subtracted from CCTA datasets. The remaining VNC series satisfy the requirements for CACS, yielding results with excellent correlation compared to TNC-based CACS and high predicting accuracy.

5.
Eur J Radiol ; 166: 110967, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37487433

RESUMO

PURPOSE: To correlate CT values of the blood pool on VNC series with serum hemoglobin values for the detection of anemia in oncologic patients undergoing contrast-enhanced PCD-CT scans. METHODS: This prospective study (NCT04989192) included consecutive oncologic patients undergoing contrast-enhanced CT on a novel PCD-CT system between 08/2021 and 01/2022. The interval between complete blood count (CBC) and CT scan acquisition had to be no more than seven days. CT-values of the blood pool were measured on 70 keV VMI series (CT-values(BP)70keV) and on VNC series (CT-values(BP)VNC) at five anatomic positions (left atrium, left ventricle, main pulmonary artery, ascending and descending aorta) and averaged per patient. Pearson correlation analyses and ROC analyses were performed to identify relations between CT-values(BP)VNC, CBC parameters, and degrees of anemia as defined by the WHO (no anemia, mild, moderate, severe anemia). RESULTS: A total of 329 patients (age 68 ± 12 years; 200 men) were included. CT-values(BP)VNC showed a strong linear correlation to serum hemoglobin (r2 = 0.80, p <.001) and hematocrit (r2 = 0.76, p <.001) and were significantly different between anemia subgroups in both women and men (ΔHU: 3.5-11.4; all p <.01). ROC analyses yielded high diagnostic performance for the identification of patients without anemia, patients without and with mild anemia, and patients with severe anemia using gender-specific cutoffs for CT-value(BP)VNC (all AUC's > 0.90). CONCLUSIONS: The spectral information inherent in PCD-CT acquisitions allows the detection and quantification of anemia in contrast-enhanced CT acquisitions of oncologic patients with high diagnostic accuracy.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Hemoglobinas , Estudos Prospectivos , Curva ROC , Estudo de Prova de Conceito
6.
Eur J Radiol ; 165: 110946, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37399668

RESUMO

PURPOSE: To investigate the usefulness of virtual monoenergetic image (VMI) reconstructions derived from scans on a novel photon-counting detector CT (PCD-CT) for artifact reduction in patients after posterior spinal fixation. METHODS: This retrospective cohort study included 23 patients status post posterior spinal fixation. Subjects were scanned on a novel PCD-CT (NAEOTOM Alpha, Siemens Healthineers, Erlangen, Germany) as part of routine clinical care. 14 sets of VMI reconstructions were derived in 10 keV increments for the interval 60-190 keV. The mean and the standard deviation (SD) of CT-values in 12 defined locations around a pair of pedicle screws on one vertebral level and the SD of homogenous fat were measured and used to calculate an artifact index (AIx). RESULTS: Averaged over all regions, the lowest AIx was observed at VMI levels of 110 keV (32.5 (27.8-37.9)) which was significantly different from those of VMIs ≤ 90 keV (p < 0.001) or ≥160 keV (p < 0.015), respectively. Overall AIx values increased in both lower- and higher-keV levels. Regarding individual locations, either a monotonous AIx-decrease for increasing keV values or an AIx-minimum in intermediate-keV levels (100-140 keV) was found. In locations adjacent to larger metal parts, the increase of AIx values at the high-end of the keV spectrum was mainly explained by a reappearance of streak artifacts. CONCLUSION: Our findings suggest that 110 keV is the optimal VMI setting for overall artifact suppression. In specific anatomical regions, however, slight adjustments towards higher-keV levels may provide better results.


Assuntos
Artefatos , Tomografia Computadorizada por Raios X , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/cirurgia , Metais , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Razão Sinal-Ruído
7.
Invest Radiol ; 58(9): 691-696, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-36897803

RESUMO

OBJECTIVE: The aim of this study was to compare the effectiveness of common strategies for artifact reduction of dental material in photon-counting detector computed tomography data sets. MATERIALS AND METHODS: Patients with dental material who underwent clinically indicated CT of the neck were enrolled. Image series were reconstructed using a standard and sharp kernel, with and without iterative metal artifact reduction (IMAR) (Qr40, Qr40 IMAR , Qr60, Qr60 IMAR ) at different virtual monoenergetic imaging (VMI) levels (40-190 keV). On representative slice positions with and without dental artifacts, mean and standard deviation of CT values were measured in all series at identical locations. The mean absolute error of CT values ( ) and the artifact index (AIX) were calculated and analyzed focusing on 3 main comparisons: ( a ) different VMI levels versus 70 keV, ( b ) standard versus sharp kernel, and ( c ) nonuse or use of IMAR reconstruction. The Wilcoxon test was used to assess differences for nonparametric data. RESULTS: The final cohort comprised 50 patients. Artifact measures decreased for VMI levels >70 keV, yet only significantly so for reconstructions using IMAR (maximum reduction, 25%). The higher image noise of the sharp versus standard kernel is reflected in higher AIX values and is more pronounced in IMAR series (maximum increase, 38%). The most profound artifact reduction was observed for IMAR reconstructions (maximum reduction : 84%; AIX: 90%). CONCLUSIONS: Metal artifacts caused by large amounts of dental material can be substantially reduced by IMAR, regardless of kernel choice or VMI settings. Increasing the keV level of VMI series, on the other hand, only slightly reduces dental artifacts; this effect, however, is additive to the benefit conferred by IMAR reconstructions.


Assuntos
Artefatos , Metais , Humanos , Tomografia Computadorizada por Raios X/métodos , Pescoço , Materiais Dentários , Algoritmos
8.
Neuromodulation ; 26(2): 280-291, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35970765

RESUMO

OBJECTIVES: The aim of this study was to identify and systematically analyze relevant literature on surgical site infections (SSIs) associated with implantable pulse generator (IPG) procedures for deep brain stimulation (DBS). MATERIALS AND METHODS: In compliance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, we conducted a systematic review and meta-analyses of 58 studies that reported SSI rates of 11,289 patients and 15,956 IPG procedures. A meta-analysis of proportions was performed to estimate the pooled proportion of SSIs across DBS procedures in general and to estimate the proportion of SSIs that occur at the IPG pocket. Moreover, a meta-analysis of odds ratio (OR) was conducted on those studies that reported their results of applying topical vancomycin powder during closure of the IPG wound. Results are presented as rates and OR with 95% CIs. RESULTS: The pooled proportion of SSIs was 4.9% (95% CI, 4.1%-6.1%) among all DBS procedures. The dominant SSI localization was the IPG pocket in 61.2% (95% CI, 53.4%-68.5%). A trend toward a beneficial effect of vancomycin powder over standard wound closure was found with an OR of 0.46 (95% CI, 0.21-1.02). Most studies (79.1%) that reported their treatment strategy in case of SSI had a strict protocol of removal of the IPG, followed by antimicrobial treatment and reimplantation of the IPG once the SSI had been eradicated. CONCLUSIONS: The IPG pocket was identified as the main site of SSI after DBS procedures. Most studies recommend complete IPG removal, antimicrobial treatment, and reimplantation of an IPG once the SSI has been eradicated. Future studies are needed to clarify the role of alternative approaches (eg, topical vancomycin powder) in the prevention of SSI associated with IPG.


Assuntos
Anti-Infecciosos , Estimulação Encefálica Profunda , Humanos , Antibacterianos/uso terapêutico , Estimulação Encefálica Profunda/efeitos adversos , Pós , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/etiologia , Infecção da Ferida Cirúrgica/prevenção & controle , Vancomicina/uso terapêutico
9.
Eur Radiol ; 33(4): 2450-2460, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36462042

RESUMO

OBJECTIVES: To assess epicardial adipose tissue (EAT) volume and attenuation of different virtual non-contrast (VNC) reconstructions derived from coronary CTA (CCTA) datasets of a photon-counting detector (PCD) CT-system to replace true non-contrast (TNC) series. METHODS: Consecutive patients (n = 42) with clinically indicated CCTA and coronary TNC were included. Two VNC series were reconstructed, using a conventional (VNCConv) and a novel calcium-preserving (VNCPC) algorithm. EAT was segmented on TNC, VNCConv, VNCPC, and CCTA (CTA-30) series using thresholds of -190 to -30 HU and an additional segmentation on the CCTA series with an upper threshold of 0 HU (CTA0). EAT volumes and their histograms were assessed for each series. Linear regression was used to correlate EAT volumes and the Euclidian distance for histograms. The paired t-test and the Wilcoxon signed-rank test were used to assess differences for parametric and non-parametric data. RESULTS: EAT volumes from VNC and CCTA series showed significant differences compared to TNC (all p < .05), but excellent correlation (all R2 > 0.9). Measurements on the novel VNCPC series showed the best correlation (R2 = 0.99) and only minor absolute differences compared to TNC values. Mean volume differences were -12%, -3%, -13%, and +10% for VNCConv, VNCPC, CTA-30, and CTA0 compared to TNC. Distribution of CT values on VNCPC showed less difference to TNC than on VNCConv (mean attenuation difference +7% vs. +2%; Euclidean distance of histograms 0.029 vs. 0.016). CONCLUSIONS: VNCPC-reconstructions of PCD-CCTA datasets can be used to reliably assess EAT volume with a high accuracy and only minor differences in CT values compared to TNC. Substitution of TNC would significantly decrease patient's radiation dose. KEY POINTS: • Measurement of epicardial adipose tissue (EAT) volume and attenuation are feasible on virtual non-contrast (VNC) series with excellent correlation to true non-contrast series (all R2>0.9). • Differences in VNC algorithms have a significant impact on EAT volume and CT attenuation values. • A novel VNC algorithm (VNCPC) enables reliable assessment of EAT volume and attenuation with superior accuracy compared to measurements on conventional VNC- and CCTA-series.


Assuntos
Angiografia , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Reprodutibilidade dos Testes , Fótons , Tecido Adiposo/diagnóstico por imagem , Estudos Retrospectivos
11.
Sci Adv ; 8(23): eabm2456, 2022 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-35687679

RESUMO

Advances in imaging techniques enable high-resolution three-dimensional (3D) visualization of vascular networks over time and reveal abnormal structural features such as twists and loops, and their quantification is an active area of research. Here, we showcase how topological data analysis, the mathematical field that studies the "shape" of data, can characterize the geometric, spatial, and temporal organization of vascular networks. We propose two topological lenses to study vasculature, which capture inherent multiscale features and vessel connectivity, and surpass the single-scale analysis of existing methods. We analyze images collected using intravital and ultramicroscopy modalities and quantify spatiotemporal variation of twists, loops, and avascular regions (voids) in 3D vascular networks. This topological approach validates and quantifies known qualitative trends such as dynamic changes in tortuosity and loops in response to antibodies that modulate vessel sprouting; furthermore, it quantifies the effect of radiotherapy on vessel architecture.

12.
Diagnostics (Basel) ; 12(5)2022 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-35626387

RESUMO

In dual-energy CT datasets, the conspicuity of liver metastases can be enhanced by virtual monoenergetic imaging (VMI) reconstructions at low keV levels. Our study investigated whether this effect can be reproduced in photon-counting detector CT (PCD-CT) datasets. We analyzed 100 patients with liver metastases who had undergone contrast-enhanced CT of the abdomen on a PCD-CT (n = 50) or energy-integrating detector CT (EID-CT, single-energy mode, n = 50). PCD-VMI-reconstructions were performed at various keV levels. Identical regions of interest were positioned in metastases, normal liver, and other defined locations assessing image noise, tumor-to-liver ratio (TLR), and contrast-to-noise ratio (CNR). Patients were compared inter-individually. Subgroup analyses were performed according to BMI. On the PCD-CT, noise and CNR peaked at the low end of the keV spectrum. In comparison with the EID-CT, PCD-VMI-reconstructions exhibited lower image noise (at 70 keV) but higher CNR (for ≤70 keV), despite similar CTDIs. Comparing high- and low-BMI patients, CTDI-upregulation was more modest for the PCD-CT but still resulted in similar noise levels and preserved CNR, unlike the EID-CT. In conclusion, PCD-CT VMIs in oncologic patients demonstrated reduced image noise-compared to a standard EID-CT-and improved conspicuity of hypovascularized liver metastases at low keV values. Patients with higher BMIs especially benefited from constant image noise and preservation of lesion conspicuity, despite a more moderate upregulation of CTDI.

13.
Invest Radiol ; 57(8): 536-543, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35318969

RESUMO

PURPOSE: The aim of this study was to evaluate coronary computed tomography angiography (CCTA)-based in vitro and in vivo coronary artery calcium scoring (CACS) using a novel virtual noniodine reconstruction (PureCalcium) on a clinical first-generation photon-counting detector-computed tomography system compared with virtual noncontrast (VNC) reconstructions and true noncontrast (TNC) acquisitions. MATERIALS AND METHODS: Although CACS and CCTA are well-established techniques for the assessment of coronary artery disease, they are complementary acquisitions, translating into increased scan time and patient radiation dose. Hence, accurate CACS derived from a single CCTA acquisition would be highly desirable. In this study, CACS based on PureCalcium, VNC, and TNC, reconstructions was evaluated in a CACS phantom and in 67 patients (70 [59/80] years, 58.2% male) undergoing CCTA on a first-generation photon counting detector-computed tomography system. Coronary artery calcium scores were quantified for the 3 reconstructions and compared using Wilcoxon test. Agreement was evaluated by Pearson and Spearman correlation and Bland-Altman analysis. Classification of coronary artery calcium score categories (0, 1-10, 11-100, 101-400, and >400) was compared using Cohen κ . RESULTS: Phantom studies demonstrated strong agreement between CACS PureCalcium and CACS TNC (60.7 ± 90.6 vs 67.3 ± 88.3, P = 0.01, r = 0.98, intraclass correlation [ICC] = 0.98; mean bias, 6.6; limits of agreement [LoA], -39.8/26.6), whereas CACS VNC showed a significant underestimation (42.4 ± 75.3 vs 67.3 ± 88.3, P < 0.001, r = 0.94, ICC = 0.89; mean bias, 24.9; LoA, -87.1/37.2). In vivo comparison confirmed a high correlation but revealed an underestimation of CACS PureCalcium (169.3 [0.7/969.4] vs 232.2 [26.5/1112.2], P < 0.001, r = 0.97, ICC = 0.98; mean bias, -113.5; LoA, -470.2/243.2). In comparison, CACS VNC showed a similarly high correlation, but a substantially larger underestimation (24.3 [0/272.3] vs 232.2 [26.5/1112.2], P < 0.001, r = 0.97, ICC = 0.54; mean bias, -551.6; LoA, -2037.5/934.4). CACS PureCalcium showed superior agreement of CACS classification ( κ = 0.88) than CACS VNC ( κ = 0.60). CONCLUSIONS: The accuracy of CACS quantification and classification based on PureCalcium reconstructions of CCTA outperforms CACS derived from VNC reconstructions.


Assuntos
Angiografia por Tomografia Computadorizada , Doença da Artéria Coronariana , Algoritmos , Cálcio , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Masculino , Tomografia Computadorizada por Raios X/métodos
14.
Diagnostics (Basel) ; 12(3)2022 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-35328111

RESUMO

The purpose of this study was to evaluate virtual-non contrast reconstructions of Photon-Counting Detector (PCD) CT-angiography datasets using a novel calcium-preserving algorithm (VNCPC) vs. the standard algorithm (VNCConv) for their potential to replace unenhanced acquisitions (TNC) in patients after endovascular aneurysm repair (EVAR). 20 EVAR patients who had undergone CTA (unenhanced and arterial phase) on a novel PCD-CT were included. VNCConv- and VNCPC-series were derived from CTA-datasets and intraluminal signal and noise compared. Three readers evaluated image quality, contrast removal, and removal of calcifications/stent parts and assessed all VNC-series for their suitability to replace TNC-series. Image noise was higher in VNC- than in TNC-series (18.6 ± 5.3 HU, 16.7 ± 7.1 HU, and 14.9 ± 7.1 HU for VNCConv-, VNCPC-, and TNC-series, p = 0.006). Subjective image quality was substantially higher in VNCPC- than VNCConv-series (4.2 ± 0.9 vs. 2.5 ± 0.6; p < 0.001). Aortic contrast removal was complete in all VNC-series. Unlike in VNCConv-reconstructions, only minuscule parts of stents or calcifications were erroneously subtracted in VNCPC-reconstructions. Readers considered 95% of VNCPC-series fully or mostly suited to replace TNC-series; for VNCConv-reconstructions, however, only 75% were considered mostly (and none fully) suited for TNC-replacement. VNCPC-reconstructions of PCD-CT-angiography datasets have excellent image quality with complete contrast removal and only minimal erroneous subtractions of stent parts/calcifications. They could replace TNC-series in almost all cases.

15.
Eur J Radiol ; 148: 110181, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35121331

RESUMO

PURPOSE: To analyze the quantitative and qualitative image quality of low-dose CT scans of the abdomen on a novel photon-counting detector CT (PCD-CT) in comparison with a traditional energy-integrating detector CT (EID-CT). METHODS: Consecutive patients with clinically indicated low-dose CT were scanned on a PCD-CT and compared with a BMI-matched EID-CT-cohort scanned during the same timeframe. Radiation dose, image noise, and signal-to-noise ratio (SNR) were measured for each patient. Furthermore, image quality and conspicuity of abdominal structures (adrenal glands, mesenteric vessels, ureters, and renal pelvis) were assessed on 5-point Likert-scales (1 = very poor quality/not detectable; 5 = excellent quality/differentiability). RESULTS: Twenty patients (mean age 46.2 [range: 19-77]; 13 men) were included. Image noise was significantly lower (24.9 ± 3.3 vs. 31.4 ± 5.6 SD HU, p < 0.001) and SNR significantly higher (2.1 ± 0.3 vs. 1.5 ± 0.4; p < 0.001) on the PCD-CT. Subjective image quality was substantially higher (4.0 ± 0.3 vs. 3.1 ± 0.6; p < 0.001) and conspicuity better for the renal pelvis, ureters, and mesenteric vessels on the PCD-CT. There was no significant difference in the conspicuity of the adrenal glands. With increasing BMI (1st-4th BMI quartile), noise increased, and SNR decreased more strongly on the EID-CT than on the PCD-CT (ΔNoise: 39% vs. 2%, ΔSNR: -33% vs. -7% for EID-CT vs. PCD-CT, respectively) while radiation dose increased comparably (70 vs. 59%). CONCLUSIONS: Low-dose CT scans of the abdomen performed on a novel PCD-CT exhibit reduced noise, higher SNR, increased subjective image quality, and superior conspicuity of abdominal fine structures compared to scans in comparable patients on an EID-CT.


Assuntos
Fótons , Tomografia Computadorizada por Raios X , Abdome/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Doses de Radiação , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos
16.
Eur Radiol ; 32(5): 2930-2936, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34936011

RESUMO

OBJECTIVES: Photon-counting detector CT (PCD-CT) promises a leap in spatial resolution due to smaller detector pixel sizes than implemented in energy-integrating detector CTs (EID-CT). Our objective was to compare the visualization of smallest bone details between PCD-CT and EID-CT using a mouse as a specimen. MATERIALS AND METHODS: Two euthanized mice were scanned at a 20-slice EID-CT and a dual-source PCD-CT in single-pixel mode at various CTDIVol values. Image noise and signal-to-noise ratio (SNR) were evaluated using repeated ROI measurements. Edge sharpness of bones was compared by the maximal slope within CT value plots along sampling lines intersecting predefined bones of the spine. Two readers evaluated bone detail visualization at four regions of the spine on a three-point Likert scale at various CTDIVol's. Two radiologists selected the series with better detail visualization among each of 20 SNR-matched pairs of EID-CT and PCD-CT series. RESULTS: In CTDIVol-matched scans, PCD-CT series showed significantly lower image noise (NoiseCTDI=5 mGy: 16.27 ± 1.39 vs. 23.46 ± 0.96 HU, p < 0.01), higher SNR (SNRCTDI=5 mGy: 20.57 ± 1.89 vs. 14.00 ± 0.66, p < 0.01), and higher edge sharpness (Edge Slopelumbar spine: 981 ± 160 vs. 608 ± 146 HU/mm, p < 0.01) than EID-CT series. Two radiologists considered the delineation of bone details as feasible at consistently lower CTDIVol values at PCD-CT than at EID-CT. In comparison of SNR-matched reconstructions, PCD-CT series were still considered superior in almost all cases. CONCLUSIONS: In this head-to-head comparison, PCD-CT showed superior objective and subjective image quality characteristics over EID-CT for the delineation of tiniest bone details. Even in SNR-matched pairs (acquired at different CTDIVol's), PCD-CT was strongly preferred by radiologists. KEY POINTS: • In dose-matched scans, photon-counting detector CT series showed significantly less image noise, higher signal-to-noise ratio, and higher edge sharpness than energy-integrating detector CT series. • Human observers considered the delineation of tiny bone details as feasible at much lower dose levels in photon-counting detector CT than in energy-integrating detector CT. • In direct comparison of series matched for signal-to-noise ratio, photon-counting detector CT series were considered superior in almost all cases.


Assuntos
Fótons , Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Razão Sinal-Ruído , Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/métodos
17.
Oncoimmunology ; 10(1): 1938475, 2021 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-34178430

RESUMO

The monoclonal antibody against CTLA-4, Ipilimumab, is a first-in-class immune-checkpoint inhibitor approved for treatment of advanced melanoma in adults but not extensively studied in children. In light of the fact that the immune response early in life differs from that of adults, we have applied a human in vitro model stimulating CD4+ T-cells from neonates, children (1-5 years), and adults antigen-specifically with Staphylococcus aureus (S. aureus) for assessment of CTLA-4 blockade early in life. We show that T-cell proliferation as well as frequencies of antigen-specific T-cells (CD40L+CD4+) were enhanced in neonatal T-cells upon CTLA-4 blockade showing a larger variance within the group (F-test p < .0001). Using machine learning algorithm Random Forest, adult and neonatal T-cell responses can be unambiguously categorized (F1 score-0.75) on the basis of their cytokine (co-)expression. Blockade of CTLA-4 enhanced frequencies of IL-8, IFNγ, and IL-10 producers among CD40L+ T-cells. Of note, antigen-specific T-cells from neonates displayed higher cytokine coproduction at baseline, while T-cells from children caught up to neonates, and adults to baseline of children upon CTLA-4 blockade. These findings reveal that in neonatal T-cells blockade of CTLA-4 mainly unleashes the antigen-specific capacity by increasing the numbers of responding T-cells, whereas in children and adults it promotes the coexpression of cytokines by individual T-cells. Thus, CTLA-4 blockade boosts antitumor immunity through different mechanisms depending on the patients' age. These data implicate a strong impact of the developmental stage of the T-cell compartment on the effects of immune-checkpoint therapy.


Assuntos
Antígeno CTLA-4/antagonistas & inibidores , Inibidores de Checkpoint Imunológico , Adulto , Pré-Escolar , Humanos , Imunoterapia , Lactente , Recém-Nascido , Staphylococcus aureus , Linfócitos T
18.
Sci Rep ; 10(1): 18624, 2020 10 29.
Artigo em Inglês | MEDLINE | ID: mdl-33122646

RESUMO

Digital pathology enables computational analysis algorithms to be applied at scale to histological images. An example is the identification of immune cells within solid tumours. Image analysis algorithms can extract precise cell locations from immunohistochemistry slides, but the resulting spatial coordinates, or point patterns, can be difficult to interpret. Since localisation of immune cells within tumours may reflect their functional status and correlates with patient prognosis, novel descriptors of their spatial distributions are of biological and clinical interest. A range of spatial statistics have been used to analyse such point patterns but, individually, these approaches only partially describe complex immune cell distributions. In this study, we apply three spatial statistics to locations of CD68+ macrophages within human head and neck tumours, and show that images grouped semi-quantitatively by a pathologist share similar statistics. We generate a synthetic dataset which emulates human samples and use it to demonstrate that combining multiple spatial statistics with a maximum likelihood approach better predicts human classifications than any single statistic. We can also estimate the error associated with our classifications. Importantly, this methodology is adaptable and can be extended to other histological investigations or applied to point patterns outside of histology.


Assuntos
Neoplasias de Cabeça e Pescoço/imunologia , Neoplasias de Cabeça e Pescoço/patologia , Macrófagos/imunologia , Carcinoma de Células Escamosas de Cabeça e Pescoço/imunologia , Carcinoma de Células Escamosas de Cabeça e Pescoço/patologia , Algoritmos , Antígenos CD , Antígenos de Diferenciação Mielomonocítica , Estudos de Coortes , Humanos , Funções Verossimilhança
19.
Int J Comput Assist Radiol Surg ; 13(12): 1971-1980, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30039247

RESUMO

PURPOSE: To investigate whether structured reports (SRs) provide benefits regarding the completeness and the clarity of reports, as well as regarding the satisfaction of the referring physicians compared to narrative freetext reports (NRs) of MRI examinations of the petrous bone. METHODS: After sample size calculation, 32 patients with clinically indicated MRI examinations of the petrous bone were included in this retrospective study. The already existing NRs were taken from the radiologic information system. The corresponding SRs were retrospectively generated by two radiologists using an online-based application. All 64 reports (one NR and one SR per patient) were evaluated by two head and neck physicians using a questionnaire. RESULTS: While 41% of the SRs showed no missing report key feature, all NRs exhibited at least one missing key feature (p < 0.001). SRs achieved significantly higher satisfaction rates regarding the linguistic quality and overall report quality compared to NRs: Using a 6-point Likert scale (1 = insufficient to 6 = excellent), SRs were rated with a median value of 6 [interquartile range (IQR): 1] for linguistic as well as overall quality, and NRs were rated with a median of 5 (IQR: 0) for linguistic as well as overall quality (p < 0.001). CONCLUSIONS: Structured reporting of petrous bone MRI examinations may positively influence the completeness and quality of radiologic reports. Due to the easier readability and facilitation of information extraction, SRs improve the satisfaction level of the referring physicians.


Assuntos
Doenças Ósseas/diagnóstico , Imageamento por Ressonância Magnética/normas , Osso Petroso/diagnóstico por imagem , Sistemas de Informação em Radiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Inquéritos e Questionários , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...