Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Noise Health ; 10(41): 99-104, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19075456

RESUMO

While no legal rules or regulations exist in Germany, voluntary measures were introduced to achieve a reduction of sound pressure levels in discotheques to levels below 100 dB(A). To evaluate the current levels in Bavarian discotheques and to find out whether these voluntary measures ensured compliance with the recommended limits, sound pressure levels were measured in 20 Bavarian discotheques between 11 p.m. and 2 a.m. With respect to the equivalent continuous A-weighted sound pressure level for each 30-minute period (L Aeq,30min ), only 4/20 discotheques remained below the limit of 100 dB(A) in all time periods. Ten discotheques had sound pressure levels below 100 dB(A) for the total measurement period (L Aeq,180min ). None of the evaluated factors (weekday, size, estimated age of attendees, the use of voluntary measures such as participation of disc jockeys in a tutorial, or the availability of a sound level meter for the DJs) was significantly associated with the maximal L Aeq, 30min . Thus, the introduction of voluntary measures was not sufficient to ensure compliance with the recommended limits of sound pressure levels.


Assuntos
Perda Auditiva Provocada por Ruído/prevenção & controle , Música , Ruído/prevenção & controle , Adulto , Alemanha , Fidelidade a Diretrizes , Perda Auditiva Provocada por Ruído/etiologia , Humanos , Ruído/efeitos adversos , Restaurantes/normas , Espectrografia do Som , Programas Voluntários , Adulto Jovem
2.
Bioelectromagnetics ; 27(1): 77-81, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16304690

RESUMO

The aim of our study was to test the feasibility and reliability of personal dosimetry. Twenty-four hour exposure assessment was carried out in 42 children, 57 adolescents, and 64 adults using the Maschek dosimeter prototype. Self-reported exposure to mobile phone frequencies were compared with the dosimetry results. In addition, dosimetry readings of the Maschek device and those of the Antennessa DSP-090 were compared in 40 subjects. Self-reported exposures were not associated with dosimetry readings. The measurement results of the two dosimeters were in moderate agreement (r(Spearman) = 0.35; P = .03). Personal dosimetry for exposure to mobile phone base station might be feasible in epidemiologic studies. However, the consistency seems to be moderate.


Assuntos
Telefone Celular , Radiometria/instrumentação , Adolescente , Adulto , Criança , Exposição Ambiental , Métodos Epidemiológicos , Estudos de Viabilidade , Humanos , Ondas de Rádio/efeitos adversos , Radiometria/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...