Circ Arrhythm Electrophysiol ; 14(2): e009229, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33417475

RESUMO

BACKGROUND: Pulsed field ablation (PFA) is a nonthermal energy with potential safety advantages over radiofrequency ablation. This study investigated a novel PFA system-a circular multielectrode catheter (PFA lasso) and a multichannel generator designed to work with Carto 3 mapping system. METHODS: A 7.5F bidirectional circular catheter with 10 electrodes and variable expansion was designed for PFA (biphasic, 1800 Volts). This study included a total of 16 swine used to investigate the following 3 experimental aims: Aim 1 examined the feasibility to create a right atrial ablation line of block from the superior vena cava to the inferior vena cava. Aim 2 examined the effect of PFA on lesion maturation including durability after a 30-day survival period. Aim 3 examined the effect of high-intensity PFA (10 applications) on esophageal and phrenic nerve tissue in comparison to normal intensity radiofrequency ablation (1-2 applications). Histopathologic analysis of all cardiac, esophageal, and phrenic nerve tissue was performed. RESULTS: Acute line of block was achieved in 12/12 swine (100%) and required a total PFA time of 14 seconds (interquartile range [IQR], 9-24.5) per line. Ablation line durability after 28±3 days was maintained in 11/12 (91.7%) swine. PFA resulted in transmural lesions in 179/183 (97.8%) sections and a median lesion width of 14.2 mm. High-intensity PFA (9 [IQR, 8-14] application) had no effect on the esophagus while standard intensity radiofrequency ablation (1.5 [IQR, 1-2] applications) resulted in deep esophageal tissue injury involving the muscularis propria and adventitia layers. High-intensity PFA (16 [IQR, 10-28] applications) has no effect on phrenic nerve function and structure while standard dose radiofrequency ablation (1.5 [IQR, 1-2] applications) resulted in acute phrenic nerve paralysis. CONCLUSIONS: In this preclinical model, a multielectrode circular catheter and multichannel generator produced durable atrial lesions with lower vulnerability to esophageal or phrenic nerve damage.


Assuntos
Arritmias Cardíacas/cirurgia , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/instrumentação , Microeletrodos , Animais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Modelos Animais de Doenças , Desenho de Equipamento , Suínos
3.
J Cardiovasc Electrophysiol ; 30(5): 749-757, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30723994

RESUMO

INTRODUCTION: Multielectrode mapping catheters improve the ability to map within the heterogeneous scar. A novel Octaray catheter with eight spines and 48 electrodes may further improve the speed and resolution of atrial mapping. The aims of this study were to (1) establish the Octaray's baseline mapping performance and electrogram (EGM) characteristics in healthy atria and to (2) determine its utility for identifying gaps in a swine model of atrial ablation lines. METHODS AND RESULTS: The right atria of eight healthy swine were mapped with Octaray and Pentaray catheters (Biosense Webster, Irvine, CA) before and after the creation of ablation lines with intentional gaps. Baseline mapping characteristics including EGM amplitude, duration, number of EGMs, and mapping time were compared. Postablation maps were created and EGM characteristics of continuous lines and gaps were correlated with pathology. Compared with Pentaray, the Octaray collected more EGMs per map (2178 ± 637 vs 1046 ± 238; P < 0.001) at a shorter mapping duration (3.2 ± 0.79 vs 6.9 ± 2.67 minutes; P < 0.001). In healthy atria, the Octaray recorded lower bipolar voltage amplitude (1.96 ± 1.83 mV vs 2.41 ± 1.92 mV; P < 0.001) while ablation gaps were characterized by higher voltage amplitude (1.24 ± 1.12 mV vs 1.04 ± 1.27 mV; P < 0.001). Ablation gaps were similarly identified by both catheters (P = 1.0). The frequency of "false gaps," defined as intact ablation lines with increased voltage amplitude was more common with Pentaray (6 vs 2) and resulted from erroneous annotation of far-field EGMs. CONCLUSION: The Octaray increases the mapping speed and density compared with the Pentaray catheter. It is as sensitive for identifying ablation gaps and more specific for mapping intact ablation lines.


Assuntos
Potenciais de Ação , Cateteres Cardíacos , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Átrios do Coração/cirurgia , Frequência Cardíaca , Microeletrodos , Animais , Desenho de Equipamento , Átrios do Coração/fisiopatologia , Valor Preditivo dos Testes , Sus scrofa , Fatores de Tempo
4.
Circulation ; 113(2): 186-94, 2006 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-16401772

RESUMO

BACKGROUND: New ablation strategies for atrial fibrillation or nonidiopathic ventricular tachycardia are increasingly based on anatomic consideration and require the placement of ablation lesions at the correct anatomic locations. This study sought to evaluate the accuracy of the first clinically available image integration system for catheter ablation on 3-dimensional (3D) computed tomography (CT) images in real time. METHODS AND RESULTS: After midline sternotomy, 2.3-mm CT fiducial markers were attached to the epicardial surface of each cardiac chamber in 9 mongrel dogs. Detailed 3D cardiac anatomy was reconstructed from contrast-enhanced, high-resolution CT images and registered to the electroanatomic maps of each cardiac chamber. To assess accuracy, targeted ablations were performed at each of the fiducial markers guided only by the reconstructed 3D images. At autopsy, the position error was 1.9+/-0.9 mm for the right atrium, 2.7+/-1.2 mm for the right ventricle, 1.8+/-1.0 mm for the left atrium, and 2.3+/-1.1 mm for the left ventricle. To evaluate the system's guidance of more complex clinical ablation strategies, ablations of the cavotricuspid isthmus (n=4), fossa ovalis (n=4), and pulmonary veins (n=6) were performed, which resulted in position errors of 1.8+/-1.5, 2.2+/-1.3, and 2.1+/-1.2 mm, respectively. Retrospective analysis revealed that a combination of landmark registration and the target chamber surface registration resulted in <3 mm accuracy in all 4 cardiac chambers. CONCLUSIONS: Image integration with high-resolution 3D CT allows accurate placement of anatomically guided ablation lesions and can facilitate complex ablation strategies. This may provide significant advantages for anatomically based procedures such as ablation of atrial fibrillation and nonidiopathic ventricular tachycardia.


Assuntos
Ablação por Cateter/métodos , Tomografia Computadorizada por Raios X/métodos , Animais , Autopsia , Cães , Técnicas Eletrofisiológicas Cardíacas , Imageamento Tridimensional , Reprodutibilidade dos Testes , Estudos Retrospectivos