Rev Port Cardiol (Engl Ed) ; 40(11): 865-873, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34857160

RESUMO

INTRODUCTION: Recurrent ventricular tachycardia (VT) episodes have a negative impact on the clinical outcome of implantable cardioverter-defibrillator (ICD) patients. Modification of the arrhythmogenic substrate has been used as a promising approach for treating recurrent VTs. However, there are limited data on long-term follow-up. AIM: To analyze long-term results of VT substrate-based ablation using high-density mapping in patients with severe left ventricular (LV) dysfunction and recurrent appropriate ICD therapy. METHODS: We analyzed 20 patients (15 men, 55% with non-ischemic cardiomyopathy, age 58±15 years, LV ejection fraction 32±5%) and repeated appropriate shocks or arrhythmic storm (>2 shocks/24 h) despite antiarrhythmic drug therapy and optimal heart failure medication. All patients underwent ventricular programmed stimulation (600 ms/S3) to document VT. A sinus rhythm (SR) voltage map was created with a three-dimensional electroanatomic mapping system (CARTO, Biosense Webster, CA) using a PentaRay® high-density mapping catheter (Biosense Webster, CA) to delineate areas of scarred myocardium (ventricular bipolar voltage ≤0.5 mV - dense scar; 0.5-1.5 mV - border zone; ≥1.5 mV - healthy tissue) and to provide high-resolution electrophysiological mapping. Substrate modification included elimination of local abnormal ventricular activities (LAVAs) during SR (fractionated, split, low-amplitude/long-lasting, late potentials, pre-systolic), and linear ablation to obtain scar homogenization and dechanneling. Pace-mapping techniques were used when capture was possible. The LV approach was retrograde in nine cases, transseptal in five and epi-endocardial in four. In two patients ablation was performed inside the right ventricle. RESULTS: LAVAs and scar areas were modified in all patients. Mean procedure duration was 149 min (105-220 min), with radiofrequency ranging from 18 to 70 min (mean 33 min) and mean fluoroscopy time of 15 min. Non-inducibility was achieved in 75% of cases (in four patients with hemodynamic deterioration and an LV assist device, VT inducibility was not performed). There were two cases of pericardial tamponade, drained successfully. During a follow-up of 50±24 months, 65% had no VT recurrences. Among the seven patients with recurrences, three underwent redo ablation and four, with fewer VT episodes, received appropriate ICD therapy. There were five hospital readmissions due to heart failure decompensation, one patient died in the first week after unsuccessful ablation of a VT storm and three died (stroke and pneumonia) >1 year after ablation. CONCLUSION: Catheter ablation based on substrate modification is feasible and safe in patients with frequent VTs and severe LV dysfunction. This approach may be of clinical relevance, with potential long-term benefits in reducing VT burden.


Assuntos
Cardiomiopatia Dilatada , Ablação por Cateter , Desfibriladores Implantáveis , Taquicardia Ventricular , Adulto , Idoso , Cardiomiopatia Dilatada/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/terapia , Resultado do Tratamento
2.
Rev Port Cardiol ; 36(3): 189-195, 2017 Mar.
Artigo em Inglês, Português | MEDLINE | ID: mdl-28258782

RESUMO

AIMS: There are conflicting data regarding the clinical benefits of device-based remote monitoring (RM). We sought to assess the effect of device-based RM on long-term clinical outcomes in recipients of implantable cardioverter-defibrillators (ICDs). METHODS: We assessed the incidence of adverse cardiac events, overall mortality and device therapy efficacy and safety in a propensity score-matched cohort of patients under RM compared to patients under conventional follow-up. Data on hospitalizations, mortality and cause of death were systematically assessed using a nationwide healthcare platform. The primary outcome was time to a composite outcome of first hospital admission for heart failure or cardiovascular death. RESULTS: Of a total of 923 implantable device recipients, 164 matched patients were identified (84 under RM, 84 under conventional follow-up). The mean follow-up was 44 months (range 1-123). There were no significant differences regarding baseline characteristics in the matched cohorts. Patients under RM had a significantly lower incidence of the primary outcome (hazard ratio [HR] 0.42, confidence interval [CI] 0.20-0.88, p=0.022); there was a non-significant trend towards lower overall mortality (HR 0.53, CI 0.27-1.04, p=0.066). No significant differences between cohorts were found regarding appropriate therapies (RM vs. conventional follow-up, 8.1 vs. 8.2%, p=NS) or inappropriate therapies (6.8 vs. 5.0%, p=NS). CONCLUSION: In a propensity score-matched cohort of ICD recipients with long-term follow-up, RM was associated with a lower rate of a combined endpoint of hospital admission for heart failure or cardiovascular death.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Tecnologia de Sensoriamento Remoto , Estudos de Coortes , Desfibriladores Implantáveis/efeitos adversos , Desfibriladores Implantáveis/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Admissão do Paciente/estatística & dados numéricos , Pontuação de Propensão , Melhoria de Qualidade , Estudos Retrospectivos , Fatores de Tempo
3.
Int J Cardiol ; 222: 764-768, 2016 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-27521554

RESUMO

AIMS: Device-based remote monitoring (RM) has been linked to improved clinical outcomes at short to medium-term follow-up. Whether this benefit extends to long-term follow-up is unknown. We sought to assess the effect of device-based RM on long-term clinical outcomes in recipients of implantable cardioverter-defibrillators (ICD). METHODS: We performed a retrospective cohort study of consecutive patients who underwent ICD implantation for primary prevention. RM was initiated with patient consent according to availability of RM hardware at implantation. Patients with concomitant cardiac resynchronization therapy were excluded. Data on hospitalizations, mortality and cause of death were systematically assessed using a nationwide healthcare platform. A Cox proportional hazards model was employed to estimate the effect of RM on mortality and a composite endpoint of cardiovascular mortality and hospital admission due to heart failure (HF). RESULTS: 312 patients were included with a median follow-up of 37.7months (range 1 to 146). 121 patients (38.2%) were under RM since the first outpatient visit post-ICD and 191 were in conventional follow-up. No differences were found regarding age, left ventricular ejection fraction, heart failure etiology or NYHA class at implantation. Patients under RM had higher long-term survival (hazard ratio [HR] 0.50, CI 0.27-0.93, p=0.029) and lower incidence of the composite outcome (HR 0.47, CI 0.27-0.82, p=0.008). After multivariate survival analysis, overall survival was independently associated with younger age, higher LVEF, NYHA class lower than 3 and RM. CONCLUSION: RM was independently associated with increased long-term survival and a lower incidence of a composite endpoint of hospitalization for HF or cardiovascular mortality.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Insuficiência Cardíaca/terapia , Monitorização Fisiológica/métodos , Telemedicina/métodos , Função Ventricular Esquerda/fisiologia , Morte Súbita Cardíaca/epidemiologia , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Portugal/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico/fisiologia , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...