Resultados 1 - 20 de 28
Filtrar
1.
Front Bioeng Biotechnol ; 10: 840052, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35299640

RESUMO

Background: The most common type of fracture of the lateral tibial plateau is the Schatzker type II split-depressed fracture. Minimally invasive surgery using balloon reduction appears to be very promising compared to the gold standard using a bone tamp. This surgery aims to have the best reduction and stabilization to benefit from an early passive and active rehabilitation to avoid stiffening and muscle wasting. Using a balloon for fracture reduction has allowed the use of semi-liquid Injectable Bone Cement (IBC) fillers. These fillers can be phosphocalcic or polymethyl methacrylate (PMMA). The latest recommendations on these IBCs in spinal surgery increasingly rule out phosphocalcic fillers because of their low mechanical strength. Questions/purposes: 1) What is the mechanical influence of IBC filling (PMMA) regarding the split and depression components of a Schatzker type II fracture? 2) What is the mechanical influence of osteosynthesis regarding the split and depression components of a Schatzker type II fracture with or without PMMA filing in three different kinds of percutaneous fixations? Methods: This biomechanical study was performed on 36 fresh frozen tibia/fibula specimens. Six groups were formed according to the type of percutaneous osteosynthesis or possible PMMA filling. Mechanical strength tests were carried out using a Unicompartmental Knee prosthesis and displacement components were measured on either side of the separation on the anterolateral facet by optical method. Results: We found a significant difference between cementless and cemented osteosynthesis for depression fracture stabilization (difference -507.56N with 95% confidence interval [-904.17; -110.94] (p-value = 0.026)). The differences between the different types of osteosynthesis were not significant (p-value = 0.58). There was a significant difference between osteosynthesis without cement and osteosynthesis with cement on separation (difference -477.72N [-878.52; -76.93] (p-value = 0.03)). The differences between the different types of fixations were not significant regarding separation (p-value = 0.99). Conclusion: PMMA cement significantly improves primary stability, regardless of the type of osteosynthesis for a Schatzker type II plateau fracture. Filling with PMMA cement during tuberoplasty seems to be a very promising strategy in association with percutaneous osteosynthesis to allow rapid recovery after surgery.

2.
J Mech Behav Biomed Mater ; 122: 104663, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34246077

RESUMO

Minimally invasive methods, such as balloon kyphoplasty (BKP) and percutaneous sacroplasty (PS), which are now widely used for the surgical treatment of compression fractures, involve injection of a bolus of poly (methyl methacrylate) bone cement (hereafter, "bone cement") into the fractured tissue. Many of the common complications following these surgeries, such as cement leakage and adjacent-level fractures (in the case of BKP), have been postulated to be related to the quality of the cancellous bone-bone cement interface, which, in turn, is a function of its fracture resistance. It is common to use bovine cancellous bone or polyurethane foam (PF) as a substitute for human cancellous bone in biomechanical studies of these surgical methods. The literature is lacking in studies of determination of fracture properties of human cancellous bone-bone cement interface, bovine cancellous bone-bone cement interface, and PF-bone cement interface. In the present work, an integrated methodology (combination of wedge splitting test and Heaviside-based digital image correlation) was used to make these determinations as well as those for the bone cement, bones and the PF alone. The fracture properties determined were maximum fracture load (Fmax), fracture toughness (Kc), and specific fracture energy (Gf). For example, Gf values for human cancellous bone and human cancellous bone-bone interface were 0.48±0.14 N/mm and 0.38±0.05 N/mm, respectively, whereas in the case of bovine cancellous bone and bovine cancellous bone-bone cement interface, they were 1.08±0.11 N/mm and 0.22±0.05 N/mm, respectively, and for PF (Grades 12.5 and 15.0) and PF-bone cement interface, they were 0.81±0.12 and 0.55±0.06 N/mm, respectively. The same trends were seen in the Fmax and Kc results. These results suggest that it may not be justified to use either bovine cancellous bone or either of the PF grades as a substitute for human cadaveric cancellous bone in biomechanical studies of BKP, PS, and similar surgical methods.


Assuntos
Fraturas por Compressão , Cifoplastia , Fraturas da Coluna Vertebral , Animais , Cimentos Ósseos , Osso Esponjoso , Bovinos , Humanos , Polimetil Metacrilato
3.
Ann Chir Plast Esthet ; 66(2): 126-133, 2021 Apr.
Artigo em Francês | MEDLINE | ID: mdl-33707027

RESUMO

INTRODUCTION: The anatomical subject is still a key element to learn complex procedures in plastic surgery. We present here the evaluation of an in-training operator on a SIMLIFE® model, hyper realistic model consisting in human bodies donated to science equipped with pulsating recirculation and reventilation device. MATERIAL AND METHODS: From February 2019 to October 2019, 8 forearm flaps with radial proximal pedicle were harvested by the learner on a SIMLIFE® model. Conditions were as close as possible to the operating room : asepsy, sterile draping, assistant and instrumentation including electrocoagulation. RESULTS: The procedure was decomposed in 13 distinct steps. Mean total surgery time was 90,5±11,62minutes. There was only one case of arterial pedicle lesion resulting in major blood leak. Bleeding was measured by fake blood loss from the SIMLIFE® console. Mean intraoperatoy bleeding was 171±108 milliliters. We review pros and cons of this new technology particulary suited for complex plastic and reconstructive surgery training. CONCLUSION: Using SIMLIFE® technology we have a new mean to train for complex procedures in plastic and reconstructive surgery. This new technology could be applied to numerous other surgical procedures. Broader applications are still limited by cost and cadaver use legislation.


Assuntos
Procedimentos de Cirurgia Plástica , Retalhos Cirúrgicos , Cadáver , Simulação por Computador , Retroalimentação , Humanos
4.
Updates Surg ; 73(1): 289-295, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32876883

RESUMO

To evaluate the validity and reliability of an innovative training model for endocrine surgical procedures. A simulator training model for endocrine procedures (SimLife) was developed at an academic center. The model consisted of a realistic operating environment with a coherent simulated patient dynamized by pulsatile vascularization with simulated blood warmed to 37 °C, and ventilation. Training sessions were designed for adrenal and thyroid surgery, as well as neck dissection. The primary outcome of interest was to evaluate learners' performance and satisfaction. Learners' performance was evaluated based on a scoring scale that followed the Downing method for the assessment of competency. While learners' satisfaction was evaluated using a Likert scale of 1 to 10 on four items (ease of learning, anatomic correspondence of landmarks, realism, and overall satisfaction). Participants were engaged in 32 training sessions. These included 24 adrenalectomies (conventional and laparoscopic both transabdominal and posterior), and 4 thyroid lobectomies with concomitant functional lateral compartment neck dissection. competency scores were procedure-specific addressing specific core components of a given procedure. Learners' performance scored above average in all procedures evaluated. Satisfaction scores for the specified four items ranged between 8.43 (SD 0.87) and 8.89 (SD 0.96). No major events were reported for the adrenalectomies, while only one jugular vein injury occurred during neck dissection. SimLife is a hyper-realistic training model that allows for satisfactory acquisition of skills and the evaluation of performance progression. It has the potential to become a cornerstone in specialized surgical training.


Assuntos
Competência Clínica/estatística & dados numéricos , Simulação por Computador , Currículo , Educação Médica/métodos , Procedimentos Cirúrgicos Endócrinos/educação , Modelos Educacionais , Ensino , Glândulas Suprarrenais/cirurgia , Adrenalectomia/educação , Humanos , Esvaziamento Cervical/educação , Reprodutibilidade dos Testes , Glândula Tireoide/cirurgia , Tireoidectomia/educação
5.
Obes Surg ; 30(11): 4352-4358, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32621055

RESUMO

BACKGROUND: The demand for bariatric surgery is high and so is the need for training future bariatric surgeons. Bariatric surgery, as a technically demanding surgery, imposes a learning curve that may initially induce higher morbidity. In order to limit the clinical impact of this learning curve, a simulation preclinical training can be offered. The aim of the work was to assess the realism of a new cadaveric model for simulated bariatric surgery (sleeve and Roux in Y gastric bypass). AIM: A face validation study of SimLife, a new dynamic cadaveric model of simulated body for acquiring operative skills by simulation. The objectives of this study are first of all to measure the realism of this model, the satisfaction of learners, and finally the ability of this model to facilitate a learning process. METHODS: SimLife technology is based on a fresh body (frozen/thawed) given to science associated to a patented technical module, which can provide pulsatile vascularization with simulated blood heated to 37 °C and ventilation. RESULTS: Twenty-four residents and chief residents from 3 French University Digestive Surgery Departments were enrolled in this study. Based on their evaluation, the overall satisfaction of the cadaveric model was rated as 8.52, realism as 8.91, anatomic correspondence as 8.64, and the model's ability to be learning tool as 8.78. CONCLUSION: The use of the SimLife model allows proposing a very realistic surgical simulation model to realistically train and objectively evaluate the performance of young surgeons.


Assuntos
Cirurgia Bariátrica , Derivação Gástrica , Laparoscopia , Obesidade Mórbida , Competência Clínica , Humanos , Curva de Aprendizado , Obesidade Mórbida/cirurgia , Projetos Piloto
6.
J Visc Surg ; 157(3 Suppl 2): S117-S122, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32354683

RESUMO

In initial surgical formation and continuing surgical education, simulation has become a compulsory technique. Just as becoming an airplane pilot requires skills, the acquisition of technical skills is essential to becoming a surgeon. The old apprenticeship model "I see, I do, and I teach" is no longer entirely compatible with the socio-economic constraints of the operating room, demands for guaranteeing patient safety, and the compulsory reduction in resident working hours. We propose a new surgical simulation model, using cadavers donated to science that are rendered dynamic with pulsatile vascularization and ventilation. Such models are available for simulation of both open surgery and laparoscopy. Surgery on a human body donated to science makes it possible to accurately reproduce the hand gestures characteristic of surgical procedures. Learning in an appropriate and realistic simulation context increases the level of skills acquired by residents and reduces stress and anxiety when they come to perform real procedures.


Assuntos
Competência Clínica , Simulação por Computador , Currículo , Educação de Pós-Graduação em Medicina/métodos , Cirurgia Geral/educação , Internato e Residência/métodos , Treinamento por Simulação/métodos , Humanos
7.
Prog Urol ; 30(2): 126-133, 2020 Feb.
Artigo em Francês | MEDLINE | ID: mdl-31932042

RESUMO

INTRODUCTION: In 2015, we reported our experience with the learning curve in genital reassignment surgery and highlighted a four-step learning concept. CLINICAL CASE: In this article, we present our first vaginoplasty performed on a humanoid model SIMLIFE®, a human body associated with a pulsating circulation device and a ventilation device. RESULTS: The surgical technique included 14 steps. The total surgical time was 182minutes. There was no intraoperative complication, and there was no damage to the urethra or rectum. The intraoperative bleeding measured by the loss of operative fluid was 280mL. We discuss the advantages of this technology perfectly adapted to transsexual surgery. CONCLUSION: We demonstrated the feasibility of vaginoplasty performed on a humanoid model SIMLIFE® and highlighted improvement of the surgical skills with this model. This technology could find many other surgical applications. However, it faces cost constraints and legislation on corpses.


Assuntos
Cirurgia de Readequação Sexual/educação , Treinamento por Simulação/métodos , Transexualidade/cirurgia , Vagina/cirurgia , Perda Sanguínea Cirúrgica , Cadáver , Feminino , Humanos , Masculino , Duração da Cirurgia
8.
Clin Biomech (Bristol, Avon) ; 59: 27-33, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30142475

RESUMO

BACKGROUND: Schatzker type II tibial plateau fractures necessitate the least invasive treatment possible. Arthroscopic reduction by bone tamp followed by osteosynthesis is the current gold standard for this type of tibial plateau fracture. The objective of this study was to compare this technique to anterior approach tuberoplasty with balloon reduction. The comparison criteria were residual articular step off, metaphyseal cavity volume formed during reduction, and mechanical strength to separation and to depression displacement. METHODS: Fractures were created on 12 human cadaveric tibiae and reduced by a minimally invasive approach in six specimens by a balloon, and by bone tamp in the six others. Articular step off and metaphyseal-epiphyseal cavity volume were measured by TDM. Mechanical tests were performed up to assembly failure to characterize structural strength. Secondary displacements, fracture depression displacement and separation were measured by optical methods. FINDINGS: There was no significant difference in step off measurement after balloon reduction or bone tamp (0.29 cm vs 0.37 cm; p = 0.06). The cavity volume formed by balloon reduction was significantly smaller than the volume created by bone tamp reduction (0.45 cm3 vs 5.12 cm; p = 0.002). The compressive load required for assembly failure was significantly greater in the balloon group than in the bone tamp group (1210.17 N vs 624.50 N; p = 0.015). INTERPRETATION: There exists a correlation between load to failure of the assembly frame and the metaphyseal volume required for bone fracture reduction. The minimally invasive balloon technique has fewer negative effects on the osseous stock, thereby enabling better primary structural strength of the fracture.


Assuntos
Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fraturas da Tíbia/cirurgia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Osso e Ossos/cirurgia , Cadáver , Força Compressiva , Feminino , Humanos , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos , Procedimentos de Cirurgia Plástica , Estresse Mecânico , Tíbia/cirurgia
9.
Clin Biomech (Bristol, Avon) ; 56: 27-35, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29777960

RESUMO

BACKGROUND: Treatment for fractures of the tibial plateau is in most cases carried out by stable fixation in order to allow early mobilization. Minimally invasive technologies such as tibioplasty or stabilization by locking plate, bone augmentation and cement filling (CF) have recently been used to treat this type of fracture. The aim of this paper was to determine the mechanical behavior of the tibial plateau by numerically modeling and by quantifying the mechanical effects on the tibia mechanical properties from injury healing. METHODS: A personalized Finite Element (FE) model of the tibial plateau from a clinical case has been developed to analyze stress distribution in the tibial plateau stabilized by balloon osteoplasty and to determine the influence of the cement injected. Stress analysis was performed for different stages after surgery. FINDINGS: Just after surgery, the maximum von Mises stresses obtained for the fractured tibia treated with and without CF were 134.9 MPa and 289.9 MPa respectively on the plate. Stress distribution showed an increase of values in the trabecular bone in the treated model with locking plate and CF and stress reduction in the cortical bone in the model treated with locking plate only. INTERPRETATION: The computed results of stresses or displacements of the fractured models show that the cement filling of the tibial depression fracture may increase implant stability, and decrease the loss of depression reduction, while the presence of the cement in the healed model renders the load distribution uniform.


Assuntos
Cimentos Ósseos/química , Placas Ósseas , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fraturas da Tíbia/cirurgia , Acidentes por Quedas , Adulto , Fenômenos Biomecânicos , Feminino , Análise de Elementos Finitos , Consolidação da Fratura , Humanos , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos , Resistência ao Cisalhamento , Estresse Mecânico , Tíbia/cirurgia
10.
Hand Surg Rehabil ; 37(1): 24-29, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29248396

RESUMO

Tendon grafts are a component of the therapeutic arsenal for managing chronic flexor tendons injuries in the hand, especially during two-stage Hunter reconstruction. The purpose of this anatomical study was to compare the strength of the Pulvertaft weave versus the step-cut suture used for flexor tendon reconstruction to determine their role in early active mobilization. We performed a biomechanical study with cadaver specimens. Thirty-four hands were randomized and the tendons from both hands were equally assigned to each group. A comparison of the Pulvertaft weave (group 1) versus the step-cut suture (group 2) using the flexor digitorum profundus from the fourth finger and the longus palmaris was carried out. The main variable was the failure load in both repair groups. We also evaluated the cross-sectional area (CSA) and the tensile strength of the repairs. Thirty hands were included in our study. There was no significant difference in the failure load between the two groups (116N for group 1 versus 103N for group 2, P=0.2). The CSA was significantly smaller in the step-cut group compared to Pulvertaft group (19.8mm2 versus 35mm2, P<0.01). The tensile strength was significantly higher in the step-cut group than in the Pulvertaft group (5.3N/mm2 versus 3.4N/mm2, P<0.01). Early active mobilization requires a minimum repair strength of 75N. In our study, the step-cut suture appears strong enough and thin enough to decrease the fibrosis, which would lead to better functional results. No other study of this type has been published. The specimens in which the repair strength was less than 75N all involved a thin, weak longus palmaris. Other biomechanical studies should be done to define the anatomical criteria required for use of the palmaris longus tendon. The step-cut suture seems to be strong enough and thin enough to provide sufficient proximal attachment during flexor tendon reconstruction to allow early active mobilization.


Assuntos
Técnicas de Sutura , Tendões/cirurgia , Resistência à Tração , Cadáver , Humanos , Distribuição Aleatória
13.
Clin Biomech (Bristol, Avon) ; 49: 139-144, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28938147

RESUMO

BACKGROUND: Burst fractures represent a significant proportion of fractures of the thoracolumbar junction. The recent advent of minimally invasive techniques has revolutionized the surgical treatment of this type of fracture. However mechanical behaviour and primary stability offered by these solutions have to be proved from experimental validation tests on cadaveric specimens. Therefore, the aim of this study was to develop an original and reproducible model of burst fracture under dynamic impact. METHODS: Experimental tests were performed on 24 cadaveric spine segments (T11-L3). A system of dynamic loading was developed using a modified Charpy pendulum. The mechanical response of the segments (strain measurement on vertebrae and discs) was obtained during the impact by using an optical method with a high-speed camera. The production of burst fracture was validated by an analysis of the segments by X-ray tomography. FINDINGS: Burst fracture was systematically produced on L1 for each specimen. Strain analysis during impact highlighted the large deformation of L1 due to the fracture and small strains in adjacent vertebrae. The mean reduction of the vertebral body of L1 assessed for all the specimens was around 15%. No damage was observed in adjacent discs or vertebrae. INTERPRETATION: With this new, reliable and replicable procedure for production and biomechanical analysis of burst fractures, comparison of different types of stabilization systems can be envisaged. The loading system was designed so as to be able to produce loads leading to other types of fractures and to provide data to validate finite element modelling.


Assuntos
Modelos Biológicos , Fraturas da Coluna Vertebral/etiologia , Vértebras Torácicas/lesões , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos/fisiologia , Cadáver , Feminino , Humanos , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/fisiopatologia , Vértebras Torácicas/diagnóstico por imagem
14.
J Exp Orthop ; 4(1): 9, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28332149

RESUMO

BACKGROUND: Purpose and hypothesis: Patellar ligament rupture is a rare disabling pathology requiring a surgical ligament suture protected by a frame. The gold standard is the steel cable, but its rigidity and the necessity of a surgical re-intervention for its removal render it unsatisfactory. The objective of this paper is to quantify the mechanical protection provided by the terylene® in comparison with steel. METHODS: Twenty-four knees of 12 fresh frozen cadaveric subjects were divided into 2 homogeneous groups (terylene and steel) of 12 knees (mean age = 69.3 years). Proximal ligament repair was performed according to a three-tunnel transosseous reinsertion technique. Mechanical tests were performed in flexion to simulate movement of the knee. The interligament gap and the amplitude angulation of the knee were measured by a system of extensometer and optical goniometer. Mechanical analysis permitted calculation of flexion amplitude for a ligament gap of 1 and 2 mm taking as initial angle the adjusting angle of pretension of the protection frame. Study of deformations of frames was performed. Statistical analysis was performed with a Wilcoxon Mann Whitney test. RESULTS: There is no significant difference in protection of the ligament suture between the "terylene" and "steel" groups. Mean flexion amplitudes (mΔF) show no significant differences between the 2 groups for a distension of the suture of 1 mm (m ΔF terylene1 = 4.74 °; mΔF steel1 = 5.91°; p = 0.198) and 2 mm (mΔF terylene2 = 8.71°; mΔF steel2 = 10.41°; p = 0.114). Elastic deformation of terylene was significantly greater than that of steel (p = 0.0004). CONCLUSION: Suture protection of the patellar ligament by a terylene wire is not significantly different from that provided by steel frame. The elastic properties of terylene and absence of a need for re intervention to secure its removal lead us towards its use in acute ruptures of the patellar ligament. The main limits involve the properties of the chain extenders with no contraction/muscle shortening and partial dehydration of tendons and ligaments and the mean age of 69.3 years. Level 5.

15.
Surg Radiol Anat ; 39(2): 211-217, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27315801

RESUMO

PURPOSE: In primary and continuing medical education, simulation is becoming a mandatory technique. In surgery, simulation spreading is slowed down by the distance which exists between the devices currently available on the market and the reality, in particular anatomical, of an operating room. We propose a new model for surgical simulation with the use of cadavers in a circulation model mimicking pulse and artificial respiration available for both open and laparoscopic surgery. METHODS: The model was a task trainer designed by four experts in our simulation laboratory combining plastic, electronic, and biologic material. The cost of supplies needed for the construction was evaluated. The model was used and tested over 24 months on 35 participants, of whom 20 were surveyed regarding the realism of the model. RESULTS: The model involved a cadaver, connected to a specific device that permits beating circulation and artificial respiration. The demonstration contributed to teaching small groups of up to four participants and was reproducible over 24 months of courses. Anatomic correlation, realism, and learning experience were highly rated by users CONCLUSION: This model for surgical simulation in both open and laparoscopic surgery was found to be realistic, available to assessed objectively performance in a pedagogic program.


Assuntos
Educação Médica/métodos , Treinamento com Simulação de Alta Fidelidade/métodos , Procedimentos Cirúrgicos Operatórios/educação , Cadáver , Humanos , Inquéritos e Questionários
16.
J Visc Surg ; 154(1): 15-20, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27344609

RESUMO

INTRODUCTION: Alike becoming a pilot requires competences, acquisition of technical skills is essential to become a surgeon. Halsted's theory on surgical education "See one, do one, and teach one" is not currently compatible with the reality of socio-economic constraints of the operating room, the patient's safety demand and the reduction of residents' work hours. MATERIEL AND METHODS: In all countries, this brings mandatory to simulation education for surgery resident's training. Many models are available: video trainers or pelvi-trainers, computed simulator, animal models or human cadaver… Human cadaveric dissection has long been used to teach surgical anatomy. RESULTS: Surgery on human cadaveric model brings greatest accuracy to the haptic characteristics of surgical procedures. Learning in an appropriate and realistic simulation context increases the level of acquisition of the residents' skills and reduces stress and anxiety when performing real procedures. CONCLUSION: We present a technique of perfusion and ventilation of a fresh human cadaver that restores pulsatile circulation and respiratory movements of the model.


Assuntos
Competência Clínica , Dissecação/educação , Cabeça/irrigação sanguínea , Internato e Residência , Pescoço/irrigação sanguínea , Tronco/irrigação sanguínea , Cadáver , Simulação por Computador , Humanos , Salas Cirúrgicas
17.
J Mech Behav Biomed Mater ; 59: 291-303, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26896762

RESUMO

Kyphoplasty has been shown as a well-established technique for spinal injuries. This technique allows a vertebral bone augmentation with a reduction of morbidity and does not involve any adjacent segment immobilisation. There is a lack of biomechanical information resulting in major gaps of knowledge such as: the evaluation of the "quality" of stabilisation provided by kyphoplasty as a standalone procedure in case of unstable fracture. Our objective is to analyse biomechanical response of spine segments stabilised by Kyphoplasty and PMMA cement after experiencing burst fractures. Six fresh-frozen cadaveric spine specimens constituted by five vertebra (T11-L3) and four disks were tested. A specific loading setup has been developed to impose pure moments corresponding to loadings of flexion-extension, lateral bending and axial rotation. Tests were performed on each specimen in an intact state and post kyphoplasty following a burst fracture. Strain measurements and motion variations of spinal unit are measured by a 3D optical method. Strain measurements on vertebral bodies after kyphoplasty shows a great primary stabilisation. Comparisons of mobility and angles variations between the intact and post kyphoplasty states do not highlight significant difference. Percutaneous kyphoplasty offers a good primary stability in case of burst fracture. Kinematics analysis during physiological movements shows that this stabilisation solution preserve disk mobility in each adjacent spinal unit.


Assuntos
Cimentos Ósseos , Cifoplastia , Vértebras Lombares/cirurgia , Fraturas da Coluna Vertebral/cirurgia , Vértebras Torácicas/cirurgia , Fenômenos Biomecânicos , Cadáver , Humanos
18.
Orthop Traumatol Surg Res ; 102(1): 61-5, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26796997

RESUMO

INTRODUCTION: Kyphoplasty has proved effective for durable correction of traumatic vertebral deformity following Magerl A fracture, but subsequent behavior of the adjacent discs is unclear. The objective of the present study was to analyze evolution according to severity of initial kyphosis and quality of fracture reduction. MATERIAL AND METHOD: A single-center prospective study included cases of single compression fracture of the thoracolumbar hinge managed by Kyphon Balloon Kyphoplasty with polymethylmethacrylate bone cement. Radiology focused on traumatic vertebral kyphosis (VK), disc angulation (DA) and disc height index (DHI) in the adjacent discs. Linear regression assessed the correlation between superior disc height index (SupDHI) and postoperative VK on the one hand and correction gain on the other, using the Student t test for matched pairs and Pearson correlation coefficient. RESULTS: Fifty-two young patients were included, with mean follow-up of 18.6 months. VK fell from 13.9° preoperatively to 8.2° at last follow-up. DHI found significant superior disc subsidence (P=0.0001) and non-significant inferior disc subsidence (P=0.116). DA showed significantly reduced superior disc lordosis (P=4*10(-5)). SupDHI correlated with VK correction (r=0.32). Preoperative VK did not correlate with radiologic degeneration of the adjacent discs. CONCLUSION: Correction of traumatic vertebral deformity avoids subsidence and loss of mechanical function in the superior adjacent disc. The underlying disc compensates for residual deformity. Balloon kyphoplasty is useful in compression fracture, providing significant reduction of traumatic vertebral deformity while conserving free and healthy adjacent discs. LEVEL OF EVIDENCE: IV.


Assuntos
Fraturas por Compressão/diagnóstico por imagem , Disco Intervertebral/diagnóstico por imagem , Cifoplastia/métodos , Vértebras Lombares/lesões , Fraturas da Coluna Vertebral/diagnóstico por imagem , Vértebras Torácicas/lesões , Adulto , Idoso , Feminino , Fraturas por Compressão/cirurgia , Humanos , Disco Intervertebral/lesões , Disco Intervertebral/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia , Fraturas da Coluna Vertebral/cirurgia , Adulto Jovem
19.
Orthop Traumatol Surg Res ; 101(2): 215-9, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25736197

RESUMO

BACKGROUND: Lumbar spinal stenosis is a major public health issue. Interspinous devices implanted using minimally invasive techniques may constitute an alternative to the reference standard of bony decompression with or without intervertebral fusion. However, their indications remain unclear, due to a paucity of clinical and biomechanical data. Our objective was to evaluate the effects of four interspinous process devices implanted at L4-L5 on the intervertebral foramen surface areas at the treated and adjacent levels, in flexion and in extension. MATERIALS AND METHOD: Six fresh frozen human cadaver lumbar spines (L2-sacrum) were tested on a dedicated spinal loading frame, in flexion and extension, from 0 to 10 N·m, after preparation and marking of the L3-L4, L4-L5, and L5-S1 foramina. Stereoscopic 3D images were acquired at baseline then after implantation at L4-L5 of each of the four devices (Inspace(®), Synthes; X-Stop(®), Medtronic; Wallis(®), Zimmer; and Diam(®), Medtronic). The surface areas of the three foramina of interest were computed. RESULTS: All four devices significantly opened the L4-L5 foramen in extension. The effects in flexion separated the devices into two categories. With the two devices characterized by fixation in the spinous processes (Wallis(®) and Diam(®)), the L4-L5 foramen opened only in extension; whereas with the other two devices (X-Stop(®) and Inspace(®)), the L4-L5 foramen opened not only in extension, but also in flexion and in the neutral position. None of the devices implanted at L4-L5 modified the size of the L3-L4 foramen. X-Stop(®) and Diam(®) closed the L5-S1 foramen in extension, whereas the other two devices had no effect at this level. CONCLUSION: Our results demonstrate that interspinous process devices modify the surface area of the interspinous foramina in vitro. Clinical studies are needed to clarify patient selection criteria for interspinous process device implantation. LEVEL OF EVIDENCE: Level IV. Investigating an orthopaedic device.


Assuntos
Vértebras Lombares/cirurgia , Próteses e Implantes , Amplitude de Movimento Articular/fisiologia , Sacro/cirurgia , Fusão Vertebral/instrumentação , Estenose Espinal/cirurgia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Cadáver , Descompressão Cirúrgica/instrumentação , Humanos , Imageamento Tridimensional , Vértebras Lombares/fisiopatologia , Teste de Materiais , Período Pós-Operatório , Desenho de Prótese , Sacro/fisiopatologia , Estenose Espinal/diagnóstico
20.
Chir Main ; 32(5): 322-8, 2013 Oct.
Artigo em Francês | MEDLINE | ID: mdl-24094570

RESUMO

Proximal or middle lesions of median or ulnar nerves are responsible for a great loss of hand motor function. Neurotization of either deep ulnar branch of ulnar nerve (DBUN) or recurrent (thenar) branch of median nerve (RBMN) with the nerve to quadratus pronator (NPQ) from the anterior interosseous nerve (AION) could reduce length of axonal growth and therefore the reinnervation lead-time of hand intrinsic muscles. We studied the anatomy of these three nerves, to help surgeon choosing his (her) technique and approach. Twenty-three cadaver forearms were dissected. End-to-side sutures were performed to mimic these neurotizations. Distances between nerve sutures and ulnar styloid process (USP) or trapeziometacarpal joint (TM) were measured. All the sutures but one RBMN could be done. On average sutures were distant from USP by 44±17mm (neurotization of DBUN), from TM by 62±15mm (neurotization of RBMN). Knowledge of average distance to perform these neurotizations should allow choosing the best reduced approach of RBMN and DBUN. Neurotizations of DBNU and RBMN with NPQ were feasible for lesions located at 6.1cm upstream USP and 7.7cm upstream TM, respectively. End-to-side sutures remain to be clinically evaluated.


Assuntos
Nervo Mediano/cirurgia , Transferência de Nervo/métodos , Nervo Ulnar/cirurgia , Anastomose Cirúrgica , Cadáver , Humanos , Regeneração Nervosa , Nervos Periféricos/transplante