Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Prehosp Emerg Care ; 23(3): 430-433, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30110189

RESUMO

We report a case of a 56 year old male in ventricular fibrillation (VF) cardiac arrest for a total of 2 hours and 50 minutes who was diagnosed with ST elevation myocardial infarction (STEMI) during a brief 10 min period of return of spontaneous circulation (ROSC). The patient underwent successful percutaneous coronary intervention (PCI) while receiving mechanical chest compressions for ongoing VF. Our case demonstrates the potential for neurologically intact survival in VF cardiac arrest patients despite prolonged periods of VF who are treated with mechanical CPR and intra-arrest PCI.


Assuntos
Reanimação Cardiopulmonar/instrumentação , Desfibriladores , Parada Cardíaca/terapia , Intervenção Coronária Percutânea , Sobrevida , Serviços Médicos de Emergência , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio com Supradesnível do Segmento ST , Fatores de Tempo , Resultado do Tratamento , Fibrilação Ventricular/terapia
2.
JACC Cardiovasc Interv ; 8(6): 824-833, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25999106

RESUMO

OBJECTIVES: The purpose of this study was to assess the diagnostic accuracy of the instantaneous wave-free ratio (iFR) to characterize, outside of a pre-specified range of values, stenosis severity, as defined by fractional flow reserve (FFR) ≤0.80, in a prospective, independent, controlled, core laboratory-based environment. BACKGROUND: Studies with methodological heterogeneity have reported some discrepancies in the classification agreement between iFR and FFR. The ADVISE II (ADenosine Vasodilator Independent Stenosis Evaluation II) study was designed to overcome limitations of previous iFR versus FFR comparisons. METHODS: A total of 919 intermediate coronary stenoses were investigated during baseline and hyperemia. From these, 690 pressure recordings (n = 598 patients) met core laboratory physiology criteria and are included in this report. RESULTS: The pre-specified iFR cut-off of 0.89 was optimal for the study and correctly classified 82.5% of the stenoses, with a sensitivity of 73.0% and specificity of 87.8% (C statistic: 0.90 [95% confidence interval (CI): 0.88 to 0.92, p < 0.001]). The proportion of stenoses properly classified by iFR outside of the pre-specified treatment (≤0.85) and deferral (≥0.94) values was 91.6% (95% CI: 88.8% to 93.9%). When combined with FFR use within these cut-offs, the percent of stenoses properly classified by such a pre-specified hybrid iFR-FFR approach was 94.2% (95% CI: 92.2% to 95.8%). The hybrid iFR-FFR approach obviated vasodilators from 65.1% (95% CI: 61.1% to 68.9%) of patients and 69.1% (95% CI: 65.5% to 72.6%) of stenoses. CONCLUSIONS: The ADVISE II study supports, on the basis rigorous methodology, the diagnostic value of iFR in establishing the functional significance of coronary stenoses, and highlights its complementariness with FFR when used in a hybrid iFR-FFR approach. (ADenosine Vasodilator Independent Stenosis Evaluation II-ADVISE II; NCT01740895).


Assuntos
Adenosina/administração & dosagem , Cateterismo Cardíaco , Estenose Coronária/diagnóstico , Reserva Fracionada de Fluxo Miocárdico , Vasodilatadores/administração & dosagem , Idoso , Algoritmos , Angiografia Coronária , Estenose Coronária/classificação , Estenose Coronária/fisiopatologia , Eletrocardiografia , Feminino , Hemodinâmica , Humanos , Hiperemia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Processamento de Sinais Assistido por Computador
3.
Nat Clin Pract Cardiovasc Med ; 4 Suppl 1: S27-39, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17230213

RESUMO

Adequate cell-based repair of adult myocardium remains an elusive goal because most cells that are used cannot generate mature myocardium sufficient to promote large functional improvements. Embryonic stem cells can generate both mature cardiocytes and vasculature, but their use is hampered by associated teratoma formation and the need for an allogeneic source. The detection of sca-1(+), c-kit(+), or isl-1(+) cardiac precursors and the creation of cardiospheres from adult heart tissues suggest that a persistent population of immature progenitor cells is present in the mature myocardium. These cell populations probably represent stages along a continuum of cardiac stem cell development and differentiation. We report isolation from ventricle of uncommitted cardiac progenitor cells, which appear to resemble the more immature, common pool of embryonic lateral plate mesoderm progenitors that yield both myocardial and endocardial cells during normal cardiac development. Under controlled in vitro conditions and in vivo, these cells can differentiate into endothelial, smooth muscle, and cardiomyocyte lineages and can be isolated and expanded to clinically relevant numbers from adult rat myocardial tissue. In this article, we discuss the potential for autologous repair or even cardiac regeneration with cells that follow a developmental pathway similar to embryonic cardiac precursors but without the inherent limitations associated with undifferentiated embryonic stem cells.


Assuntos
Coração/fisiologia , Miocárdio/citologia , Regeneração , Transplante de Células-Tronco , Células-Tronco/fisiologia , Adulto , Animais , Humanos , Ratos
5.
J Am Soc Echocardiogr ; 17(9): 981-7, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15337964

RESUMO

We sought to determine the hemodynamic performance of the Carpentier-Edwards Perimount pericardial valve in the mitral position. We reviewed the Doppler echocardiographic data on 189 patients (110 women; 68 +/- 12 years of age) who were implanted with this valve (7.6 days +/- 13 postoperatively) at our institution between September 2000 and May 2002. The average ejection fraction was 47%. For all valves, the peak velocity was 1.9 +/- 0.3 m/s, peak gradient was 15 +/- 4.8 mm Hg, and mean gradient was 5.8 +/- 2 mm Hg. The pressure half-time was 93 +/- 24 milliseconds, with a calculated effective orifice area of 2.5 +/- 0.6 cm2. The average effective orifice area by continuity equation (83 valves) was 1.5 +/- 0.5 cm2. The mitral regurgitation was graded mild or less in 97.5% of all valves. This is the largest series establishing the favorable hemodynamic behavior of the different sizes of a new Perimount mitral valve, and the reported data could serve as a reference.


Assuntos
Bioprótese , Circulação Coronária/fisiologia , Ecocardiografia Doppler/métodos , Próteses Valvulares Cardíacas , Valva Mitral/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
6.
J Am Coll Cardiol ; 41(10): 1739-43, 2003 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-12767657

RESUMO

OBJECTIVES: This study was designed to examine the impact of repeated intravascular ultrasound (IVUS) examinations on transplant coronary artery disease (CAD). BACKGROUND: Serial IVUS is the most accurate method for early detection and surveillance of transplant CAD. However, the long-term safety of serial IVUS exams is not well described. Accordingly, we examined the impact of repeated IVUS examinations on transplant CAD. METHODS: We examined 226 transplant recipients who underwent one or more IVUS examinations and coronary angiography at least one year after the last IVUS exam. The coronary angiograms were analyzed using quantitative coronary angiography. Vessel diameters, frequency, and severity of stenoses in IVUS-imaged and nonimaged coronary arteries were compared. In a subgroup analysis of 31 patients, angiographic lumen diameters were measured at baseline (within eight weeks of transplantation) and during follow-up (after two, three, or four IVUS studies). RESULTS: In the 226 patients, 548 coronary arteries were previously imaged by IVUS and 130 arteries were not imaged by IVUS. On subsequent angiograms, stenoses were observed in 16.2% (21/130) of nonimaged arteries and 19.5% (107/548) of imaged arteries (p = 0.38). The arterial diameters of nonimaged and imaged arteries were not significantly different (p = 0.07), regardless of the number of IVUS exams and duration of follow-up. Subgroup analysis revealed a significant decrease in vessel lumen diameter over time in nonimaged as well as imaged arteries. The magnitude of the diameter decrease was not significantly different between the two groups. CONCLUSIONS: Repeated IVUS examinations following heart transplantation do not result in angiographically evident acceleration of transplant CAD. Therefore, serial IVUS imaging is a safe method for the detection and surveillance of transplant CAD.


Assuntos
Doença das Coronárias/etiologia , Transplante de Coração/efeitos adversos , Ultrassonografia de Intervenção/efeitos adversos , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Feminino , Humanos , Masculino
7.
Am J Cardiol ; 91(4): 412-7, 2003 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-12586254

RESUMO

Transthoracic Doppler echocardiography (TDE) has been described as a feasible and accurate technique to noninvasively assess coronary flow reserve (CFR) in the left anterior descending artery (LAD). This study was designed to evaluate whether serial assessment of CFR in the LAD using TDE allows detection of restenosis after previously performed angioplasty. Thirty-three consecutive patients with single-vessel coronary artery disease of the LAD scheduled for angioplasty underwent assessment of coronary flow velocity at rest and during adenosine-induced hyperemia in the distal LAD using high-frequency TDE. CFR was calculated as the ratio of hyperemic to basal systolic/diastolic mean velocity. Investigations were performed before and immediately after angioplasty, and at the time of control angiography after 3 months. CFR results by TDE were compared with intracoronary Doppler guide wire measurements. Adequate pulse-wave Doppler signals to measure CFR were obtained in 30 patients (91%) using TDE. There was close correlation between echocardiographically and intracoronary derived CFR results (r = 0.80, 0.79, and 0.87 before angioplasty, early after, and at 3- month control angiography, respectively; p <0.001). Using a cut-off value of CFR < or =2.0 to identify significant coronary artery disease, TDE detected LAD restenosis with a sensitivity of 89% and specificity of 90%. Thus, high-frequency TDE is a feasible technique to noninvasively assess CFR in the LAD with results closely corresponding to invasive measurements. Defining a cut-off value of CFR < or =2.0, the technique has the potential to reliably detect LAD stenosis after coronary intervention.


Assuntos
Angioplastia Coronária com Balão , Velocidade do Fluxo Sanguíneo , Cateterismo Cardíaco/métodos , Circulação Coronária , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/terapia , Ecocardiografia Transesofagiana/métodos , Ultrassonografia de Intervenção/métodos , Adenosina , Idoso , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/normas , Angiografia Coronária , Doença das Coronárias/fisiopatologia , Diástole , Ecocardiografia Transesofagiana/normas , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Sensibilidade e Especificidade , Stents , Sístole , Ultrassonografia de Intervenção/instrumentação , Ultrassonografia de Intervenção/normas , Vasodilatadores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...