Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Transpl Infect Dis ; 17(6): 848-58, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26442607

RESUMO

BACKGROUND: BK polyomavirus (BKPyV) viremia/nephropathy and reduction in immunosuppression following viremia may increase the risk of alloimmune activation and allograft rejection. This study investigates the impact of BKPyV viremia on de novo donor anti-human leukocyte antigen (HLA)-specific antibodies (dnDSA). PATIENTS AND METHODS: All primary renal transplants at East Carolina University from March 1999 to December 2010, with at least 1 post-transplant BKPyV viral load testing, were analyzed. Patients were negative for anti-HLA antibodies to donor antigens (tested via single antigen beads) at transplantation and at first BKPyV testing. RESULTS: Nineteen of 174 patients (11%) tested positive for BKPyV viremia. Within 24 months of BKPyV viremia detection, 79% of BKPyV-viremic patients developed dnDSA. Only 20% of BKPyV viremia-persistent cases, compared to 86% of BKPyV viremia-resolved cases, developed dnDSA (P = 0.03). Poor allograft survival was evident in BKPyV viremia-persistent patients (60% failure by 2 years post BKPyV diagnosis) and in BKPyV viremia-resolved patients with dnDSA (5-year post BKPyV diagnosis allograft survival of 48%). CONCLUSIONS: Post-transplant BKPyV viremia and preemptive immunosuppression reduction is associated with high rates of dnDSA. When preemptively treating BKPyV viremia, dnDSA should be monitored to prevent allograft consequences.


Assuntos
Anticorpos/sangue , Vírus BK/isolamento & purificação , Antígenos HLA/imunologia , Terapia de Imunossupressão/efeitos adversos , Infecções por Polyomavirus/imunologia , Infecções Tumorais por Vírus/imunologia , Adulto , Relação Dose-Resposta a Droga , Feminino , Humanos , Imunossupressores/administração & dosagem , Imunossupressores/uso terapêutico , Transplante de Rim/efeitos adversos , Masculino , Pessoa de Meia-Idade , Infecções por Polyomavirus/sangue , Infecções Tumorais por Vírus/sangue , Viremia
2.
Am J Transplant ; 13(10): 2577-89, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23941128

RESUMO

Reports have associated non-HLA antibodies, specifically those against angiotensin II type-1 receptor (AT1R), with antibody-mediated kidney graft rejection. However, association of anti-AT1R with graft failure had not been demonstrated. We tested anti-AT1R and donor-specific HLA antibodies (DSA) in pre- and posttransplant sera from 351 consecutive kidney recipients: 134 with biopsy-proven rejection and/or lesions (abnormal biopsy group [ABG]) and 217 control group (CG) patients. The ABG's rate of anti-AT1R was significantly higher than the CG's (18% vs. 6%, p < 0.001). Moreover, 79% of ABG patients with anti-AT1R lost their grafts (vs. 0%, CG), anti-AT1R levels in 58% of those failed grafts increasing posttransplant. With anti-AT1R detectable before DSA, time to graft failure was 31 months-but 63 months with DSA detectable before anti-AT1R. Patients with both anti-AT1R and DSA had lower graft survival than those with DSA alone (log-rank p = 0.007). Multivariate analysis showed that de novo anti-AT1R was an independent predictor of graft failure in the ABG, alone (HR: 6.6), and in the entire population (HR: 5.4). In conclusion, this study found significant association of anti-AT1R with graft failure. Further study is needed to establish causality between anti-AT1R and graft failure and, thus, the importance of routine anti-AT1R monitoring and therapeutic targeting.


Assuntos
Autoanticorpos/sangue , Rejeição de Enxerto/imunologia , Sobrevivência de Enxerto , Transplante de Rim , Receptor Tipo 1 de Angiotensina/imunologia , Adulto , Autoanticorpos/imunologia , Biópsia , Estudos de Casos e Controles , Ensaio de Imunoadsorção Enzimática , Feminino , Seguimentos , Rejeição de Enxerto/sangue , Rejeição de Enxerto/diagnóstico , Rejeição de Enxerto/mortalidade , Antígenos HLA/imunologia , Humanos , Terapia de Imunossupressão , Nefropatias/sangue , Nefropatias/cirurgia , Masculino , Pessoa de Meia-Idade , Prognóstico , Taxa de Sobrevida , Transplante Homólogo
3.
Am J Transplant ; 7(4): 864-71, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17391129

RESUMO

Longitudinal studies were conducted over a five-year period for HLA antibodies on 493 sera tested from 54 kidney transplant patients. HLA single antigen beads were employed to establish donor specificity of the antibodies. Only 3 of 22 patients without antibodies rejected a graft in contrast to 17 out of 32 patients with posttransplant antibodies (p = 0.003). Using a serum creatinine value of 4.0 mg/dL as the cut-off for a failed graft, 4 of 22 patients without antibodies failed compared to 21 of 32 with antibodies (p = 0.0006). Among patients with donor-specific antibodies (DSA) 13 of 15 failed (p = 0.000004). Even among patients with non-donor specific antibodies (NDSA), 8 of 17 failed (p = 0.05). Among patients who could be identified as making de novo antibodies (since they developed antibodies while not having antibodies for more than six months after transplantation), 6 of 11 failed (p = 0.03). Sequential testing for HLA antibodies shows that antibodies appear prior to a rise in serum creatinine and subsequent graft failure. The very strong association between the production of HLA antibodies after transplantation and graft failure indicates the importance of monitoring for posttransplant HLA antibodies.


Assuntos
Antígenos HLA/imunologia , Isoanticorpos/imunologia , Transplante de Rim/imunologia , Adulto , Cadáver , Feminino , Sobrevivência de Enxerto/imunologia , Antígenos HLA-D/imunologia , Antígenos de Histocompatibilidade Classe I/imunologia , Humanos , Doadores Vivos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Doadores de Tecidos , Falha de Tratamento
4.
Clin Chem Lab Med ; 38(1): 33-9, 2000 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-10774959

RESUMO

Two-site immunoassay methods have become the standard technique for measurement of a wide variety of drugs, hormones, and cell proteins. One limitation of these methods is their susceptibility to interference from heterophilic antibodies present in the sera of some patients. Human anti-murine antibodies represent a common heterophile antibody that can bind to mouse immunoglobulin and as well as to immunoglobulin from other species. While the mechanism of human anti-murine antibody interference has been well characterized, the time course over which this interference occurs and the susceptibility of different immunoassay procedures to human anti-murine antibody interference from patients with human anti-murine antibody have not been as well described. We report on the time course of interference in assays for cardiac markers for two patients with human anti-murine antibodies. We measured creatine kinase MB isoenzyme (CKMB) and troponins I and T using three different vendors' immunoassay procedures. Our results demonstrate that assay interference due to human anti-murine antibody interference is a transient phenomenon. In one of our patients, human anti-murine antibody interference appeared suddenly, peaked approximately 9 days following its appearance, and gradually resolved over the next 3 weeks. In addition, we found that immunoassay methods from different vendors can show highly variable interference effects when human anti-murine antibody-containing specimens are analyzed.


Assuntos
Anticorpos Heterófilos/imunologia , Biomarcadores/análise , Cardiopatias/diagnóstico , Técnicas Imunoenzimáticas/métodos , Idoso , Animais , Constrição Patológica/sangue , Constrição Patológica/enzimologia , Constrição Patológica/imunologia , Endarterectomia , Feminino , Cardiopatias/sangue , Cardiopatias/imunologia , Humanos , Masculino , Camundongos , Reprodutibilidade dos Testes , Síncope/sangue , Síncope/enzimologia , Síncope/imunologia , Fatores de Tempo
5.
Clin Chem Lab Med ; 37(4): 453-64, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10369118

RESUMO

The use of hemoglobin-based oxygen carrier solutions in patients requiring blood transfusion will necessitate that clinical laboratories have mechanisms in place to evaluate the potential interference effect of these substances on testing methods. Because these oxygen carrier solutions contain acellular hemoglobin, but do not contain many of the intracellular enzymes and ions present in erythrocytes, interference effects from blood substitutes may be quite different when compared to in vivo or in vitro lysis of erythrocytes. We evaluated the potential interference effect of Diaspirin Cross-linked Hemoglobin on 29 different clinical laboratory analytes. Various combinations of these analytes were tested using the Hitachi 747 and 911 systems, a Beckman CX3, an Abbott AxSym, a Bayer Immuno I, and a Dade ACA IV; a total of 60 analyte/instrument combinations. We used the method of multiple regression analysis to classify interferences as analyte-dependent, analyte-independent, or a combination of the first two types. The presence of clinically significant test interference was derived by using the criteria for maximum allowable error specified in the Clinical Laboratory Improvement Amendments of 1988. Using these criteria, we found significant interference from Diaspirin Cross-linked Hemoglobin with 13 of 29 analytes tested. Interference was noted with the Hitachi 747 and 911 methods for albumin, alkaline phosphatase, total and conjugated bilirubin, cholesterol, total carbon dioxide, iron, lactate dehydrogenase, magnesium, total protein, and triglyceride. In addition, Diaspirin Cross-linked Hemoglobin interfered with measurement of L-lactate using the ACA IV and minor interference was noted with glucose measured using the Beckman CX3. Data from the interference studies was graphically displayed in the form of interference plots. These plots show the maximum allowable test error, due to Diaspirin Cross-linked Hemoglobin, as a function of analyte and interferent concentrations. Evaluation of the potential interference effect of hemoglobin-based oxygen carrier solutions with use of multiple regression analysis and graphical display of the resultant data in the form of interference plots allows for more reliable reporting of test results from specimens containing these products.


Assuntos
Aspirina/análogos & derivados , Análise Química do Sangue/métodos , Hemoglobinas/análise , Análise de Regressão , Aspirina/análise , Bilirrubina/análise , Relação Dose-Resposta a Droga , Humanos
6.
Adv Ren Replace Ther ; 2(4): 349-61, 1995 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8591126

RESUMO

The case of a patient who was noted to be malnourished but improved after his dialysis dose was increased is presented. This case and the discussion that follows emphasize the importance of proactively monitoring peritoneal dialysis adequacy and nutritional intake, supporting the notion that the dose of peritoneal dialysis is a major determinant of appetite and, consequently, of nutritional status. In the clinical setting, this influence is best indicated by changes in the serum albumin level and ultimately in long-term patient survival. The case discussion reviews the major principles and supporting literature, describing how we target peritoneal dialysis delivery and optimize nutritional status in an effort to reduce morbidity and mortality.


Assuntos
Glomerulonefrite por IGA/terapia , Diálise Peritoneal Ambulatorial Contínua , Adulto , Glomerulonefrite por IGA/fisiopatologia , Humanos , Masculino , Estado Nutricional , Diálise Peritoneal Ambulatorial Contínua/efeitos adversos , Ureia/metabolismo
7.
J Chromatogr B Biomed Appl ; 655(2): 213-23, 1994 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-8081467

RESUMO

A rapid analytical method which is of practical use for the identification and quantitation of drugs of abuse in urine using HPLC with a diode-array detection is described. Because the method utilizes mathematical resolution of partially resolved peaks, greatly simplified sample preparation procedures and very short run times can be used. The generalized rank annihilation method (GRAM) is used to eliminate response due to unknown background peaks and separate partially resolved peaks. An optimized gradient elution program was found for which morphine, phenylpropanolamine, ephedrine, benzoylecgonine, lidocaine, cocaine, diphenhydramine, nortriptyline, norpropoxyphene, nordiazepam, codeine, D-amphetamine, meperidine, and amitriptyline elute from the HPLC column in less than 8.5 min. A commercially available system for HPLC analysis of drugs of abuse is currently available, however, the commercially available system takes 21 min to complete its analysis. Two modified sample pre-treatment methods were also developed to simplify sample treatment procedures substantially. In this paper, The GRAM technique is shown to be extremely powerful in identifying drugs of abuse from large overlapping peaks.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Drogas Ilícitas/urina , Detecção do Abuso de Substâncias/métodos , Humanos , Matemática , Espectrofotometria Ultravioleta , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...