Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
S Afr Med J ; 79(7): 364-6, 1991 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-2014458

RESUMO

Over the 10-year period January 1976-December 1985, 446 patients with histologically verified adenocarcinoma of the stomach were treated at Tygerberg Hospital. Coloured patients made up 63.4% of the study population and a significant increase in the annual proportion of this group was observed. Coloured men comprised 47.6% of the total group. The mean age of white and coloured patients differed significantly (68.9 v. 56.5; P less than 0.001). The symptom complex was essentially similar in the two racial groups and in general the character of the symptoms had no bearing on the prevalence of resection. Although antral tumours were most common in whites and in coloureds, there was a significant increase in tumours located in the fundus in whites. The resection rate remained unchanged over the 10-year period. Only 4 cases of early gastric cancer were detected during this period without any signs of an increased yield of early lesions over time. This audit revealed no beneficial changes over time, which is in stark contrast with reports from Japan regarding the proportion of curable lesions.


Assuntos
Adenocarcinoma/epidemiologia , Neoplasias Gástricas/epidemiologia , Adenocarcinoma/cirurgia , Adulto , Negro ou Afro-Americano , Idoso , Idoso de 80 Anos ou mais , População Negra , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , África do Sul/epidemiologia , Neoplasias Gástricas/cirurgia , População Branca
3.
J Antimicrob Chemother ; 25(4): 665-72, 1990 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-2190973

RESUMO

The accuracy and reproducibility of two different Syva EMIT and Abbot TDx instruments for the determination of gentamicin were assessed. A series of spiked standard serum samples containing gentamicin in concentrations ranging from 0.88-17.82 mg/l were used for this purpose. Both TDx systems evaluated had excellent reproducibility but overestimated gentamicin levels in the clinically important concentration range in an apparent concentration-dependent way by at least 5 and 10%, respectively. In addition both these systems exhibited considerable carryover effects when high concentration gentamicin samples (17.82 mg/l) were alternated with serum blanks. Average gentamicin levels determined by the EMIT systems were much closer to the target values, especially those of EMIT-A, than those measured by the TDx-systems. The reproducibility, as measured by the coefficient of variation (CV), of the semi-automated EMIT systems over the entire concentration range investigated was about half that of the TDx-systems. No carryover effects were observed with the two EMIT-systems. This study has shown that the accuracy and reproducibility of both assay methods vary considerably over the clinically important gentamicin concentration range. In addition there may be a large variation between instruments of the same system especially in the critical trough region for gentamicin.


Assuntos
Polarização de Fluorescência/instrumentação , Gentamicinas/sangue , Técnicas Imunoenzimáticas/instrumentação , Padrões de Referência , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...