Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Hip Int ; 33(5): 872-879, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36314413

RESUMO

BACKGROUND: Elevated serum chrome (sCr) and cobalt (sCo) concentrations are associated with local tissue adverse reactions to metal debris following metal-on-metal hip resurfacing (MoM-HR). Serum metal ions <2 µg/l are probably of little clinical relevance and a pragmatic "safe" threshold <5 µg/l has been suggested.The primary aim of this study was to evaluate if a careful selection of patients combined with optimal implant positioning could eliminate cases with "unsafe" serum metal ion levels. A secondary aim was to study the association between different risk factors and having Co and/or Cr levels >5 µg/l. PATIENTS AND METHODS: This is a retrospective, single-institution cohort study of 410 consecutive patients operated on with a Birmingham Hip Resurfacing (BHR) implant between 2001 and 2014. 288 of these had a unilateral MoM-HR, pelvic and true lateral radiographs, and a related sCo and sCr sample, and were included in the final analysis. They were allocated to either a presumed "optimal group" consisting of only men aged <60 years old, with femoral head component >48 mm diameter, and with a cup positioned within Lewinnek's safe zones, or a "suboptimal group" consisting of the remaining patients. Fisher's exact test and multiple logistic regression analyses were performed. RESULTS: In the optimal group 48% (47/97) had serum metal ions >2 µg/l and 8% (8/97) >5 µg/l compared to 61% (116/191) and 18% (34/191) in the suboptimal group, p = 0.059 and p = 0.034 respectively. Acetabular cups with an anteversion <5 degrees had the highest odds ratio, 6.5 (95% CI, 3.0-14.3), of having sCo and sCr concentrations exceeding 5 µg/l. CONCLUSIONS: A well oriented BHR acetabular component in a presumably "optimal" patient reduces the risk of having elevated serum metal ions but does not eliminate it. Insufficient cup anteversion seems to be the strongest associated factor of elevated serum metals.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Masculino , Humanos , Pessoa de Meia-Idade , Cobalto , Artroplastia de Quadril/efeitos adversos , Seleção de Pacientes , Estudos de Coortes , Estudos Retrospectivos , Próteses Articulares Metal-Metal/efeitos adversos , Cromo , Metais , Prótese de Quadril/efeitos adversos , Íons , Desenho de Prótese
2.
BMJ Open ; 12(2): e047500, 2022 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-35115346

RESUMO

INTRODUCTION: There is controversy regarding the importance of air-transmitted infections for surgical site infections (SSIs) after orthopaedic surgery. Research has been hindered by both the inability in blinding the exposure, and by the need for recruiting large enough cohorts. The aim of this study is to investigate whether using a new form of air purifier using plasma air purification (PAP) in operating rooms (ORs) lowers the SSI rate or not. METHODS AND ANALYSIS: Multicentre, double-blind, cluster-randomised, placebo-controlled trial conducted at seven hospitals in 2017-2022. All patients that undergo orthopaedic surgery for minimum 30 min are included. Intervention group: patients operated in OR with PAP devices turned on. CONTROL GROUP: patients operated in OR with PAP devices turned off. Randomisation: each OR will be randomised in periods of 4 weeks, 6 weeks or 8 weeks to either have the devices on or off. PRIMARY OUTCOME: any SSI postoperatively defined as a composite endpoint of any of the following: use of isoxazolylpenicillin, clindamycin or rifampicin for 2 days or more, International Classification of Diseases codes or Nordic Medico-Statistical Committee codes indicating postoperative infection. In a second step, we will perform a chart review on those patients with positive indicators of SSI to further validate the outcome. Secondary outcomes are described in the Methods section. Power: we assume an SSI rate of 2%, an SSI reduction rate of 25% and we need approximately 45 000 patients to attain a power of 80% at a significance level of 0.05. ETHICS AND DISSEMINATION: The study is approved by the Swedish Ethical Review Authority. The interim analysis results from the study will be presented only to the researchers involved unless the study thereafter is interrupted for whatever reason. Publication in a medical journal will be presented after inclusion of the last patient. TRIAL REGISTRATION NUMBER: NCT02695368.


Assuntos
Procedimentos Ortopédicos , Método Duplo-Cego , Humanos , Incidência , Procedimentos Ortopédicos/efeitos adversos , Ensaios Clínicos Controlados Aleatórios como Assunto , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/prevenção & controle
3.
Nucl Med Commun ; 43(2): 193-200, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34678830

RESUMO

PURPOSE: The aim of this study was to compare 99mTc-HMPAO-WBC-SPECT/CT combined with 99mTc-nanocollloid SPECT/CT and 18F-FDG-WBC-PET/CT combined with 99mTc-Nanocollloid SPECT/CT for the diagnosis and treatment evaluation of chronic prosthetic joint infection (PJI). METHODS: Patients with suspected chronic PJI were examined with 99mTc-HMPAO-WBC SPECT/CT, 18F-FDG-WBC PET/CT, and 99mTc-nanocolloid SPECT/CT (to visualize bone marrow). The location and patterns of uptake were noted and compared between the two leukocyte examinations. Both leukocyte examinations were evaluated visually for infection. The PET examinations were also evaluated semiquantitatively. Chronic PJI was verified clinically by microbial culture and successfully treated PJI was confirmed by 12 months symptom-free follow-up after cessation of antibiotics. RESULTS: Nineteen patients were included with 10 hip prostheses and nine knee prostheses. Fourteen were diagnosed with chronic PJI and five with successfully treated PJI. The sensitivity of visual evaluation of 99mTc-WBC-HMPAO SPECT/CT for all joints was 0.31 and for 18F-FDG-WBC PET/CT 0.38. The specificity was 0.80 and 0.83, respectively. All patients with a true-positive SPECT examination had a false-negative PET examination and vice versa. Semiquantitative evaluation of the hips gave an area under the curve of 0.905 using the iliac crest as the background. Semiquantitative evaluation of the knees did not produce significant results. CONCLUSION: This pilot study showed no difference in the sensitivity or specificity of 99mTc-HMPAO-WBC SPECT/CT and 18F-FDG-WBC PET/CT when combined with 99mTc-nanocollloid SPECT/CT in the diagnosis or treatment evaluation of suspected late chronic PJI.


Assuntos
Tecnécio Tc 99m Exametazima
4.
Nucl Med Commun ; 42(7): 719-724, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-33741868

RESUMO

BACKGROUND: Both dual time-point 99mTc-hexamethylpropylene amine oxime (HMPAO)-leukocyte scintigraphy and dual-tracer 99mTc-HMPAO-leukocyte scintigraphy (with the addition of 99mTc-nanocolloid bone marrow scintigraphy) have been used to diagnose prosthetic joint infection (PJI). A treatment evaluation of persistent PJI using these imaging protocols has yet to be presented. OBJECTIVE: The purpose of this study was to compare the accuracy of dual time-point 99mTc-HMPAO-leukocyte scintigraphy to the dual-tracer alternative of single time-point 99mTc-HMPAO-leukocyte scintigraphy or single-photon emission computed tomography/computed tomography (SPECT/CT) combined with a 99mTc-nanocolloid bone marrow scintigraphy or SPECT/CT, for treatment evaluation of PJI. MATERIAL AND METHODS: Thirty-one PJI patients under antibiotic treatment were included in this retrospective study. Examinations were organized into three settings. Setting one used dual time-point approach with delayed (2 h) and late (24 h) planar 99mTc-HMPAO-leukocyte scintigraphy, including both visual and semiquantitative analysis. Setting two used delayed (2 h) planar 99mTc-HMPAO-leukocyte scintigraphy combined with 99mTc-nanocolloid bone marrow scintigraphy and for setting three SPECT/CT replaced planar imaging. RESULTS: Accuracy was 0.68 for visual evaluation and 0.55 for semiquantitative evaluation of setting one; 0.71 for setting two; and 0.68 for setting three. Sensitivity was 0.54 for visual evaluation and 0.31 for semiquantitative evaluation of setting one; 0.38 for setting two; and 0.46 for setting three. Specificity was 0.78 for visual evaluation and 0.72 for semiquantitative evaluation of setting one; 0.94 for setting two; and 0.83 for setting three. CONCLUSION: No significant difference in accuracy, sensitivity, or specificity between the approaches for treatment evaluation of suspected persistent PJI in the hip or knee was observed.


Assuntos
Infecções Relacionadas à Prótese , Adulto , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tecnécio Tc 99m Exametazima , Tomografia Computadorizada de Emissão de Fóton Único
5.
Q J Nucl Med Mol Imaging ; 64(1): 85-95, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31140233

RESUMO

BACKGROUND: To investigate the sensitivity and specificity of 99mTc-HMPAO-leukocyte imaging in evaluating therapy result in patients with prosthetic joint infection (PJI) and in diagnosing suspected chronic PJI. METHODS: Sixty-two patients (63 joints) with microbiologically verified PJI were examined by leukocyte imaging to evaluate therapy result during or at the end of antibiotic treatment or if the patient had a chronic PJI after treatment. Group 1 consisted of 49 patients with on-going or within less than 14 days of ending antibiotic treatment examined to evaluate response. Group 2 consisted of 13 patients examined after completed treatment on suspicion of chronic PJI with no or recently initiated renewed antibiotic treatment. This study applied a combination of different imaging approaches of 99mTc-HMPAO-leukocyte scintigraphy: delayed and late planar images, bone marrow imaging and SPECT/CT imaging. All joints were examined with at least two of the approaches and 53 joints with all three approaches. The report was based on the combined results of the approaches used. A chronic PJI was confirmed with a positive microbiological culture. A cured infection was confirmed with either a negative culture or at least 24 months antibiotic-free follow-up with no relapse. RESULTS: In the therapy evaluation group sensitivity was 0.57 and specificity was 0.81. In the suspected chronic infection group sensitivity was 1.00 and specificity 0.91. CONCLUSIONS: 99mTc-HMPAO-leukocyte imaging appears to be an accurate method to diagnose or exclude chronic PJI, but cannot be recommended for therapy evaluation of PJI in patients with on-going antibiotic treatment.


Assuntos
Artropatias/diagnóstico por imagem , Artropatias/tratamento farmacológico , Leucócitos/citologia , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/tratamento farmacológico , Tecnécio Tc 99m Exametazima , Idoso , Antibacterianos/uso terapêutico , Doença Crônica , Estudos de Coortes , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Estudos Retrospectivos , Resultado do Tratamento
6.
Acta Orthop ; 90(4): 318-323, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30997847

RESUMO

Background and purpose - The theoretical mechanical advantages of metal-on-metal hip resurfacing (MoM-HR) compared with conventional total hip arthroplasty (THA) have been questioned. Studies including measures of patient-reported function, physical activity, or health-related quality of life have been sparse. We compared patient-reported outcomes in MoM-HR patients with a matched group of patients with conventional THA at 7 years post-surgery. Patients and methods - Patients and patient data were retrieved from the Swedish Hip Arthroplasty Register. The case group, consisting of 363 patients with MoM-HR, was matched 1:1 with a control group, consisting of patients with a conventional THA. Patients were sent a postal patient-reported outcome measures (PROM) questionnaire including the Hip Disability and Osteoarthritis Outcome Score (HOOS), EQ-5D, and VAS pain. We used multivariable linear regression analyses to investigate the influence of prosthesis type. Results - 569 patients (78%) returned the questionnaire with complete responses (299 MoM-HRs and 270 conventional THAs). MoM-HR was associated with better scores in HOOS function of daily living (4 percentage units) and HOOS function in sport and recreation (8 percentage units) subscales. Type of prosthesis did not influence HOOS quality of life, HOOS pain, HOOS symptoms, EQ-5D index, hip pain, or satisfaction as measured with visual analog scales. Interpretation - At mean 7 years post-surgery, patients with hip resurfacing had somewhat better self-reported hip function than patients with conventional THA. The largest difference between groups was seen in the presumed most demanding subscale, i.e., function in sport and recreation.


Assuntos
Artroplastia de Quadril/métodos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/estatística & dados numéricos , Estudos de Casos e Controles , Feminino , Articulação do Quadril/cirurgia , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/cirurgia , Medidas de Resultados Relatados pelo Paciente , Qualidade de Vida , Recuperação de Função Fisiológica , Sistema de Registros/estatística & dados numéricos , Inquéritos e Questionários
7.
J Orthop Surg Res ; 7: 17, 2012 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-22533964

RESUMO

BACKGROUND: Less invasive approaches for hip arthroplasty have been developed in order to decrease traumatisation of soft tissue and shorten hospital stay. However, the benefits with a new technique can be at the expense of a new panorama of problems. This manuscript describes, with emphasis on postoperative complications, our experience from the first 200 cases of unilateral hip replacement using the direct anterior minimally invasive (MIS) approach. METHODS: A straight incision in front of the greater trochanter was used and the tensor muscle was approached subfascially and retracted laterally. The joint was opened and the femoral head was removed. Usually excellent acetabular exposure was obtained. In order to get access to the proximal femur, the hip capsule was released posterolaterally so that the femur could be lifted using a special retractor behind the tip of the trochanter. After insertion of the prostheses, the wound was closed using running sutures in the fascia overlying the tensor, sub- and intracutaneously. RESULTS: There was a small influence of BMI on the duration of surgery, and obese patients tended to have the cup positioned at a higher degree of deviation. There were in total 17 complications of which 5 necessitated revision surgery; 3 peroperative femoral fractures and 2 dislocations. Another 4 dislocations were treated with closed reduction and did not recur. 3 cases of nerve injury were noted, all resolved within 12 months. Three cases of DVT were diagnosed as well as 2 cases of postoperative infection; none of these led to chronic disability. CONCLUSIONS: The technique is perhaps more technically demanding than the lateral approaches used today due to the somewhat limited surgical exposure. Morbidly obese or very muscular patients as well as patients with a short femoral neck or acetabular protrusion can represent particular problems. Our results indicate that there are certain risks when adopting this procedure but the complications noted are avoidable.


Assuntos
Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Articulação do Quadril/cirurgia , Complicações Pós-Operatórias/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fraturas do Fêmur/etiologia , Nervo Femoral/lesões , Luxação do Quadril/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Nervo Fibular/lesões , Reoperação , Estudos Retrospectivos , Infecção da Ferida Cirúrgica/etiologia , Resultado do Tratamento , Trombose Venosa/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...