Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-18024246

RESUMO

The analysis of biomarkers from exhaled breath condensate (EBC) is a non-invasive but challenging method for the detection of pulmonary diseases. The amino acids L-proline (Pro) and l-tyrosine (Tyr) are precursors for two important metabolites, trans-L-4-hydroxyproline (trans-L-4-hydroxypyrrolidin-2-carboxylic acid, t-Hyp) and nitrotyrosine (NT). Whereas t-Hyp is supposed to be a biomarker for lung fibrosis, NT is a promising biomarker for inflammation in airway diseases. Analysis of EBC requires extremely sensitive methods, because the epithelial lining fluid of the lung and upper airway is highly diluted in EBC. The high intra- and interindividual variation of this dilution implicates additional problems for sample collection and the interpretation of EBC results. Hence, our aim was to work out a method that would compensate for these possible dilution effects. We have developed a new, reliable and very sensitive method for the simultaneous determination of Pro, t-Hyp, Tyr and NT from EBC. Except for t-Hyp, we used labelled internal standards (IS) L-proline (13)C(5), (15)N (Pro (13)C(5)), L-tyrosine-(13)C(9) (Tyr (13)C(9)), (13)C(9)-3-nitrotyrosine (NT(13)C(9)), IS for t-Hyp was cis-4-hydroxy-L-proline, which were added to the samples before they were lyophilised for concentration. For the separation of the analytes we used hydrophilic interaction liquid chromatography (HILIC), coupled to tandem-mass-spectrometry (MS/MS). The limit of detection (LOD) was 0.5 microg/l for Pro and Tyr and 5 ng/l for t-Hyp and NT. The relative standard deviation (RSD) of the precision from day to day was between 2.6 and 8.0% at spiked concentrations between 4 and 25 microg/l for Pro and between 4.2 and 7.3% for Tyr. The RSD of the precision from day to day was between 7.5 and 13.2% at spiked concentrations between 40 and 250 ng/l for t-Hyp and between 3.5 and 8.2% for NT. The method was established using 27 healthy subjects with a median age of 46 years. Concentrations ranged from 2.8 to 51.9 microg/l for Pro, from <5 to 516.5 ng/l for t-Hyp, from 2.4 to 99.1 for Tyr and for NT concentration ranged between <5 and 1686.5 ng/l.


Assuntos
Testes Respiratórios/métodos , Cromatografia Líquida/métodos , Hidroxiprolina/análise , Prolina/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Tirosina/análogos & derivados , Tirosina/análise , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fibrose Pulmonar/diagnóstico , Reprodutibilidade dos Testes
2.
Anal Bioanal Chem ; 387(8): 2783-91, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17318517

RESUMO

Analysis of biomarkers in exhaled breath condensate (EBC) is a non-invasive method for investigating the effects of different diseases or exposures, on the lungs and airways. N(epsilon)-carboxymethyllysine (CML) is an important biomarker of advanced glycation end products (AGEs). A method has been developed for simultaneous determination of CML and its precursor, the amino acid lysine, in exhaled breath condensate (EBC). After addition of labelled internal standards (d-4-CML; d-4-lysine), the EBC was concentrated by freeze-drying. Separation and detection of the analytes were performed by hydrophilic-ion liquid chromatography coupled with tandem mass-spectrometric detection (HILIC-MS-MS). The limits of quantification were 10 pg mL(-1) EBC and 0.5 ng mL(-1) EBC for CML and lysine, respectively. The relative standard deviation of the within-series precision was between 2.8 and 7.8% at spiked concentrations between 40 and 200 pg mL(-1) for CML and between 6 and 20 ng mL(-1) for lysine. Accuracy for the analytes ranged between 89.5 and 133%. The method was used for the analysis of EBC samples from ten healthy persons from the general population and ten persons receiving dialysis. CML and lysine were detected in all EBC samples with median values of 19 pg mL(-1) CML and 11.9 ng mL(-1) lysine in EBC of healthy persons and 25 pg mL(-1) CML and 9.5 ng mL(-1) lysine in EBC of dialysis patients.


Assuntos
Testes Respiratórios , Cromatografia Líquida/métodos , Lisina/análogos & derivados , Lisina/análise , Espectrometria de Massas em Tandem/métodos , Adulto , Calibragem , Feminino , Humanos , Isótopos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização por Electrospray
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...