Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anesthesiology ; 127(2): 272-283, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28489614

RESUMO

BACKGROUND: This study compares the analgesic indices Analgesia Nociception Index (heart rate variability), Surgical Pleth Index (photoplethysmography), and pupillary dilatation, to heart rate, mean arterial pressure, and bispectral index, with regard to diagnostic accuracy and prediction probability for nociceptive response. The primary endpoint was the correlation between Δ values and the remifentanil dose administered. METHODS: We anesthetized 38 patients with propofol and increasing doses of remifentanil and applied standardized tetanic and intracutaneous electrical painful stimulations on each analgesic level. Baseline and Δ values of the Analgesia Nociception Index, the Surgical Pleth Index, pupillary dilatation, heart rate, mean arterial pressure, and bispectral index and their relation to remifentanil doses were analyzed by receiver operating characteristic curves, prediction probability (PK), and mixed-model analysis. RESULTS: Under propofol sedation, sensitivity and specificity of the Analgesia Nociception Index (PK = 0.98), the Surgical Pleth Index (PK = 0.87), and pupillary dilatation (PK = 0.98) for detecting both painful stimulations were high compared to heart rate (PK = 0.74), mean arterial pressure (PK = 0.75), and bispectral index (PK = 0.55). Baseline values had limited prediction probability toward the nociceptive response (Analgesia Nociception Index: PK = 0.7; Surgical Pleth Index: PK = 0.63; pupillary dilatation: PK = 0.67; and bispectral index: PK = 0.67). The remifentanil dose had an effect (P < 0.001) on all parameters except for bispectral index (P = 0.216). CONCLUSIONS: The Analgesia Nociception Index, the Surgical Pleth Index, and pupillary dilatation are superior in detecting painful stimulations compared to heart rate and mean arterial pressure but had limited predictive value. These effects are attenuated by increasing dosages of remifentanil. Our data confirm that bispectral index is not a marker of analgesia.


Assuntos
Anestesia Geral , Estimulação Elétrica , Monitorização Intraoperatória/métodos , Nociceptividade/efeitos dos fármacos , Piperidinas/farmacologia , Anestésicos Intravenosos/farmacologia , Pressão Arterial/efeitos dos fármacos , Eletroencefalografia/efeitos dos fármacos , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Pupila/efeitos dos fármacos , Remifentanil
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...