Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Urol ; 164(6): 2099-103, 2000 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11061935

RESUMO

PURPOSE: The pattern of flow in the stented ureter (intraluminal and/or extra luminal) has only been defined for the standard pigtail stent. No data are available on stent flow for any specialty stents. To our knowledge we present the first investigation characterizing the type of flow through a stent (Poiseuille versus nonPoiseuille flow). MATERIALS AND METHODS: Flow was measured in an unstented ureter, a standard 7Fr double pigtail stent and the 7/3Fr Tail stent, 7Fr Spirastent and 14/7Fr endopyelotomy stent using a previously developed stent flow model. In vitro pressure flow studies were also done in nonfenestrated 14/7Fr, Tail and standard 7Fr stents. These stents were infused at a constant flow rate of 2 to 10 ml. per minute with monitoring of the corresponding pressure gradients. Resistance to flow was determined for these stents using pressure flow plots and Poiseuille's law. RESULTS: In vivo the 7Fr pigtail, 14/7Fr endopyelotomy and 7/3Fr Tail stents had statistically similar flow rates. Flow through each of these stents exceeded the flow through an unstented ureter. The Spirastent had the least flow in all categories tested. There was no correlation of Poiseuille flow parameters measured in vitro for nonfenestrated stents with in vivo stent flow. CONCLUSIONS: In stented ureters fluid drains through and around the stent regardless of its design. The flow characteristics of these 3 specialty stents were not predictable according to lumen or stent size. In vitro Poiseuille's flow did not correlate with in vivo stent flow.


Assuntos
Stents , Ureter , Urodinâmica , Animais , Desenho de Equipamento , Modelos Estruturais , Pressão , Porco Miniatura , Ureter/fisiologia
2.
J Endourol ; 14(2): 203-11, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10772516

RESUMO

BACKGROUND AND PURPOSE: A variety of biodegradable organic materials have been used for bladder wall replacement. In some instances, partial replacement has been done using laparoscopic reconstructive techniques. However, to date, this activity has been limited to small patches. Herein, we present the initial experience with laparoscopic sagittal hemicystectomy and the use of laparoscopic reconstructive techniques to replace half of the bladder with small-intestinal submucosa (SIS) and to reimplant the ureter into SIS. MATERIALS AND METHODS: Six female minipigs (20-25 kg) underwent transperitoneal laparoscopic sagittal hemicystectomy; the excised bladder wall was replaced with a 5 x 15-cm patch of SIS (Cook Biotechnology, Spencer, IN). The ipsilateral ureter was reimplanted through a small incision in the graft and secured with two sutures. Cystoscopy and cystometrograms were performed under general anesthesia preoperatively and at 6 and 12 weeks postoperatively. Tissues were harvested at 12 weeks. RESULTS: The procedure was successful in six animals (left three, right three). During cystoscopy at 12 weeks, the area of the graft was not distinguishable from normal mucosa. Cystometrograms revealed maintenance of volume and compliance, with volumes of 338, 343, and 369 mL and intravesical leak-point pressures of 37, 59, and 39 cm H2O at 0, 6, and 12 weeks, respectively. Antegrade ureterograms demonstrated extrinsic obstruction, minimal (two), moderate (three), or complete (one), at the ureterovesical junction. The kidney associated with the completely obstructed ureter was grossly hydronephrotic at sacrifice. Histologically, patchy epithelialization of the graft with a mixture of squamoid and mature transitional-cell epithelium was found. CONCLUSIONS: Laparoscopic hemicystectomy with replacement of the bladder wall and implantation of the ureter into the SIS graft is a feasible procedure. Clinical application awaits improvements in the method of ureteral reimplantation and longer follow-up to assess for ingrowth of muscle and nerve fibers.


Assuntos
Mucosa Intestinal/transplante , Intestino Delgado/transplante , Laparoscopia , Reimplante , Ureter/cirurgia , Bexiga Urinária/cirurgia , Anastomose Cirúrgica , Animais , Estudos de Viabilidade , Feminino , Período Pós-Operatório , Radiografia , Suínos , Porco Miniatura , Bexiga Urinária/diagnóstico por imagem , Bexiga Urinária/patologia
3.
J Endourol ; 13(4): 269-71, 1999 May.
Artigo em Inglês | MEDLINE | ID: mdl-10405904

RESUMO

BACKGROUND AND OBJECTIVES: The flow characteristics of ureteral stents have yet to be clearly defined. In this study, flow mechanics were studied in several silicone-based stents including 4.8F, 7F, and 10.3F pigtail; 7F Tower; and a prototype mesh stent. MATERIALS AND METHODS: Forty-five female Yucatan minipigs underwent bilateral laparoscopic occlusion of their renal vessels to stop urine production. A nephrostomy tract was established by retrograde puncture. A stent was placed in the ureter, and three measurements were taken with flow from a bag of irrigant 20 cm above the kidney: stent occluded with a guidewire (extraluminal flow), stent unobstructed (total flow), and laparoscopically placed extraureteral ligature (luminal flow). RESULTS: Luminal flow and, to a lesser extent, total flow appeared to increase as the internal and external diameters of the stent increased. The Tower stent, which had no sideholes, had much lower flow rates in all categories, while the prototype mesh stent showed greater total flow compared with the other stents. Extraluminal flow did not increase with stent size greater than 7F. CONCLUSIONS: Luminal flow, but not extraluminal flow, increased with an increase in the internal diameter of the stent. In general, the least favorable flow occurred with a Tower stent, which had the smallest internal diameter. The greatest flow was seen with the prototype mesh stent.


Assuntos
Materiais Biocompatíveis , Silicones , Stents , Obstrução Ureteral/fisiopatologia , Urodinâmica , Animais , Modelos Animais de Doenças , Feminino , Masculino , Suínos , Porco Miniatura , Obstrução Ureteral/diagnóstico , Obstrução Ureteral/cirurgia , Ureteroscopia , Urografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...