Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Bone Miner Res ; 26(9): 2252-60, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21590741

RESUMO

Vitamin D deficiency has been linked to hypertension and an increased prevalence of cardiovascular risk factors and disease. Studies in vitamin D receptor knockout (VDR KO) mice revealed an overstimulated renin-angiotensin system (RAS) and consequent high blood pressure and cardiac hypertrophy. VDR KO mice correspond phenotypically and metabolically to humans with hereditary 1,25-dihydroxyvitamin D-resistant rickets (HVDRR). There are no data on the cardiovascular system in human HVDRR. To better understand the effects of vitamin D on the human cardiovascular system, the RAS, blood pressure levels, and cardiac structures were examined in HVDRR patients. Seventeen patients (9 males, 8 females, aged 6 to 36 years) with hereditary HVDRR were enrolled. The control group included age- and gender-matched healthy subjects. Serum calcium, phosphorous, creatinine, 25-hydroxyvitamin D [25(OH)D],1,25-dihydroxyvitamin D(3) [1,25(OH)(2) D(3) ], parathyroid hormone (PTH), plasma rennin activity (PRA), aldosterone, angiotensin II (AT-II), and angiotensin-converting enzyme (ACE) levels were determined. Ambulatory 24-hour blood pressure measurements and echocardiographic examinations were performed. Serum calcium, phosphorus, and alkaline phosphatase values were normal. Serum 1,25(OH)(2) D(3) and PTH but not PRA and ACE levels were elevated in the HVDRR patients. AT-II levels were higher than normal in the HVDRR patients but not significantly different from those of the controls. Aldosterone levels were normal in all HVDRR patients. No HVDRR patient had hypertension or echocardiographic pathology. These findings reveal that 6- to 36-year-old humans with HVDRR have normal renin and ACE activity, mild but nonsignificant elevation of AT-II, normal aldosterone levels, and no hypertension or gross heart abnormalities.


Assuntos
Pressão Sanguínea/fisiologia , Raquitismo Hipofosfatêmico Familiar/patologia , Raquitismo Hipofosfatêmico Familiar/fisiopatologia , Miocárdio/patologia , Sistema Renina-Angiotensina/fisiologia , Adolescente , Adulto , Animais , Cálcio/metabolismo , Estudos de Casos e Controles , Criança , Eletrocardiografia , Eletrólitos/metabolismo , Feminino , Frequência Cardíaca/fisiologia , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Camundongos , Minerais/metabolismo , Tamanho do Órgão , Adulto Jovem
2.
Cardiol Res Pract ; 2011: 316927, 2011 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-21318103

RESUMO

Objectives. We studied long-term effects of therapy for childhood lymphoma on cardiac function. Design and patients. We prospectively evaluated 45 survivors of childhood lymphoma, using clinical parameters, electrocardiography and echocardiography. Further comparisons were made between lymphoma subgroups and between males and females. Results. Mean age at diagnosis was 9.1 years. Mean followup duration was 10.9 years. The NYHA functional class was I in 43 patients and II in 2 patients. A prolonged QTc interval (>0.44 msec) was found in 8 patients. Left ventricular (LV) systolic function and compliance were normal (LV shortening fraction 40 ± 5.6%; cardiac index 2.84 ± 1.13 L/min/m(2); E/A wave ratio 2.5 ± 1.3; mean ± S.D.), LV mass was normal (97 ± 40 grams/m(2), mean ± S.D.). Mitral regurgitation was observed in 7/45 patients (16%). Asymptomatic pericardial effusions were found in 3/45 (7%) patients. Conclusions. Long-term follow-up shows that most parameters of cardiac function are normal in survivors of childhood lymphoma. This is likely due to relatively low doses of anthracyclines in modern protocol modalities. Abnormalities in mitral valve flow, QTc prolongation and in a small proportion of survivors, and functional capacity necessitate long-term cardiac follow-up of these patients.

3.
Congenit Heart Dis ; 5(1): 25-31, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20136854

RESUMO

OBJECTIVE: The secundum type of atrial septal defect (ASD) is a common congenital cardiac anomaly. Transcatheter closure of the defect is the preferable therapeutic approach to avoid potential future complications. This work extends the data collected so far regarding the electrocardiographic, morphologic, hemodynamic, and mechanical changes following the procedure. DESIGN: From April 2002 to October 2003, 42 consecutive patients underwent successful transcatheter closure of secundum type ASD. They were sampled for different parameters by transthoracic echocardiography before the procedure and at three different points over the next 4 years, and analyzed in two age groups: children and adults. RESULTS: The dimensions of the chambers normalized throughout the study period. Abnormal movement of the interventricular septum normalized mostly during the first month, but its thickness increased gradually to normal levels during the 4 years of the study. High elevated pulmonary artery pressure values began declining to near normal levels from the second month following the procedure. The stroke volume and the right bundle branch block pattern improved throughout the study period. CONCLUSIONS: Transcatheter ASD closure is followed by morphologic, conductive, and hemodynamic changes at different time intervals during the first years and results in normalization or near normalization of the heart's structure and function.


Assuntos
Cateterismo Cardíaco , Sistema de Condução Cardíaco/fisiopatologia , Comunicação Interatrial/terapia , Hemodinâmica , Adulto , Idoso , Pressão Sanguínea , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/terapia , Cateterismo Cardíaco/instrumentação , Criança , Pré-Escolar , Ecocardiografia , Eletrocardiografia , Feminino , Comunicação Interatrial/complicações , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/fisiopatologia , Hipertensão Pulmonar/terapia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Artéria Pulmonar/fisiopatologia , Dispositivo para Oclusão Septal , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda , Função Ventricular Direita , Septo Interventricular/diagnóstico por imagem , Septo Interventricular/fisiopatologia , Adulto Jovem
5.
Cardiol Young ; 14(5): 560-1, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15680080

RESUMO

We found spontaneous echoes in two teenagers with nephrotic syndrome and profound hypoalbuminemia, both having normal cardiac structure, function and output. The phenomenon disappeared after the level of albumin normalized. In one patient, all spontaneous echoes disappeared following convalescence, the level of albumin in the serum then being documented at normal levels. The second patient, who presented with profound hypoalbuminemia, was infused with human albumin because of oliguria, following which the spontaneous echoes disappeared.


Assuntos
Hipoalbuminemia/diagnóstico por imagem , Adolescente , Ecocardiografia , Humanos , Síndrome Nefrótica/complicações
6.
Cardiol Young ; 12(5): 465-9, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15773450

RESUMO

Occlusion using coils is now the treatment of choice for closure of the patent arterial duct. The DuctOcclud (pfm AG, Cologne, Germany) device is a relatively new retrievable coil for such trans-catheter closure. This study expands on previously reported experience with this device, summarizes the advantages of the device, and compares trans-pulmonary and trans-aortic delivery in 47 patients. There were 27 females. The mean, and median, ages were 4.6, and 2.85 years, respectively. The youngest patient was aged 9 months, weighing 7 kg. A trans-aortic delivery was used in 41 cases, and a trans-pulmonary approach in 6 cases. Of the 47 procedures, 45 (96%) were successful at the first attempt. The other two patients were treated successfully at the second attempt, giving a 100% rate of success. The technical characteristics of the coil allowed for its repeated maneuvering until an optimal position was obtained prior to release. Closure was confirmed by lack of ductal flow by echo-doppler on follow- up echocardiography. No short- or long-term complications of the procedure were noted in any of the patients. We conclude that the DuctOcclud device is an effective and safe method for closure of the small-to-moderately patent arterial duct. In a large proportion of patients, trans-aortic delivery is the preferred approach.


Assuntos
Cateterismo Cardíaco/instrumentação , Permeabilidade do Canal Arterial/cirurgia , Equipamentos e Provisões , Aorta/anormalidades , Aorta/cirurgia , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardiovasculares/instrumentação , Procedimentos Cirúrgicos Cardiovasculares/métodos , Pré-Escolar , Ecocardiografia , Estudos de Viabilidade , Feminino , Humanos , Lactente , Masculino , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...