Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Hip Preserv Surg ; 8(4): 354-359, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35505810

RESUMO

The corona mortis (CM) is a vascular connection between the obturator and external iliac or internal epigastric vessels that has historically been identified as a source of hemorrhage in pelvic surgery. However, its frequency, location, proximity to the osteotomies performed, vascular contributions and impact on blood loss in patients undergoing periacetabular osteotomy (PAO) are unknown. We sought to identify the frequency, origin, location relative to osteotomies performed during surgery and impact on blood loss of the CM. Preoperative magnetic resonance imaging (MRI) of the hips of 28 adolescent patients (56 hips) undergoing PAO was retrospectively reviewed for the presence of a CM. When identifiable, the size, nature (arterial or venous), orientation, position relative to the iliopectineal eminence (IPE) and associated estimated blood loss (EBL) were recorded. 75% (21/28) of patients possessed an identifiable, ipsilateral CM to the site of PAO, 90% of which were venous and 10% arterial. The vessel was typically 8.3 ± 3.8 mm medial and 11.1 ± 5.3 mm caudal from the anterosuperomedial edge of the IPE. There was no significant difference in the amount of EBL (519 ± 260 versus 694 ± 369 ml) or need for post-op transfusions (1/21 versus 0/7) between patients who possessed a CM and those who did not, respectively (P = 0.21). CM was more prevalent in this study than previously reported. However, the presence of an ipsilateral CM was not associated with an increase in EBL or transfusion during routine PAO surgery using modern surgical techniques.

2.
J Acoust Soc Am ; 148(2): 614, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32872984

RESUMO

Three bottlenose dolphins (Tursiops truncatus) participated in simulated cylinder wall thickness discrimination tasks utilizing electronic "phantom" echoes. The first experiment resulted in psychometric functions (percent correct vs wall thickness difference) similar to those produced by a dolphin performing the task with physical cylinders. In the second experiment, a wide range of cylinder echoes was simulated, with the time separation between echo highlights covering a range from <30 to >300 µs. Dolphin performance and a model of the dolphin auditory periphery suggest that the dolphins used high-frequency, spectral-profiles of the echoes for discrimination and that the utility of spectral cues degraded when the time separation between echo highlights approached and exceeded the dolphin's temporal integration time of ∼264 µs.


Assuntos
Golfinho Nariz-de-Garrafa , Ecolocação , Animais , Sinais (Psicologia)
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...