Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Lab Med ; 54(4): 388-391, 2023 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-36493367

RESUMO

OBJECTIVE: Patients and physicians are increasingly requesting their clinical laboratory to provide SARS-CoV-2 serology interpretation. Our study aimed to assess the evolution of SARS-CoV-2 antibodies in Moderna-vaccinated health care workers. METHODS: We analyzed the evolution of mRNA-1273 (Moderna)-elicited antibodies by 2 high-throughput assays, TrimericS IgG (Diasorin) and SARS-CoV-2 IgG-II (Abbott). RESULTS: After the first injection, the COVID-19-recovered vaccinees showed a serological response as strong as that observed 1 month after the second injection in participants without COVID-19 history. Although remaining above the positivity thresholds, the TrimericS immunoglobulin G (IgG) and anti-RBD (receptor-binding domain) IgG levels fell considerably between 1 and 7 months postvaccination, dropping to 10.6% and 13% for the COVID-19 recovered subgroup and to 11.7% and 9.3% for the COVID-19 naive subgroup. CONCLUSION: Regardless of the test used, a decrease in circulating anti-SARS-CoV-2 IgG levels should be expected a few months after vaccination. As this decline does not preclude the efficacy of immune response, caution is necessary when interpretating postvaccination serological data.


Assuntos
Vacina de mRNA-1273 contra 2019-nCoV , COVID-19 , Humanos , Vacinas contra COVID-19 , COVID-19/diagnóstico , COVID-19/prevenção & controle , SARS-CoV-2/genética , Anticorpos Antivirais , Imunoglobulina G
2.
J Thromb Thrombolysis ; 53(1): 58-66, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34173169

RESUMO

The optimal thromboprophylactic strategy for patients affected by Coronavirus disease 2019 (COVID-19) has been debated among experts. This study evaluated the safety and efficacy of a thromboprophylaxis algorithm. This was a retrospective, single-center study in critically ill patients admitted to the intensive care unit (University affiliated Hospital) for acute respiratory failure due to Severe Acute Respiratory Syndrome-Coronavirus 2 (SARS-CoV-2). From March 16 to April 9, 2020, thromboprophylaxis was adjusted according to weight (control group, n = 19) and after this date, thromboprophylaxis depended on an algorithm based on thrombotic and hemorrhagic risk factors (protocol group, n = 13). With regard to safety (number of major bleeding events and blood transfusions), the groups were not significantly different. With regard to efficacy, the number of thrombotic events decreased from 37 to 0%, p = 0.025 after implementation of the algorithm. Also, peak fibrinogen dropped from 8.6 (7.2-9.3) to 6.5 (4.6-8.4) g/L, p = 0.041 and D-dimers from 2194 (1464-3763) to 1486 (900-2582) ng/mL, p = 0.0001. In addition, length of stay declined from 19 (10-31) to 5 (3-19) days, p = 0.009. In conclusion, a tailored thromboprophylaxis algorithm (risk stratification based on clinical parameters and biological markers) reduce thrombotic phenomena in critically ill COVID-19 patients without increasing major bleeding.


Assuntos
Algoritmos , Anticoagulantes/uso terapêutico , COVID-19 , Trombose , COVID-19/complicações , Estado Terminal , Hemorragia/induzido quimicamente , Humanos , Estudos Retrospectivos , Trombose/etiologia , Trombose/prevenção & controle
3.
Diagn Microbiol Infect Dis ; 102(2): 115561, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34773801

RESUMO

We report on sample IS/17575 since it generated highly divergent results in the Belgian SARS-CoV-2 serology external quality assessment scheme. Sample IS/17575 was serum originating from a 30 years old male patient. 124 diagnostic laboratories analysed this sample. A total of 168 results was returned (including 5 doubles). Overall, 38 were positive. All tests against S1 were positive except the Euroimmun IgG ELISA and the Ortho clinical Diagnostics VITROS IgG CLIA. All tests against S1/S2 (Liaison, Diasorin) resulted in a signal above cutoff. Assays against RBD, mostly generate a negative result. An exception are the Wantai SARS-CoV-2 ELISA's. All tests targeting N protein were negative. The survey shows, when >6 months post-infection, assays targeting at least S1, and preferably S1 combined with S2, are the most sensitive. This finding accentuates the necessity of external quality assessment schedules and importance of antigenic composition of serologic SARS-CoV-2 assays.


Assuntos
Antígenos Virais/imunologia , Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , Proteínas do Nucleocapsídeo de Coronavírus/imunologia , SARS-CoV-2/imunologia , Glicoproteína da Espícula de Coronavírus/imunologia , Adulto , Anticorpos Antivirais/imunologia , Bélgica , Testes Diagnósticos de Rotina , Ensaio de Imunoadsorção Enzimática , Humanos , Imunoglobulina A/imunologia , Imunoglobulina G/imunologia , Imunoglobulina M/imunologia , Masculino , Fosfoproteínas/imunologia , Sensibilidade e Especificidade
4.
Clin Chem Lab Med ; 59(5): 971-978, 2021 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-33554567

RESUMO

OBJECTIVES: Accurate SARS-CoV-2 serological assays are urgently needed to help diagnose infection, determine past exposure of populations and assess the response to future vaccines. The study aims at assessing the performance of the multiplex D-tek COVIDOT 5 IgG assay for the detection of SARS-CoV-2 IgG antibodies (N, S1+S2, S1, S2 and RBD). METHODS: Sensitivity and dynamic trend to seropositivity were evaluated in 218 samples obtained from 46 rRT-PCR confirmed COVID-19 patients. Non-SARS-CoV-2 sera (n=118) collected before the COVID-19 pandemic with a potential cross-reaction to the SARS-CoV-2 immunoassay were included in the specificity analysis. RESULTS: A gradual dynamic trend since symptom onset was observed for all IgG antibodies. Sensitivities before day 14 were suboptimal. At ≥21 days, sensitivities reached 100% (93.4-100%) for N, S1+S2, S2 and RBD-directed IgG and 96.3% (87.3-99.6%) for S1-directed IgG. In 42 out of 46 patients (91.3%), all five antibodies were detected at ≥14 days. The four remaining patients had between 2 and 4 positive antibodies at their respective maximal follow-up period. The specificity was 100 % for S1+S2, S2 and RBD, 98.3% for N and 92.4% (86.0-96.5%) for S1-directed IgG. The combined use of antigens increases the early sensitivity whilst enforcing high specificity. CONCLUSIONS: Sensitivities at ≥21 days and specificities were excellent, especially for N, S1+S2, S2 and RBD-directed IgG. Caution is however required when interpreting single S1-directed reactivities. Using a multiplex assay complies with the orthogonal testing algorithm of the CDC and allows a better and critical interpretation of the serological status of a patient.


Assuntos
Anticorpos Antivirais/sangue , Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , Imunoensaio/métodos , Imunoglobulina G/sangue , SARS-CoV-2/imunologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticorpos Antivirais/imunologia , COVID-19/sangue , Feminino , Humanos , Imunoglobulina G/imunologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
6.
Mol Microbiol ; 97(3): 397-407, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25899052

RESUMO

Human apolipoprotein L1 (APOL1) kills African trypanosomes except Trypanosoma rhodesiense and Trypanosoma gambiense, the parasites causing sleeping sickness. APOL1 uptake into trypanosomes is favoured by its association with the haptoglobin-related protein-haemoglobin complex, which binds to the parasite surface receptor for haptoglobin-haemoglobin. As haptoglobin-haemoglobin can saturate the receptor, APOL1 uptake is increased in haptoglobin-poor (hypohaptoglobinaemic) serum (HyHS). While T. rhodesiense resists APOL1 by RNA polymerase I (pol-I)-mediated expression of the serum resistance-associated (SRA) protein, T. gambiense resists by pol-II-mediated expression of the T. gambiense-specific glycoprotein (TgsGP). Moreover, in T. gambiense resistance to HyHS is linked to haptoglobin-haemoglobin receptor inactivation by mutation. We report that unlike T. gambiense, T. rhodesiense possesses a functional haptoglobin-haemoglobin receptor, and that like T. gambiense experimentally provided with active receptor, this parasite is killed in HyHS because of receptor-mediated APOL1 uptake. However, T. rhodesiense could adapt to low haptoglobin by increasing transcription of SRA. When assayed in Trypanosoma brucei, resistance to HyHS occurred with pol-I-, but not with pol-II-mediated SRA expression. Similarly, T. gambiense provided with active receptor acquired resistance to HyHS only when TgsGP was moved to a pol-I locus. Thus, transcription by pol-I favours adaptive gene regulation, explaining the presence of SRA in a pol-I locus.


Assuntos
Apolipoproteínas/toxicidade , Regulação da Expressão Gênica , Lipoproteínas HDL/toxicidade , RNA Polimerase I/metabolismo , Transcrição Gênica , Trypanosoma brucei rhodesiense/efeitos dos fármacos , Trypanosoma brucei rhodesiense/fisiologia , Adaptação Fisiológica , Apolipoproteína L1 , Haptoglobinas/análise , Humanos , Glicoproteínas de Membrana/biossíntese , Receptores de Superfície Celular/metabolismo , Soro/química , Trypanosoma brucei brucei/efeitos dos fármacos , Trypanosoma brucei brucei/genética , Trypanosoma brucei brucei/crescimento & desenvolvimento , Trypanosoma brucei gambiense/efeitos dos fármacos , Trypanosoma brucei gambiense/genética , Trypanosoma brucei gambiense/crescimento & desenvolvimento , Trypanosoma brucei rhodesiense/genética , Trypanosoma brucei rhodesiense/crescimento & desenvolvimento
7.
Clin Biochem ; 46(1-2): 79-84, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23041246

RESUMO

OBJECTIVES: Preliminary results of the IgA Hevylite™ assay including the establishment of the 95% reference interval and assessment of the specificity and sensitivity in different populations are reported. DESIGN AND METHODS: The concentrations of IgA heavy and light chains (HLC) enabling to determine an IgAκ/IgAλ ratio were quantified in 119 apparently healthy individuals to generate 95% reference intervals. The specificity of this assay was assessed in 48 patients with an isolated polyclonal IgA increase. In a retrospective analysis of 68 patients with a monoclonal component type IgA (MC-IgA) identified by serum immunofixation (IFE), IgA HLC ratio values were compared with known results for serum protein electrophoresis (SPE) and free light chain (FLC) ratios. RESULTS: The 95% reference range obtained in 119 controls (0.91-2.04) was close to that quoted by the manufacturer (0.80-2.04). Eight of the 48 patients (16.7%) with a polyclonal IgA increase had an IgA HLC ratio above the upper limit of the 95% reference interval. The IgA HLC ratio identified 65 (95.6%) among 68 patients with MC-IgA identified on the basis of IFE. For 34 of these patients (50%), MC-IgA was not detected by SPE due to its co-migration with alpha-2 or beta-globulins. CONCLUSIONS: Compared with serum IFE, the IgA HLC ratio has a sensitivity of 95.6%. Further studies are needed to assess the specificity of the IgA HLC ratio in patients with an isolated polyclonal increase of serum IgA.


Assuntos
Imunoglobulina A/sangue , Cadeias Pesadas de Imunoglobulinas/sangue , Cadeias Leves de Imunoglobulina/sangue , Paraproteinemias/sangue , Paraproteinemias/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Eletroforese das Proteínas Sanguíneas/métodos , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Controle de Qualidade , Valores de Referência , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...